Extron electronic MTP U R RSA SEQ manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Extron electronic MTP U R RSA SEQ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Extron electronic MTP U R RSA SEQ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Extron electronic MTP U R RSA SEQ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Extron electronic MTP U R RSA SEQ should contain:
- informations concerning technical data of Extron electronic MTP U R RSA SEQ
- name of the manufacturer and a year of construction of the Extron electronic MTP U R RSA SEQ item
- rules of operation, control and maintenance of the Extron electronic MTP U R RSA SEQ item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Extron electronic MTP U R RSA SEQ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Extron electronic MTP U R RSA SEQ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Extron electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Extron electronic MTP U R RSA SEQ.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Extron electronic MTP U R RSA SEQ item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User ’s Guide 68-1367-01 Rev . B 09 08 MTP U R RSA SEQ, MTP U R RS SEQ, MTP U R RS, and MTP U R A Mini T wisted Pair Universal Receivers[...]

  • Page 2

    Pr ecautions This symbol is intended to alert the user of important opera ting and mai ntena nce (ser vicin g) instr uctio ns in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock. Caution Re[...]

  • Page 3

    Pr ecautions 安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 注意 阅读说明书 • 用户使用该设备前必须阅读并理 解所有安全和使用说明。 保存说明书 • 用户应保?[...]

  • Page 4

    [...]

  • Page 5

    MTPT U R Series • T able of Contents About this Manual ................................................................... 2 About the MTP Universal Receiver s ............................... 2 TP cable advantages ................................................................. 4 T ransmission distance ...........................................[...]

  • Page 6

    MTP U R Series • Introduction About this Manual This manual details the installation and operation of the Extron MTP U R series of mini twisted pair universal r eceivers. • MTP U R RSA SEQ mini twisted pair receiver with RS-232, audio, and skew equalization • MTP U R RS SEQ mini twisted pair r eceiver with RS-232 and skew equalization • MTP[...]

  • Page 7

    MTP U R Series • Introduction The MTP U Rs ar e a part of the Extron V ersaT ools ® line of basic distribution amplifiers, switchers, transmitters, receivers, and associated video accessories. The MTP U R models r eceive signals (high resolution RGB video, bi-level or tri-level component video, S-video and composite video) on an RJ-45 connector[...]

  • Page 8

    Introduction, cont’d MTP U R Series • Introduction TP cable advantages T wisted pair cable is much smaller , lighter , more flexible, and less expensive than coaxial cable. These TP pr oducts make cable runs simpler and less cumbersome and termination with RJ-45 connectors is simple, quick, and economical. T ransmission distance The maximum di[...]

  • Page 9

    MTP U R Series • Introduction 5 JMP1 JMP3 JMP2 Default settings as viewed from rear N The transmitter and receiver ar e designed for and perform best with Extron Enhanced Skew-Fr ee A/V cable terminated in accordance with the TIA/EIA T 568 A wiring standard. CA T 5 cables are acceptable but less preferable. W e also recommend the use of pre-termi[...]

  • Page 10

    Introduction, cont’d MTP U R Series • Introduction 6 6 . If applicable, reinstall the r eceiver and reconnect all cables. N Jumper 1 should be set to uni-directional when an MTP DA is installed as part of the system to avoid any RS-232 /Audio detection issues. When an MTP U R series receiver is used with an MTPX Matrix Switcher , it should be s[...]

  • Page 11

    MTP U R Series • Introduction UTP UTP MTP U R RSA SEQ Vi d S-Video YUV RG B RS-232 Audio Vi d S-Video YUV RG B RS-232 Audio Plasma/LCD MTP U R RSA SEQ Projector UTP UTP UTP UTP Source MTP Tr ansmitters MTPX Matrix Switcher MTP U R Receiv ers Display Devic es MTP T SV A MTP T AV MTP T 15HD RS Control Sy stem #1 #2 #1 #4 #3 #2 RS-232 OUTPUT INSERT [...]

  • Page 12

    MTP U R Series • Installation Installation Installation C Installation and service must be performed by authorized personnel only . The 1U high, quarter rack width, MTP U R r eceiver can be mounted on a rack shelf, to a rack without a shelf, under a desk or tabletop, or on a projector bracket. UL guidelines for rack mou nted devices The following[...]

  • Page 13

    MTP U R Series • Installation 9 • RSU 129, Standard universal 1U rack shelf kit (part # 60-190-01 ) • RSB 129, Basic universal 1U rack shelf (part # 60-604-02 ) On the standard rack shelf, the MTP U R mounts in one of four locations to the rear of the rack or in one of four locations to the front of the rack. (2) 4-40 x 3/16" Screws Use [...]

  • Page 14

    MTP U R Series • Installation Installation, cont’d 10 N Fxtron r ecommends where more than one shelf is requir ed, rack mount shelves are installed at least 1U apart, to allow for air flow and proper cooling between the shelves. 3 . Install false faceplate(s) or other unit(s) to the rack shelf. 4. Mount the shelf into the rack. Back of the rac[...]

  • Page 15

    MTP U R Series • Installation 11 MAV SERIES AV MATRIX SWITCHE R I/O A U D A U D IO S E T U P P R E S E T V ID IR +dB -dB E N T E R 2 7 6 5 2 4 1 INPUTS OUTPUTS 8 3 1 8 6 5 4 3 7 MTP SERIES Rear F ront Figure 11 — T ypical back of the rack installations Furniture or projector mounting Use the optional mounting kit (MBU 123, furniture, part # 70-[...]

  • Page 16

    MTP U R Series • Installation Installation, cont’d 12 1 . Remove the feet from the bottom of the MTP , if they ar e installed. 2 . Attach the mounting brackets to the MTP with the machine screws pr ovided. 3 . For furniture mounting , hold the MTP with the attached brackets against the mounting surface. Mark the bracket screw hole locations on [...]

  • Page 17

    MTP U R Series • Installation 13 Connections and Settings Rear panel connectors and features for the MTP U R series of receivers ar e shown below . INPUT 1 RGB POWER 12V 0.5A MAX L MONO AUDIO R VID Y/C B-Y Y R-Y OUTPUTS RS-232 Tx Rx SP ARE INPUT 1 POWER 12V 0.5A MAX RGB VID Y/C OUTPUTS MTP U R A L MONO AUDIO R MTP U R RSA SEQ MTP U R A 1 2 4 6 8 [...]

  • Page 18

    MTP U R Series • Installation Installation, cont’d 14 a Power connector — Plug the included external 12 VDC power supply into this 2-pole captive screw connector . See “Power supply wiring” to wire the connector . b Input 1 connector — Connect one end of the cable from the transmitter . See “TP cable termination” to wir e the RJ-45 [...]

  • Page 19

    MTP U R Series • Installation 15 g RS-232 connector — Connect a serial communications port to this 3.5 mm, 5-pole captive screw connector for bidir ectional RS-232 communication. W ire the connector as shown below . Ground Tx Rx Gnd Receive Tr ansmit Connected RS-232 Device Pins MTP Pins Spare Spare Figure 14 — Pin assignments for RS-232 wiri[...]

  • Page 20

    MTP U R Series • Installation Installation, cont’d 16 Power supply wiring N This product is intended to be supplied by a UL Listed power supply and output rated at 12 VDC, 2A. W ire the supplied male power connector (plug) as in gur e 16. Po wer Supply Output Cord Captive Screw Connector SECTION A– A Ridges Smooth A A Tie Wrap 3" 16 ([...]

  • Page 21

    MTP U R Series • Installation 17 TP cable termination N RJ-45 termination must comply with TIA/EIA T 568A or TIA/EIA T 568B wiring standards for all connections. Figure 17 details the r ecommended termination of TP cables with RJ-45 connectors in accordance with the TIA/EIA T 568A or TIA/EIA T 568B wiring standards. Either standar d can be used w[...]

  • Page 22

    MTP U R Series • Installation Installation, cont’d 18 Front Panel Contr ols and Indicators Front panel featur es on the MTP U R receivers ar e shown below . RGB DELA Y PEAKING LEVEL MTP U R RSA SEQ R G B SEL ECT ADJUST SIGNAL AU DI O RS-232 VID Y/C YU V RGB RGB DELA Y PEAKING LEVEL MTP U R RS SEQ R G B SEL ECT ADJUST SIGNAL VID Y/C YU V RGB MTP[...]

  • Page 23

    MTP U R Series • Installation 19 a Power LED — Indicates power is applied to the MTP . b Signal LEDs — The appropriate LED lights when its signal type is present and auto-detected. The signal types indicated ar e either composite video, Y/C, YUV , or RGB. c Select button (SEQ models only) — This recessed button selects the red, gr een, or b[...]

  • Page 24

    MTP U R Series • Installation Installation, cont’d 20 The maximum setting (at the clockwise limit) provides 100% peaking. Adjust this control while viewing the displayed image to obtain the optimum picture sharpness. See “Peaking and Level Adjustment” section below for details. N T o avoid possible video loss due to errors in the video form[...]

  • Page 25

    MTP U R Series • Installation 21 N Since this product differs fr om the standard MTP receiver by its ability to auto detect the video format received, based on the video signal quality , it requir es a reasonable adjusted signal for both level and peaking. There is some mar gin for over peaking, but if too much over peaking occurs the signal may [...]

  • Page 26

    MTP U R Series • Installation 22 Installation, cont’d N A 2-nanosecond (ns) adjustment is very fine. Up to 10 ns of delay may be necessary before a change in the display is detectable. Maximum delay possible is 62 nanoseconds. c . Use a T weeker or other small screwdriver to pr ess the Select button one more time to save the most r ecent adjus[...]

  • Page 27

    Specications MTP U R Series • Specications 23 Specications Video Gain ................................................ Unity Video input Number/signal type ..................... 1 set of proprietary analog signals Connectors .................................... 1 female RJ-45 Video output Number/signal type ..................... 1 RGBHV [...]

  • Page 28

    MTP U R Series • Specications Specications, cont’d 24 THD + Noise ................................. 0.15% @ 1 kHz, 0.3% @ 20 kHz at nominal level S/N ................................................. >70 dB at maximum output (unweighted) Audio input — MTP U R RSA SEQ, MTP U R A — See MTP Series transmitters’ audio output speci[...]

  • Page 29

    MTP U R Series • Specications 25 N Pr otocol is mirrored between the transmitter and the r eceiver . Serial control pin configurations . Captive screw connectors: 1 = TX, 2 = RX, 3 = GND General External power supply ................. 100 V AC to 240 V AC, 50/60 Hz, external, autoswitchable; to 12 VDC, 2 A, regulated Power input requir ements[...]

  • Page 30

    MTP U R Series • Specications Specications, cont’d Part Numbers MTP receivers Receiver Part number MTP U R RSA SEQ receiver 60-869-01 MTP U R RS SEQ r eceiver 60-869-02 MTP U R A receiver 60-869-03 MTP U R RS r eceiver 60-869-04 Accessories Accessories Part number P/S 123 Multiple output 12 V power supply 60-814-01 19" 1U Universal R[...]

  • Page 31

    Extron’ s W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electr onics will, at its option, repair or replace said prod[...]

  • Page 32

    Ex tron US A - We st Headquar te rs + 80 0.6 33 .9 87 6 I nside U S A / C anad a On ly +1 .7 1 4.4 91 .1 50 0 +1 .7 1 4.4 91 .1 51 7 FA X Ex tron US A - East + 800 .6 33 .9 87 6 I nside U S A / C anad a On ly +1 .9 19 .8 63 .1 79 4 +1 .9 19 .8 63 .1 79 7 FA X Ex tron EM EA + 800 .3 98 7. 66 73 I nside E urop e On ly +3 1. 3 3.4 5 3. 404 0 +3 1. 3 3[...]