Field Controls UV-18X manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Field Controls UV-18X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Field Controls UV-18X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Field Controls UV-18X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Field Controls UV-18X should contain:
- informations concerning technical data of Field Controls UV-18X
- name of the manufacturer and a year of construction of the Field Controls UV-18X item
- rules of operation, control and maintenance of the Field Controls UV-18X item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Field Controls UV-18X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Field Controls UV-18X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Field Controls service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Field Controls UV-18X.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Field Controls UV-18X item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    UV-AIRE™ AIR PURIFYING SYSTEM Mode l: UV-18X READ THESE INSTRUCTIONS CAREFULLY AND COMPLETE LY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE. SAFETY CON[...]

  • Page 2

    Page 2 I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or co ndition nor for use in the mitigation, treatment, or pr evention of any disease or condition. II. GENERAL INFORMATION There are different size units avail able, depending on t he squ are footage of your home. See ch[...]

  • Page 3

    Page 3 2. Determine the type of duct you have. (For flex duct applications, refer to Figure 21 on page 8) I F YOU HAVE METAL DUCT : a. Apply supplied wet and stick mounting template to air d uct in either a vertical or horizontal position as shown in Figure 2. b. Drill 1/8” diameter mounting hole s at positions indicated on template. c. Cut out r[...]

  • Page 4

    Page 4 3. Remove base unit and cover from box. 4. Apply supplied “Duct Se al Kit” according to instructions included in kit. (See Figure 12) 5. Determine whether to use flat or angled bracket. (Refer to UV-Aire Configurations in Section III for aid in this de cisi on) a. Flat Bracket Installation i. Remove the two hex nuts and flat bracket from[...]

  • Page 5

    Page 5 Figure 20 8. Insert lamp through hole until lamp cann ot be inse rted any further. (See Figure 16) 9. Swing swivel bracket over end of lamp. Ha n d-tighten the wing nut on stud. (See Figure 17) Be careful not to ove r tighten the wing nut. The porcelain at the lamp b ase may crack when ov er tightened. 10. Plug ballast plug into end of lamp.[...]

  • Page 6

    Page 6 Diagram A Patent Pending 45° Installation Double La mp (Angled Br acket) Angle option allows longer lamps to fit in smaller ducts. (16” Duct) IV. BULB MOUNTING BRACK ET SELECTION AND INSTALLATION The UV-AIRE TM units come with an a ngled mounting bracket and flat mount ing bracket to position the bul b either straight or at an angle. Cho [...]

  • Page 7

    Page 7 V. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire™ Ai r Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously fo r maximum lamp life and light effectiveness. VI. REPLACEMEN T PROCEDURE VERY IMPORTANT: Turn switch on unit to ‘OFF’ po[...]

  • Page 8

    Page 8 IX. FLEX DUCT INSTALLATION For installations on duct system s with a metallic main duct an d flex duct branches , follow the instructions i n figure 21 below. The health aspects associa ted with the use of these products and t heir ability to aid in di sinfecting of environmental air have not been investigated b y UL. P/N 46453300 Rev C 04/0[...]