Go to page of
Similar user manuals
-
Indoor Fireplace
FireplaceXtrordinair 95400413
6 pages 0.59 mb -
Indoor Fireplace
FireplaceXtrordinair 98500507
4 pages 0.31 mb -
Indoor Fireplace
FireplaceXtrordinair 4915E
8 pages 1.07 mb -
Indoor Fireplace
FireplaceXtrordinair 1080
4 pages 0.26 mb -
Indoor Fireplace
FireplaceXtrordinair 95800624
4 pages 0.35 mb -
Indoor Fireplace
FireplaceXtrordinair 44 DV XXL EF
56 pages 2.03 mb -
Indoor Fireplace
FireplaceXtrordinair 864 See-Thru
8 pages 1.06 mb -
Indoor Fireplace
FireplaceXtrordinair 95400411
6 pages 0.59 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of FireplaceXtrordinair 44 DV XXL EF, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FireplaceXtrordinair 44 DV XXL EF one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of FireplaceXtrordinair 44 DV XXL EF. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of FireplaceXtrordinair 44 DV XXL EF should contain:
- informations concerning technical data of FireplaceXtrordinair 44 DV XXL EF
- name of the manufacturer and a year of construction of the FireplaceXtrordinair 44 DV XXL EF item
- rules of operation, control and maintenance of the FireplaceXtrordinair 44 DV XXL EF item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FireplaceXtrordinair 44 DV XXL EF alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FireplaceXtrordinair 44 DV XXL EF, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FireplaceXtrordinair service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FireplaceXtrordinair 44 DV XXL EF.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the FireplaceXtrordinair 44 DV XXL EF item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
TM Tested and Listed by OMNI-Test Laboratories, Inc. Beaverton, Oregon Report # ANSI Z21.88 • Built-In Direct Vent Fireplace • Natural Gas or Propane • Residential or Mobile Home WARNING : If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.[...]
-
Page 2
2 Introduction Travis Industries 4050114 100-01149 Introduction We welcome you as a new owner of a Fireplace Xtrordinair gas fireplace. In purchasing a Fireplace Xtrordinair you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Fireplace Xtrordi[...]
-
Page 3
Safety Precautions 3 Travis Industries 4050114 100-01149 Introduction Introduction & Important Information ................2 Safety Precautions Safety Precautions ......................................4 Features & Specifications Features ....................................................6 Installation Options .............................[...]
-
Page 4
4 Safety Precautions Travis Industries 4050114 100-01149 4 • IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department • This unit must be instal[...]
-
Page 5
Safety Precautions 5 Travis Industries 4050114 100-01149 • Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it. • Light the heater using the built-in piezo igniter. Do not use matche[...]
-
Page 6
6 Features and Specifications Travis Industries 4050114 100-01149 6 Features: - Works During Power Outages (millivolt system) - High Efficiency - Optional Thermostat or Remote Control - Realistic "Wood Fire" Look - Two Quiet Blowers for Effective Heat Distribution - Convenient Operating Controls - Variable-Rate Heat Output - Low Maintenan[...]
-
Page 7
Installation (for qualified installers only) 7 Travis Industries 4050114 100-01149 Installation Warnings: ! Failure to follow all of the requirements may result in property damage, bodily injury, or even death. ! This heater must be installed by a qualified installer who has gone through a training program for the installation of direct vent gas ap[...]
-
Page 8
8 Installation (for qualified installers only) Travis Industries 4050114 100-01149 8 Installation Overview Non-combustible facing (see the section "Facing Requirements") See the section "Acceptable Vent Lengths" See the section "Horizontal Termination Requirements" See the section "Gas Line Installation" See [...]
-
Page 9
Installation (for qualified installers only) 9 Travis Industries 4050114 100-01149 Fireplace Placement Requirements Minimum Framing Dimensions A 1" clearance is required along the sides and back of the fireplace. The 1" stand-offs on the sides and 10- 1/2" stand-offs on the top of the fireplace are designed to separate the fireplace [...]
-
Page 10
10 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Clearances • When installed, walls in front of the fireplace must be a minimum 3-1/2" to the side of the faceplate. • Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies. • Fireplace must be place[...]
-
Page 11
Installation (for qualified installers only) 11 Travis Industries 4050114 100-01149 Corner Installations A typical 45 ° installation uses the minimum framing dimensions shown in the illustration below (NOTE: all clearances still apply). Approx. 16" 23-1/8" 1" Standoffs 19-5/8" 19-1/2" Min. 1" Clearance 60-3/8" Ra[...]
-
Page 12
12 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Gas Line Requirements ! The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below. ! The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure [...]
-
Page 13
Installation (for qualified installers only) 13 Travis Industries 4050114 100-01149 Electrical Connection ! Make sure the household breaker is shut off prior to working on any electrical lines. ! The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrica[...]
-
Page 14
14 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Vent Requirements ! The vent must maintain the required clearance to combustible materials to prevent a fire (see “ Clearances ” below). Do not fill air spaces with insulation. ! The gas appliance and vent system must be vented directly to the outside of the bui[...]
-
Page 15
Installation (for qualified installers only) 15 Travis Industries 4050114 100-01149 Vent Installation • In addition to the requirements below, follow the requirements provided with the vent. Vertical Termination (part # 1291) Use a roof flashing and storm collar whenever passing through the roof Vertical Vent Requirements Horizontal Vent Requirem[...]
-
Page 16
16 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Approved Vent Configurations Restrictor Position • A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures proper combustion for all vent configurations. Depending upon the vent configuration, you may be required to adj[...]
-
Page 17
Installation (for qualified installers only) 17 Travis Industries 4050114 100-01149 Vertical Terminations with 0, 2, or 4 45° Offsets Offset Length Hor. Offset Ve r t . R is e None 5" 1 ' 1' Section 1' 1' 7" 2' Section 1' 9 " 2' 4 " 3' Section 2' 5" 3' 4' Section 3&apo[...]
-
Page 18
18 Installation (for qualified installers only) Travis Industries 4050114 100-01149 18 Horizontal Terminations with One Vertical Elbow The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position. NOTE : If you are installing this fireplace with a minimum of vent rise, and are experiencing intermittent [...]
-
Page 19
Installation (for qualified installers only) 19 Travis Industries 4050114 100-01149 Horizontal Terminations with Three Vertical Elbows The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position. NOTE: • A total of three elbows must be used. • No horizontal elbows may be used (a horizontal elbow is[...]
-
Page 20
20 Installation (for qualified installers only) Travis Industries 4050114 100-01149 V e r t ica l T e r m in a tio n s with T wo V e r t ica l 9 0 ° E lb o ws The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position. 5 feet 10 feet (min.) 15 feet 20 feet 25 feet 30 feet 0 feet 40' (max) 5 feet[...]
-
Page 21
Installation (for qualified installers only) 21 Travis Industries 4050114 100-01149 Termination Requirements (see the illustration below) ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" clearance from any door or window B Minimum 12" above any grade, veranda, porch, deck or balcony C Minimum 12" from out[...]
-
Page 22
22 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Hearth Requirements 6-1/4" Do not build the hearth above this ledge. 12 ” Min. 53" Min. Cement Board (required) Tile, Marble, Brick, or other Non-Combustible Decorative Trim (may be combustible) Min. 3/4 ” Max. 15/16 ” Floor Mounted Fireplaces Raised[...]
-
Page 23
Installation (for qualified installers only) 23 Travis Industries 4050114 100-01149 Facing Requirements NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. Adhesive WARNING : Do not use adhesive to secure[...]
-
Page 24
24 Installation (for qualified installers only) Travis Industries 4050114 100-01149 24 Face Dimensions 33-7/8" 6-3/8" 46” Access Door Radius = 45-3/8” Classic Arched (Gold, Black, or Artisan*) * Artisan faces may vary slightly in size due to the forging process. 34-1/4” 43-3/4” Access Door Architectural Faces (French Country, Arts[...]
-
Page 25
Installation (for qualified installers only) 25 Travis Industries 4050114 100-01149 Fireplace Facing Detail 6-1/4" 3-7/8" 42-3/4 ” 31-3/8" 7-5/8" 27-5/8" 27-1/2" 1" 1" Access Door 1" Face 1" 1/4" Arch Faces Glass 1/2" Air Space The overlap is 1-1/2" along the top of the face. NOTE: [...]
-
Page 26
26 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Facing Example - Facing Under 1” Thick • To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing directly next to the fireplace. See the illustration below. Fireplace 1" 1/2" Drywall 1/2" Concrete Board [...]
-
Page 27
Installation (for qualified installers only) 27 Travis Industries 4050114 100-01149 Facing Example – Facing Over 1” Thick Arched Faces : For facing material over 1" thick (e.g. brick, river rock), install the facing around the perimeter of the set-up face shipped with the fireplace. See the illustration below. Rectangular Faces : For facin[...]
-
Page 28
28 Installation (for qualified installers only) Travis Industries 4050114 100-01149 Mantel Requirements • The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. Combustible or Non-Combustible Mantels Max. Mantel[...]
-
Page 29
Finalizing the Installation (for qualified installers only) 29 Travis Industries 4050114 100-01149 1 Remove the glass (and arch covers) following the directions below. Warning: The appliance must be completely cool before removing the glass. Warning: To prevent damage, do not abuse, strike, or slam the glass shut. Note : Attach the arch covers afte[...]
-
Page 30
30 Finalizing the Installation (for qualified installers only) Travis Industries 4050114 100-01149 Glass Frame Removal and Installation (continued) The spring pin can come loose from the latch assembly. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the spring pin if it becomes loose. To re-i[...]
-
Page 31
Finalizing the Installation (for qualified installers only) 31 Travis Industries 4050114 100-01149 ? If converting this unit to propane, do so now (see the instructions on page 47). 2 Install the rock wool, log set, kibbles, and embers (if using the decorative fireback, install it prior to the log set). Warning: Failure to position the parts in acc[...]
-
Page 32
32 Finalizing the Installation (for qualified installers only) Travis Industries 4050114 100-01149 (b) Place the Middle Logs Line up the hole in the left middle log with this pin. After placing the logs, push them backwards to the outside edges contact the rear log Line up the two holes in the right middle log with these bolts (or pins)[...]
-
Page 33
Finalizing the Installation (for qualified installers only) 33 Travis Industries 4050114 100-01149 (c) Placing the Front Log Line up the hole in the front log with this bolt (or pin) The front log rests on the right middle log.[...]
-
Page 34
34 Finalizing the Installation (for qualified installers only) Travis Industries 4050114 100-01149 (d) Placing the Twigs Line up the hole in the left twig with this pin. Line up the two holes in the right twig with these pins When in position the twigs should look like this.[...]
-
Page 35
Finalizing the Installation (for qualified installers only) 35 Travis Industries 4050114 100-01149 ! We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up. 3 Replace the glass (and arch covers when using arched faces - see page 29). 4 Turn[...]
-
Page 36
36 Finalizing the Installation (for qualified installers only) Travis Industries 4050114 100-01149 configuration is correct, yet the flames are lifting or ghosting, shut off gas to the fireplace and contact the dealer for information on remedying the problem. ! This fireplace has been tested at altitudes up to 8,000 feet. In this testing we have fo[...]
-
Page 37
Operation 37 Travis Industries 4050114 100-01149 Before You Begin Warning: Read this entire manual before you use your new fireplace (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death. Warning: Do not operate appliance with the gl[...]
-
Page 38
38 Operation Travis Industries 4050114 100-01149 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF". However, the pilot will go out if the gas is shut off, the propane tank runs out (o[...]
-
Page 39
Operation 39 Travis Industries 4050114 100-01149 Starting the Fireplace for the First Time + Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to vent t[...]
-
Page 40
40 Operation Travis Industries 4050114 100-01149 Adjusting the Blower Speed The internal blower helps transfer the heat from the fireplace into the room. It will not turn on until the fireplace is up to temperature (approximately 10 minutes after starting). See the illustration below for instructions on adjusting the blower speed. BLOWER CONTROL LO[...]
-
Page 41
Maintenance (for qualified service personnel only) 41 Travis Industries 4050114 100-01149 Maintaining Your Fireplace's Appearance ! Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean prior to turning the heater on. Clean plated surfaces with denatured alcohol and a soft cloth [...]
-
Page 42
42 Maintenance (for qualified service personnel only) Travis Industries 4050114 100-01149 Troubleshooting Table Problem: Possible Cause: Don't Call for Service Until You: Pilot Will Not Light A gas shut off valve is turned off The gas control knob isn't turned to "PILOT" The valve control knob isn't pushed in The igniter wa[...]
-
Page 43
Maintenance (for qualified service personnel only) 43 Travis Industries 4050114 100-01149 How this Fireplace Works ! This fireplace was designed with safety as the primary concern. Many of the components inside this fireplace are for safety purposes. Therefore, only certified gas service technicians should service this fireplace. What Turns the Mai[...]
-
Page 44
44 Maintenance (for qualified service personnel only) Travis Industries 4050114 100-01149 Wiring Diagram Caution : Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Fireplace Blower Rheostat Junction Box Hot (black) Common (white) Ground (green) Blower Snap Disk Optional Power [...]
-
Page 45
Safety Label 45 Travis Industries 4050114 100-01149 The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is shown below. Fireplace Xtrordinair 44DVXXL V ented Gas Fireplace Heater T ested to: ANSI Z21.88-2002 “V ented Gas Fireplace Heater” and UL 307b-1995 “Gas Burning Heating Appliances for Ma[...]
-
Page 46
46 Limited 7 Year Warranty Travis Industries 4050114 100-01149 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas applianc[...]
-
Page 47
Optional Equipment (for qualified installers only) 47 Travis Industries 4050114 100-01149 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Remove the glass (see page 29). Remove the logs (if installed - page 31) 2 Remove the burner (see illustration to the right). a c Lift the pilot [...]
-
Page 48
48 Optional Equipment (for qualified installers only) Travis Industries 4050114 100-01149 3 Follow the directions below to replace the orifices. 1/2" Wrench Use a 1/2 ” open end wrench to unscrew all three orifices. Screw the LP orifice in so the orifice shoulder protrudes 5/16 ” (indicating full insertion). d Look here for the orifice ide[...]
-
Page 49
Optional Equipment (for qualified installers only) 49 Travis Industries 4050114 100-01149 4 Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice Lift the pilot hood off the pilot assembly. 5/32" Hex Use a hex wrench to unscrew the orifice. Remove the orifice and replace with the LP orifice. Screw th[...]
-
Page 50
50 Optional Equipment (for qualified installers only) Travis Industries 4050114 100-01149 POWER HEAT DUCT (part # 98500769) The optional heat duct allows the fireplace to transfer heat to separate locations in the home. One or two ducts may be used . Installation should take place prior to installing drywall. Warning : This kit must be installed as[...]
-
Page 51
Optional Equipment (for qualified installers only) 51 Travis Industries 4050114 100-01149 2 Attach the blower box to the framing or floorboards of the home following the instructions below. Wall or Ceiling Mounting b Attach the wall mounting brackets to the blower box. Mount the bracket to these holes for 2 x 4 walls Mount the bracket to these hole[...]
-
Page 52
52 Optional Equipment (for qualified installers only) Travis Industries 4050114 100-01149 3 Attach the starter ring to the fireplace following the directions below (use the most convenient side). Bend the tabs on the bottom of the starter ring up to lock it in place. 1/4" Nutdriver Remove and discard the cover plate. Starter Ring 4 Install the[...]
-
Page 53
Optional Equipment (for qualified installers only) 53 Travis Industries 4050114 100-01149 5 Attach the grill (and wall adapter, if necessary). Grill Wall Adapter (for use when the blower box protrudes from the wall - primarily on 2 x 4 walls) Phillips Screwdriver Screws (included with this kit) WIRING DIAGRAM Warning : All wiring should be done by [...]
-
Page 54
54 Optional Equipment (for qualified installers only) Travis Industries 4050114 100-01149 6 Follow the directions below to wire the blower box. Remove the cover from the blower box. a b Insert sheathed cable through the cable clamp. After the wires have been connected tighten the clamp to secure the cable. Secure the ground wire to the ground stud [...]
-
Page 55
Optional Equipment (for qualified installers only) 55 Travis Industries 4050114 100-01149 8 Run the free wire from the rheostat junction box to the fireplace. Follow the directions below to connect the heat duct circuit to the fireplace. a b Insert the sheathed cable from the rheostat through a cable clamp and push the cable clamp into the knock-ou[...]
-
Page 56
56 Index Travis Industries 4050114 100-01149 Approved Vent Configurations ..........................1 6 Adjusting the Blower Speed ..............................4 0 Adjusting the Flame Height ...............................3 9 Air Shutter Adjustment ......................................3 5 Altitude Considerations ..................................[...]