First Alert MODEL FCD3N manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of First Alert MODEL FCD3N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of First Alert MODEL FCD3N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of First Alert MODEL FCD3N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of First Alert MODEL FCD3N should contain:
- informations concerning technical data of First Alert MODEL FCD3N
- name of the manufacturer and a year of construction of the First Alert MODEL FCD3N item
- rules of operation, control and maintenance of the First Alert MODEL FCD3N item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of First Alert MODEL FCD3N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of First Alert MODEL FCD3N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the First Alert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of First Alert MODEL FCD3N.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the First Alert MODEL FCD3N item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MODEL FCD3N—User’ s Manual Batter y-Operated Carbon Monoxide Alarm M06-1042-001 7/00 M06_1042_001.E Page -1 Wednesday, July 12, 2000 9:26 AM[...]

  • Page 2

    1 T ABLE OF CONTENTS CHAPTER 1: INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 How Y our CO Alarm W orks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    2 CHAPTER 1: Introduction BASIC SAFETY INFORMATION IMPORT ANT! Dangers, W arnings, and Cautions alert you to important operating instructions or to potentially hazar dous situations. Pay special attention to these items. IMPORT ANT! THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide fr om ANY source of combustion. It is [...]

  • Page 4

    3 HOW Y OUR CO ALARM WORKS General Information A CO Alarm measur es the CO levels in the air . It will alarm if CO levels rise quickly (if the heat exchanger on your furnace br eaks, for example), or if CO is consistently pr esent (a slow CO leak on a fuel-burning appliance). This carbon monoxide alarm featur es a permanently installed sensor , thr[...]

  • Page 5

    4 WHAT THE LIGHTS AND ALARM T ONES MEAN WELCOME CHIRP . Horn chirps and battery light blinks green once when battery is first connected. ALARM RECEIVING BA TTERY POWER BATTERY light flashes GREEN twice a minute. Horn is silent. LOW BA TTER Y WARNING. The BATTERY light turns YELLOW. It flashes and the horn “ chirps ” twice a minute. This warning[...]

  • Page 6

    5 CO ALARM SPECIFICATIONS Gas Detection at T ypical T emperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically . UL tested for false alarm r esistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). V alues[...]

  • Page 7

    6 CHAPTER 2: Installation WHERE TO INSTALL CO ALARMS The Consumer Pr oduct Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. For added pr otection, install additional CO Alarms in each separate bedroom, and on every level of your home. If your bedroom hallway is longer than 40 feet, [...]

  • Page 8

    7 WHERE NOT T O INSTALL Y OUR CO ALARM DO NOT locate this CO Alarm: • In garages, kitchens, furnace r ooms, or in any extr emely dusty , dirty or greasy ar eas. • Closer than 20 feet fr om a furnace or other fuel burning heat sour ce, or fuel burning appliances like a water heater . • Within 5 feet of any cooking appliance. • In extremely h[...]

  • Page 9

    8 HOW TO INSTALL Y OUR CO ALARM Read “ Where T o Install Y our CO Alarm ” before starting. This CO Alarm can be used on a tabletop or mounted on the wall. For tabletop use, choose a table no taller than 36 ” (92 cm); a fall from a high table could damage the Alarm ’ s sensitive components. Before you start installation, fi nd the pair of s[...]

  • Page 10

    9 For T abletop Use 1. Close the battery compartment by sliding the mounting bracket/battery door back onto the back of the CO Alarm. 2. T est the CO Alarm as described below . 3. Set the CO Alarm in plain view on a table where it will not be blocked by any obstructions.T able height should not exceed 36 ” (92 cm). IMPORT ANT! Put the CO Alarm wh[...]

  • Page 11

    10 CHAPTER 3: If Y our CO Alarm Sounds W ARNING! Actuation of your CO alarm indicates the presence of carbon monoxide (CO) which can kill you. In other wor ds, when your CO Alarm sounds, you must not ignor e it! If the Alarm Sounds: 1. Operate the T est/Silence button. 2. Call your emer gency services, fi re department or 911. W rite down the numb[...]

  • Page 12

    11 Using the Silence Feature W ARNING! NEVER remove the batteries fr om your CO Alarm to silence the horn. Use the silence featur e. Removing the batteries removes your pr otection! See pr evious page for details on r esponding to an alarm. The silence featur e is intended to temporarily silence your CO Alarm ’ s alarm horn while you correct the [...]

  • Page 13

    12 CHAPTER 4: T esting and Maintenance W EEKLY T ESTING W ARNING! DO NOT stand close to the alarm when the horn is sounding. Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding. Push and hold the T est/Silence button on the cover until you hear a “ chirp. ” The “ chirp ” marks the start [...]

  • Page 14

    13 REGULAR MAINTENANCE T o keep the CO Alarm in good working or der: • T est it every week using the T est/Silence button. • V acuum the CO Alarm cover once a month, using the soft brush attachment. Never use water , cleaners, or solvents, since these may damage the unit. T est the Alarm again after vacuuming. • Replace the battery when the C[...]

  • Page 15

    14 CHAPTER 5: What Y ou Need T o Know About CO What is CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not bur n completely , or are exposed to heat (usually fi re). Electrical appliances typically do not produce CO. These fuels include: W ood, coal, char coal, oil, natural gas, gasoline, ker osene, and propane. Commo[...]

  • Page 16

    15 Potential Sources Of CO In The Home Fuel-burning appliances like: portable heater , gas or wood burning fi replace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insuf fi cient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or fl ue, or cracked heat exchanger , blocked or clogged chimney opening.[...]

  • Page 17

    16 How Can I Protect My Family? A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm befor e carbon monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for pr oper maintenance of home appliances. T o help prevent CO problems and r educe the risk of CO poisoning: • C[...]

  • Page 18

    17 CHAPTER 6: Underwriters Laboratories Inc. UL2034 What Levels of CO Cause an Alarm? Underwriters Laboratories Inc. UL2034 de fi nes three speci fi c alarm points by which all residential CO Alarms must alarm. They ar e measured in parts per million (ppm) of CO over time (in minutes). UL2034 Requir ed Alarm Points: • If the alarm is exposed to[...]

  • Page 19

    18 CHAPTER 7: Troubleshooting Guide Problem... This means... You should... The BATTERY Light turns YELLOW. It flashes and the horn “ chirps ” twice a minute. Low battery warning. Install a new 9V alkaline or lithium battery*. During testing, when you press and hold the Test/ Silence button, the BATTERY Light turns YELLOW. Low battery Install a [...]

  • Page 20

    19 CHAPTER 8: General Limitations Of CO Alarms This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide alarms must be met. CO Alarms will not work without power . This alarm requires a 9V alkaline or lithium batte[...]

  • Page 21

    20 Limited W arranty Coverage: BRK Brands, Inc. warrants its enclosed carbon monoxide alarm to be free fr om defects in materials and workmanship under normal use for a period of fi ve years fr om the date of purchase. During the fi rst year after the date of purchase, BRK Brands, Inc. will r eplace any defective carbon monoxide alarm without cha[...]

  • Page 22

    21 NOTES M06_1042_001.E Page 21 Wednesday, July 12, 2000 9:26 AM[...]