Go to page of
Similar user manuals
-
Heat Pump
Fedders CH1048CBD3VF
4 pages 0.07 mb -
Heat Pump
Fedders CH18ABD1
8 pages 0.82 mb -
Heat Pump
Fedders CH1042CBD1VF
4 pages 0.07 mb -
Heat Pump
Fedders CH1060CBD4VF
4 pages 0.07 mb -
Heat Pump
Fedders CH36ACD1VF
6 pages 0.17 mb -
Heat Pump
Fedders CH60ACZ1VF
6 pages 0.17 mb -
Heat Pump
Fedders CH1048CBD1VF
4 pages 0.07 mb -
Heat Pump
Fedders C12
4 pages 0.07 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fedders CH18ABD1VF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fedders CH18ABD1VF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fedders CH18ABD1VF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fedders CH18ABD1VF should contain:
- informations concerning technical data of Fedders CH18ABD1VF
- name of the manufacturer and a year of construction of the Fedders CH18ABD1VF item
- rules of operation, control and maintenance of the Fedders CH18ABD1VF item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fedders CH18ABD1VF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fedders CH18ABD1VF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fedders service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fedders CH18ABD1VF.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fedders CH18ABD1VF item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Split S yst em H eat P ump 1 1 ⁄ 2 thru 5 T ons 208/230 V olt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 ⁄ 2 to 5 to ns Refrigerant Circuit: Factory installed biflow liquid line filter drier Long life c opper tubes, alumin um fins State-of-the-art compr essors Large, wr ap-around c oil surface Quality [...]
-
Page 2
P roduct Specifications 2 Specifications subject to change without notice. NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection. 1. Wire size should be determined in accordance with National Electrical Codes[...]
-
Page 3
P roduct Specifications 3 Specifications subject to change without notice. SEER – Seasonal Energy Efficiency Ratio COP – Coefficient of Performance TDR – T ime – Delay Relay HSPF – Heating Seasonal Performance Factor EER – Energy Efficiency Ratio NOTES: 1. T ested combination per ARI 210/240 standard. Fedders air handlers contain the TD[...]
-
Page 4
Split S ystem H eat P ump 4 Specifications subject to change without notice. LINE SET LENGTH AND SIZE BTUH SUCTION LINE SIZES LIQUID LINE SIZES 15 ft. 25 ft. 50 ft. 75 ft. 15 ft. 25 ft. 50 ft. 75 ft. 18 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 24 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 30 3/4 7/8 7/8 7/8 3/8 3/8 3/8 3/8 36 3/4 7/8 7/8 7/8 3/8 3/8 3/8 3/8 42 7/8 7/8[...]
-
Page 5
Split S ystem H eat P ump 5 Specifications subject to change without notice. AIR IN AIR IN (FRONT) AIR DISCHARGE AIR IN C B F AIR DISCHARGE FIELD POWER SUPPL Y CONNECTION 1 1/8" HOLE FIELD CONTROL SUPPL Y CONNECTION 1/4" HOLE LIQUID LINE CONNECTION D V APOR LINE CONNECTION E A DIMENSIONS DIMENSIONS IN INCHES MODELS ALL DIMENSIONS MINIMUM [...]
-
Page 6
Fedders Corporation 505 Martinsville Rd. Liberty Corner , NJ 07938 USA (908) 604-8686 Form No. F - CH13 All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a reg[...]