Field Controls S2000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Field Controls S2000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Field Controls S2000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Field Controls S2000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Field Controls S2000 should contain:
- informations concerning technical data of Field Controls S2000
- name of the manufacturer and a year of construction of the Field Controls S2000 item
- rules of operation, control and maintenance of the Field Controls S2000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Field Controls S2000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Field Controls S2000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Field Controls service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Field Controls S2000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Field Controls S2000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MODELS S2000 AND S2020 FOR GAS OR OIL FORCED AIR FURNACES, HEA T PUMPS AND ELECTRIC FURNACES has been designed to be simple to Install, Operate and Maintain. Read this manual before you install the Humidifier . Parts included in the Steam Humidifier package ar e: 1. Self Piercing Saddle V alve 2. Installation Instructions and Owners Manual 3. Mount[...]

  • Page 2

    SIMPLIFIED INST ALLA TION INSTRUCTIONS DET AILED INST ALLA TION INSTRUCTIONS 1. Insulate the water reservoir . See figure 3. 2. Select the mounting location on the duct and tape on the mounting template. 3. Drill the (8) 1/8" mountings holes. 4. Cut out the humidifier opening in the duct. 5. Insert the humidifier into the opening and screw in [...]

  • Page 3

    6. W A TER SUPPL Y - Required Criteria 9. WIRING THE STEAM HUMIDIFIER 7. M O U N T I N G T H E S T E A M H U M I D I F I E R 8. STEAM OPERA TION - Required Criteria A. W A TER SUPPL Y USING THE SADDLE V AL VE FURNISHED WITH UNIT . Important! See page 14. A. INST ALLING AND WIRING THE HUMIDIST A T B. OVERFLOW & DRAIN LINES - Required Criteria In[...]

  • Page 4

    Typi ca l Furnace S2000 & S2020 Humidifier Low V oltage T erminal Block G1 R G2 H H Heat only Thermostat W R G W R Heat Only System and Steam Humidifier with standard dry contact Humidistat Dry Contact Humidistat A A FIG. 6 Factory Jumper will stay in place unless a field installed Air Proving Device is used. FIG. 8 Bryant Evolution Furnace SPS[...]

  • Page 5

    8 . 0 0 ” 6 . 00 ” 7.50” 8 . 2 5 ” 1 0 . 5 0 ” 1 1 . 6 0 ” the room needed to install the unit in a certain location. The data can also be used to determine the minimum duct size the Steam Humidifier can be inserted into. The Steam Humidifier should not obstruct more than 25% of the cross sectional area of the selected duct. For Example[...]

  • Page 6

    F o r R e p l a c e m e n t P a r t s C a l l ( 8 0 0 ) 4 4 6 - 3 1 1 0 0 9 0 2 1 A 0 1 1 8 U . S . P A T E N T N U M B E R 5 7 5 8 0 1 8 s e r i a l n u m b e r E w c 3 8 5 H i g h w a y 3 3 , E n g l i s h t o w n , N J 0 7 7 2 6 C O N T R O L S , I N C . U L ® C U S L I S T E D 1 4 1 V P O W E R D R A I N F I L L H E A T E R B L O W E R T h e r[...]

  • Page 7

    It is recommended that humidistat settings of 30-45% not be exceeded. If condensation is noticed on windows during very cold outside temperatures, the humidistat setting should be lowered. RELA TIVE HUMIDITY CHAR T The maximum recommended relative humidity for your home depends upon many factors such as outdoor air temperature, type and placement o[...]

  • Page 8

    INITIAL ST AR T -UP * SEQUENCE OF OPERA TION * SER VICE “LED” INDICA TORS 1 1. ST AR T -UP & OPERA TING SEQUENCE Once the Steam Humidifier has been installed and the w a t e r, d r a i n , h u m i d i s t a t a n d b l o w e r i n t e r l o c k connections completed, the humidifier may be started. A. Disconnect the water line. Turn on the w[...]

  • Page 9

    14. SERVICE INDICA T ORS Seven LED lamps provided on the front panel indicate the functional status of the humidifier as shown in Figure 7 below . 9 A. L. M. N. O. B. C. D. E. F . G. H. I. J. K. Unplug the power cord from the 120 volt source for S2000 (240 volt for S2020) and allow the water to cool for at least 30 minutes prior to removal. T urn o[...]

  • Page 10

    10 A. G. B. C. D. E. F . The green "Power" light does not blink off and on. 1. The S2000 is not connected to an active 120 V AC 15 Amp power source. (S2020, 240 V AC, 10 AMP). 2. Call the T echnical Support Hotline. The "HEA TER" LED does not illuminate. 1. The humidistat is not closed, calling for humidity or the humidistat is [...]

  • Page 11

    SERVICE AND REPLACEMENT P ARTS 11 ITEM 1 120 VOL T HEA TER A SSEMBL Y 240 VOL T HEA TER A SSEMBL Y 24 VOL T SOLENOID V AL VE A SSEMBL Y W A TER LEVEL PROBE A SSEMBL Y THERMISTOR PROBE A SSEMBL Y CIRCUIT BOARD A SSEMBL Y DRAIN V AL VE ASSEMBL Y T ANK BAFFLE W A TER HAMMER ARRESTER (not shown) ANODE INSULA TION KIT (not shown) 2002 2003 2007 2008 WH [...]

  • Page 12

    Figure 18 12 DRAIN COCK V AL VE "T" ADAPTER, 1/4" NPT OVERFLOW TUBE, .50 ID x 6" LG. BARBED TEE, 1/4-18 NPT TO ½ " JUMPER WIRE, 20GA. X 1.50" LONG MOLEX PLUG BLACK WIRES 18GA. X 18" LONG SOLENOID V AL VE, 24/60 V AC 2 63 0 A irp o rt Ro a d K in s t on , N C 28 5 04 P H : 2 52 . 52 2 . 30 31 FA X : 25 2 . 52 2.02[...]

  • Page 13

    Smart Digital Humidistat Installation and Owner's Manual The 072000 is a digital humidifier control that can automatically adjust the indoor humidity set point as the outside air t em p e r a tu r e c h an g e s . T h is i n t e ll i g e n t control will maintain accurate humidity levels and a more comfortable indoor environment. The actual in[...]

  • Page 14

    Z100 A SSEMBL Y INST ALL A TION INSTRUCTIONS & OWNER'S MANUAL Z100 REPL ACEMENT INSTRUCTIONS ELECTRONIC STEAM POWER HUMIDIFIERS MODEL # S2000 AND S2020 APPLICA TION NOTE AN 131 C o p yr igh t © 2 0 1 1 Fi e ld Co n trols A l l Ri g h t s Rese rved . S U P P L E ME N T T O T H E T h e F i el d Co n trol s St e a m H u mi d i fie r no w co[...]

  • Page 15

    APPLICA TION NOTE P ART # 2009 AN 151 SC100 - P AR T # 2009 DECORA TIVE COVER S2000/S2020 STEAM HUMIDIFIER SC100 Installation Instructions P/ N 09 0 3 76 A0 15 1 R EV. A Co p yrig h t 2 01 1 © F ie l d Co n t rol s I n c. , Al l Ri g hts Re se rve d S U P P LEM E NT TO TH E ELECTR ON IC S TE A M P OWE R HU M ID IFI E RS M ODEL # S 2 0 0 0 A N D S [...]

  • Page 16

    16 Model Number:____________________Serial Number:____________________Date Code:_____________________ Date Purchased:_________________________________________________________________________________ Date Installed: __________________________________________________________________________________ Date Inspected:_____________________________________[...]