Go to page of
Similar user manuals
-
Home Security System
First Alert 2079F
8 pages 4.59 mb -
Home Security System
First Alert 3040DEF
8 pages 0.41 mb -
Home Security System
First Alert HS-4705-400
29 pages 5.16 mb -
Home Security System
First Alert FA148CP
56 pages 0.57 mb -
Home Security System
First Alert DWB-700
12 pages 0.34 mb -
Home Security System
First Alert 3035DEF
8 pages 0.41 mb -
Home Security System
First Alert DWS-471
32 pages 3.06 mb -
Home Security System
First Alert FA142C
44 pages 0.22 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of First Alert FA120C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of First Alert FA120C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of First Alert FA120C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of First Alert FA120C should contain:
- informations concerning technical data of First Alert FA120C
- name of the manufacturer and a year of construction of the First Alert FA120C item
- rules of operation, control and maintenance of the First Alert FA120C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of First Alert FA120C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of First Alert FA120C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the First Alert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of First Alert FA120C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the First Alert FA120C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
USER'S MANUAL FA120C Security System N5100-3V3 9/96 Previous Menu[...]
-
Page 2
Ð2Ð TABLE OF CONTENTS SYSTEM OVERVIEW ............................................................................................................................... ... 4 Keypads ............................................................................................................................... .................... 4 Zones ...........[...]
-
Page 3
Ð3Ð ( continued) TABLE OF CONTENTS DISARMING THE SYSTEM AND SILENCING ALARMS (Using the 1 OFF Key)............................................. 20 USING THE KEYSWITCH ........................................................................................................................... 21 CHIME MODE (Using the 9 CHIME Key) ...................[...]
-
Page 4
Ð4Ð SYSTEM OVERVIEW General Congratulations on your ownership of a First Alert Professional Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, including microcomputer technology to monitor all system status. Basically, this system offers you three forms of protec[...]
-
Page 5
Ð5Ð (continued) SYSTEM OVERVIEW Alarms When an alarm occurs, both the keypad and external sounders will sound, and a message at the keypad will identify the zone(s) causing the alarm. In addition, if your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, you simply disarm the system. F[...]
-
Page 6
Ð6Ð ABOUT THE KEYPADS Keypad Types All commands and procedures described herein are illustrated for Fixed- Word Display keypads, however, an Alpha Display keypad (with a 2-line LCD display for more detailed protection point identification and system status, but with similar commands and procedures) is available and might have been used instead. K[...]
-
Page 7
Ð7Ð SUMMARY OF SYSTEM STATUS DISPLAYS AWAY All burglary zones, interior & perimeter, are armed. STAY Perimeter burglary zones, such as windows and doors are armed. INSTANT Perimeter burglary zones armed and entry delay is turned off. BYPASS One or more burglary protection zones have been bypassed. NOT READY Appears when burglary portion of th[...]
-
Page 8
Ð8Ð SUMMARY OF KEYPAD FUNCTIONS 1. DISPLAY WINDOW: Displays protection zone ID and system status messages. 2. 1 OFF KEY : Disarms burglary portion of the sys- tem, silences alarms and audible trouble indicators, and clears visual display after problem's correction. 3. 2 AWAY KEY : Arms the entire burglary system , perimeter and interior. 4. [...]
-
Page 9
Ð9Ð 15. ARMED INDICATOR: (RED). Lit when the system has been armed (STAY, AWAY INSTANT or MAXIMUM). 16. INTERNAL SOUNDER: The built-in keypad sounder mimics the alarm sounder during alarms, and will also "beep" during certain system functions. (see SUMMARY OF AUDIBLE/ VISUAL NOTIFICATION ). 17. EMERGENCY KEYS: Individual keys A , B , an[...]
-
Page 10
Ð10Ð SECURITY CODES General At the time of installation, your installer programmed a personal four-digit Master code, known only to you and yours. This code is used to perform most system functions, including arming and disarming of the system. As an additional safety feature, temporary user codes can be assigned (see next page) for use by those [...]
-
Page 11
Ð11Ð SECURITY CODES To Assign, Change, or Delete User Codes 4-DIGIT USER CODES It is recommended that obvious codes such as 1111 o r 1234 not be assigned. Important: Temporary users should not be shown how to use any system function they do not need to know (e.g., bypassing protection zones). 1. Enter your Master code and press the CODE key. 2 . [...]
-
Page 12
Ð12Ð ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the main door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the main door. The system must be disarmed, ho[...]
-
Page 13
Ð13Ð CHECKING FOR OPEN ZONES Using the ÊÊ ✴ ÊÊ READY Key Before your system can be armed, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the keypad will display a "Not Ready" message, and if your keypad has a READY indicator light, it will not [...]
-
Page 14
Ð14Ð BYPASSING PROTECTION ZONES Using the ÊÊ 6 ÊÊ BYPASS Key LIMITATION The system will not allow fire zones to be bypassed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first.[...]
-
Page 15
Ð15Ð BYPASSING PROTECTION ZONES Quick Bypass Ask your installer if "Quick Bypass" is active for your system, and if so, check here: Ê Ê Ê If your system supports "Quick Bypass", it allows you to automatically bypass all open (faulted) zones without having to enter zone numbers in- dividually. To use this feature, enter your[...]
-
Page 16
Ð16Ð ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the ÊÊ 3 ÊÊ STAY Key BEFORE ARMING close all doors and windows (see CHECKING FOR OPEN ZONES on page 13). Use this key when you are staying inside, but expect someone to use an entry/exit door later. 1. Enter your security code and press the STAY key. 2. The keypad beeps three times and disp[...]
-
Page 17
Ð17Ð ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Using the Ê Ê7 ÊÊ INSTANT Key BEFORE ARMING close all doors and windows (see CHECKING FOR OPEN ZONES on page 13). Use this key when you are staying inside and do not expect anyone to use an entry/exit door. 1. Enter your security code and press the INSTANT key. 2. The keypad beeps three times an[...]
-
Page 18
Ð18Ð ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the Ê Ê2 ÊÊ AWAY Key BEFORE ARMING close all doors and windows (see CHECKING FOR OPEN ZONES on page 13). Use this key when no one will be staying inside. 1. Enter your security code and press the AWAY key. 2 . The keypad beeps twice and displays the armed message. The red ARMED indicator li[...]
-
Page 19
Ð19Ð ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the ÊÊ 4 ÊÊ MAXIMUM Key BEFORE ARMING close all doors and windows (see CHECKING FOR OPEN ZONES on page 13). Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when retiring for the night and no one will be moving through protected interio[...]
-
Page 20
Ð20Ð DISARMING THE SYSTEM AND SILENCING ALARMS Using the ÊÊ 1 ÊÊ OFF Key IMPORTANT: I f you return and the main burglary sounder is on: DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. I f you return after an alarm has occurred and the main sounder has shut itself off: the keypad will beep rapidly upon your entering, indicati[...]
-
Page 21
Ð21Ð USING THE KEYSWITCH General Y our system may be equipped with a keyswitch for use when arming and disarming. A single red light on the keyswitch plate indicates the status of your system as follows: OFF = Disarmed, Not Ready for Arming SLOW FLASHING = Disarmed, Ready for Arming RAPID FLASHING = Armed STAY or AWAY Arming To arm in the AWAY mo[...]
-
Page 22
Ð22Ð CHIME MODE Using the ÊÊ 9Ê Ê CHIME Key This feature can be used only while the burglary system is disarmed. Y our system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the keypad whenever a protected door or window is opened. Pressing the READ[...]
-
Page 23
Ð23Ð (continued) PANIC KEYS A B C D OFF A W A Y ST A Y MAXIMUM TEST BYP ASS INST ANT CODE CHIME READY 1 2 3 4 5 6 7 8 9 * 0 # { THESE KEYS NOT PRESENT ON ALL KEYP ADS } INDIVIDUAL P ANIC KEYS (“D” NOT USED) 1 3 ✱ ✱ # # & & & } P AIRED P ANIC KEYS CHECK IF PANIC P R O G R A M M E D ZONE ACTIVE KEY(S) F U N C T I O N NUMBER ÊÊ[...]
-
Page 24
Ð24Ð TESTING THE SYSTEM TO BE CONDUCTED WEEKLY Using the ÊÊ 5 ÊÊ TEST Key NO ALARM REPORTS WILL BE SENT TO THE CENTRAL MONITORING STATION while the system is in Test mode. The TEST key puts your system into Test mode, which allows each pro- tection point to be checked for proper operation. 1 . Disarm the system and close all protected windows[...]
-
Page 25
Ð25Ð (continued) TESTING THE SYSTEM 6 . Follow the manufacturer's instructions to test all smoke detectors, to ensure that all are functioning properly. The identification of each detector should appear on the display when each is activated. 7 . After all protection points have been checked and restored, there should be no zone identificatio[...]
-
Page 26
Ð26Ð TROUBLE CONDITIONS "Check" and "Battery" Displays Not all systems use wireless sensors. The word CHECK on the keypad's display, accompanied by a "beeping" at the keypad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK"[...]
-
Page 27
Ð 27 Ð (continued) TROUBLE CONDITIONS 3. A display of "BAT" with no zone number or beeping indicates that the main standby battery in your control is weak. If this condition persists for more than one day (with AC present), CALL FOR SERVICE. 4. A display of "BAT" with a zone number and a once per 40 seconds "beeping"[...]
-
Page 28
Ð 28 Ð (continued) TROUBLE CONDITIONS Other Displays dl : If this remains displayed for more than 1 minute, your system is disabled. CALL FOR SERVICE IMMEDIATELY. CC : The system is in communication with the central station for change of function or status verification. If this message persists for more than 10 minutes, CALL YOUR SERVICE COMPANY.[...]
-
Page 29
Ð29Ð FIRE ALARM SYSTEM IF INSTALLED General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will automatically send signals to your system, triggering a loud, interrupted sound from the keypad. An interrupted sound will also be [...]
-
Page 30
Ð30Ð (continued) FIRE ALARM SYSTEM IF INSTALLED Silencing Fire Alarms 1. Silence the alarm by pressing the OFF key (security code not needed to silence fire alarms). To clear the display, enter your code and press the OFF key again (Memory of Alarm). 2 . If the keypad does not indicate a READY condition after the second OFF sequence, press the RE[...]
-
Page 31
Ð31Ð NATIONAL FIRE PROTECTION ASSOCIATION RECOMMENDATIONS ON SMOKE DETECTORS General With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's Standard #74 noted below. DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING ROOM ✪ ✪ ✪ ✪ [...]
-
Page 32
Ð32Ð EMERGENCY EVACUATION Steps to Safety • FRONT • BACK • BEDROOM BA TH BEDROOM KITCHEN BACK DOOR 1 FLOOR ST BEDROOM BEDROOM 2 FLOOR ND BA TH BEDROOM PORCH CLOSET Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Plan on your detector [...]
-
Page 33
Ð33Ð QUICK GUIDE TO ALARM SYSTEM FUNCTIONS FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. To view faulted zones when system not ready. Arm System Enter code. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM) Arms system in mode selected. Quick Arm (if programmed) Press #. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM) A[...]
-
Page 34
Ð34Ð SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS SOUND CAUSE DISPLAY LOUD, INTERRUPTED Keypad & External FIRE ALARM FIRE and ALARM are displayed; protection zone in alarm is displayed. LOUD, CONTINUOUS Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; protection zone in alarm is also displayed. ONE SHORT BEEP (not repeate[...]
-
Page 35
Ð35Ð PROTECTION ZONES LIST One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system (although not every zone number can be used). For example, the sensing device on your Entry/Exit door may have been assigned to zone 06, sensing devices on windows in the maste[...]
-
Page 36
Ð36Ð Ð NOTES Ð[...]
-
Page 37
Ð37Ð OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit. A . GENERAL INFORMATION: Insured's Name and Address: _________________________________________________________________ _________________________________________________________[...]
-
Page 38
Ð38Ð OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E . SMOKE DETECTOR LOCATIONS: ÊÊ Furnace Room Ê Ê Kitchen Ê Ê Bedrooms Ê Ê Attic ÊÊ Basement Ê Ê Living Room Ê Ê Dining Room Ê Ê Hall F . BURGLARY DETECTING DEVICE LOCATIONS: ÊÊ Front Door Ê Ê Basement Door Ê Ê Rear Door Ê Ê All Exterior Doors ÊÊ 1st Floor Window[...]
-
Page 39
Ð39Ð CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equip- ment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to th[...]
-
Page 40
Ð40Ð UL NOTICE: This is a "Grade A" Residential System. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not ins[...]
-
Page 41
Ð41Ð (continued) FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary dis- continuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also[...]
-
Page 42
Ð42Ð WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: ¥ Intruders may ga[...]
-
Page 43
Ð43Ð (continued) WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM ¥ Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken o[...]
-
Page 44
N5100-3V3 9/96 ONE YEAR LIMITED WARRANTY Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its First Alert security equipment (the "product") to be free from defects in materials and workmanship for one year from date of original purchase, under norm[...]