Go to page of
Similar user manuals
-
Dishwasher
Miele G 6730
100 pages 3.49 mb -
Dishwasher
Miele G 6735
100 pages 3.52 mb -
Heater
Cadel Moon
48 pages 20.49 mb -
Dishwasher
Miele G 7310
124 pages 3.58 mb -
Dishwasher
Miele G 7315
124 pages 3.58 mb -
Dishwasher
Miele G 7312
124 pages 3.58 mb -
Dishwasher
Miele G 7317
124 pages 3.58 mb -
Dishwasher
Miele G4820
96 pages 2.31 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of FCI 12-64B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FCI 12-64B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of FCI 12-64B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of FCI 12-64B should contain:
- informations concerning technical data of FCI 12-64B
- name of the manufacturer and a year of construction of the FCI 12-64B item
- rules of operation, control and maintenance of the FCI 12-64B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FCI 12-64B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FCI 12-64B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FCI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FCI 12-64B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the FCI 12-64B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
12-64B, 8-66B Inst allation, Operation and T roubleshooting Guide Document 06EN003322 Rev . - S tep 1. Pr e-Installation A. T o get the best results, the sensor should be mounted 20 pipe diameters downstream from any flow disturbance (valve, pipe elbow) and 10 pipe diameters upstream from any disturbance. 24 Hour Factory Service Hot Line: 1 (800) 8[...]
-
Page 2
Model 12-64/8-66 2 Doc. No. 06EN003322 Rev.- 12-64 Flow Switch and 8-66 Level Switch Installation and Outline Drawing S tep 3. W iring Pr eparation Before the instrument is opened to install the wiring, FCI recommends that the following ESD precautions be observed: Use a wrist band or heel strap with a 1 megohm resistor connected to ground. If the [...]
-
Page 3
Doc. No. 06EN003322 Rev. - 3 Model 12-64/8-66 INSTALLATION, OPERATION AND TROUBLESHOOTING GUIDE FLUID COMPONENTS INTL FCI recommends routing conduit to the enclosure. Below is a table to determine the wire size needed to route to the instrument. Connect the customer ’ s application (relays, lights, etc,.) to the terminal block switch points as re[...]
-
Page 4
Model 12-64/8-66 4 Doc. No. 06EN003322 Rev.- Adjustment With The Sensing Element Wet 1. Determine that the sensing element is wet. 2. Apply power to the instrument and allow 10 minutes for the sensing element to become active and stabilize. 3. Locate the potentiometer (R5) and the red LED on the control circuit. (See the picture on the previous pag[...]