Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fisher & Paykel HC230, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fisher & Paykel HC230 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fisher & Paykel HC230. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fisher & Paykel HC230 should contain:
- informations concerning technical data of Fisher & Paykel HC230
- name of the manufacturer and a year of construction of the Fisher & Paykel HC230 item
- rules of operation, control and maintenance of the Fisher & Paykel HC230 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fisher & Paykel HC230 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fisher & Paykel HC230, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fisher & Paykel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fisher & Paykel HC230.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fisher & Paykel HC230 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
HC230 SERIES Operating Manual Manuel de l’utilisation Manual del Usiario[...]
-
Page 2
SECTION English .................... A Francais ................... B Espa ñ ol ................... C[...]
-
Page 3
T ABLE OF C ONTENTS 1. Symbol Definitions ................................................................................2 2. W arnings .......................................................................................2 3. Oxygen Use W arnings .............................................................................2 4. Intended Use .....[...]
-
Page 4
2. W ARNINGS PLEASE NOTE:- This manual refers to the HC230 Series CP AP unit as "the device". 1. The device should only be used with masks, connectors and delivery tubes recommended by Fisher & Paykel Healthcare, or by your physician or r espiratory therapist. 2. Never operate the device if: a) it has a damaged power cord or plug, b) [...]
-
Page 5
A- 3 5. D ESCRIPTION OF THE DEVICE 5.1 Package Contents 5.2 Important Parts of Y our Device 1 x Spare Air Filter 1 x Power Cord Accessories 2 x W ater Chamber 1 x tube 1 x HC230 series POWER CORD 900HC221 TUBE 900HC010 CONNECTOR WA TER CHAMBER CHAMBER GUARD HEA TERPLATE WA TER LEVEL LINE FIL TER HOLDER DISPLA Y AIR FIL TER ON/OFF BUTTON 5.3 Accesso[...]
-
Page 6
A- 4 6. C LEANING & M AINTENANCE 1. Switch off the device and unplug fr om the power socket. 2. Wipe the exterior of the device with a clean, damp (not wet) cloth and mild dishwashing detergent. Do not use harsh abrasives or solvents, or these may damage the device. 3. DAIL Y Clean chamber and tube. • Remove the breathing tube fr om the chamb[...]
-
Page 7
A- 5 8. C ONTROLS AND D ISPLA Y Mode button Step through the options Down button Decrease Setting Up button Increase Setting Ramp button On/Off Button KEY FUNCTION & DESCRIPTION OPERA TION ON/OFF Switches the device ON & OFF RAMP Reduces pressure to a lower level to help you fall asleep. The pressure will gradually return to full operating [...]
-
Page 8
A- 6 8.2 P A TIENT M ENU S UMMARY Increase Decrease Press to activate Ramp Press once to switch device on/off Display MODE Humidity Setting (default) Pressure Setting Altitude Setting cmH 2 O 0,1,2,3,4 + - 0.5 INCREMENT 8.3 P A TIENT M ENU - A DDITIONAL S ETTINGS S UMMARY Increase Decrease Press to activate Ramp Press once to switch device on/off D[...]
-
Page 9
9. F REQUENTL Y A SKED Q UESTIONS When I wake up in the morning, my nose and throat feel dry . What can I do? T ry increasing your humidity setting. If this does not help, please contact your clinician for advice. How do I prevent condensation in the tubing? The humidity setting enables adjustment of humidity , so that there should be fine misting [...]
-
Page 10
11. O PERA TING C ONDITIONS : AMBIENT TEMPERA TURE: 5 ° - 35 ° C HUMIDITY : 10 - 95% RH AL TITUDE: 0 - 3000m (9000ft) Above 500m (1500 ft) the maximum operating pressur e will be reduced. 12. S TORAGE AND T RANSPORT CONDITIONS : The device should be stored and transported in envir onmental conditions of: -10 ° to 60 ° C . 13. T ROUBLESHOOTING :[...]
-
Page 11
B - 1 HC230 SERIES PPC A VEC SYST È ME D ’ HUMIDIFICA TION INT É GR É Les syst è mes de PPC de s é rie HC230 ont é t é con ç us pour le traitement à domicile du SAS. Pour une assistance compl é mentaire, veuillez contacter votre Bur eau local F&P – voir adr esse au verso. Conserver ce manuel pour futures r é f é rences. Fran ç [...]
-
Page 12
2. A VERTISSEMENT A noter: ce mode d'emploi se réfère à l'appareil de PPC HC230 comme l'appareil 1. L ’ appareil ne peut ê tre utilis é qu ’ avec des masques, connecteurs et circuit r ecommand é s par Fisher & Paykel Healthcare, votr e m é decin ou th é rapeute. 2. Ne jamais utiliser l ’ appareil si: a) son cordon d[...]
-
Page 13
B - 3 5. D ESCRIPTION DE L ’ APP AREIL 5.1 Contenu de l ’ emballage 5.2 El é ments importants de l ’ appareil 1 x Filtre à air additionnel 1 x Cordon d ’ alimentation Accessoires 1 x Circuit 1 x Entonnoir 2 x Chambre d'humidification 1 x humidificateur avec PPC S é rie HC230 CORDON D ’ ALIMENT A TION CIRCUIT 900HC221 CHAMBRE D ’[...]
-
Page 14
B - 4 6. N ETTOY AGE & E NTRETIEN 1. Eteindre l ’ appareil et d é brancher le cor don d ’ alimentation de la prise murale. 2. Essuyer l ’ ext é rieur du l ’ appareil à l ’ aide d ’ un chiffon pr opre humect é d ’ eau (pas mouill é ) et d ’ un d é tergent doux. Ne pas utiliser de produits abrasifs ou solvants risquant d ’[...]
-
Page 15
8. C ONTR Ô LES ET A FFICHAGE B- 5 Bouton mode Naviguer entre les options Bouton Bas Diminue le réglage Bouton Haut Augmente le r é glage Bouton mont é en pression progressive Interrupteur ON/OFF Fran ç ais 8.1 A FFICHAGES : D ESCRIPTION ET F ONCTION BOUTON DESCRIPTION ET FONCTION FONCTIONNEMENT MARCHE /ARRET Mise en marche & arr ê t MODE[...]
-
Page 16
B - 6 8.2 S OMMAIRE M ENU P A TIENT 8.3 S OMMAIRE M ENU P A TIENT : R É GLAGES S UPPL É MENT AIRES MODE Augmenter / diminuer Appuyer pour activer le mode Progressif Affichage Appuyer une fois pour allumer/arr ê ter l ’ appareil Param è tres d ’ humidit é R é glage par d é faut Pression Ajuster l ’ altitude cmH 2 O 0,1,2,3,4 + - 0.5 INC[...]
-
Page 17
DIMENSIONS: 275mm x 170mm x 140mm POIDS: 1.9kg 3.0kg emball é dans un sac comprenant les accessoir es) SPÉCIFICA TIONS ELECTRIQUES Fréquence : 50-60 Hz T ension et Courant: 100-115V (1.2A, max 1.3A), 220-240V (0.8A, max 1.8A) Remarque : Ces valeurs repr é sentent un courant moyen Inversion: 115V - 200W/300W surintensit é 230V – 300W/500W sur[...]
-
Page 18
11. C ONDITIONS DE FONCTIONNEMENT : TEMP É RA TURE AMBIANTE : 5 ° à 35 ° C HUMIDIT É 10 à 95% RH AL TITUDE: 0 à 3000m (9000pieds) Au-dessus de 500m (1500 pieds) la pression maximale sera r é duite. 12. C ONDITIONS D ’ ENTREPOSAGE ET DE TRANSPORT : L ’ appareil doit ê tr e entrepos é et transport é dans une temp é rature ambiante all[...]
-
Page 19
Í NDICE DE MA TERIAS 1. Definici ó n de los s í mbolos ..........................................................................2 2. Advertencias .....................................................................................2 3. Advertencias sobre el uso de ox í geno .................................................................2 4. [...]
-
Page 20
2. A DVERTENCIAS Obs: Este manual se refier e a la unidad CP AP de la Serie HC230 como "el equipo" l. Del equipo deber á n ser utilizados ú nicamente con las mas- carillas, conectores y tubos de suministr o recomendados por Fisher & Paykel Healthcare o por su m é dico o terapeuta respiratorio. 2. Nunca haga functionar l ’ equipo [...]
-
Page 21
C- 3 5. D ESCRIPCI Ó N DEL AP ARA TO 5.1 Contenido del paquete 5.2 Piezas importantes de su sistema del equipo Accesorios 1 x aparato de la serie HC230 CABLE EL É CTRICO TUBO 900HC221 C Á MARA DE AGUA PROTECCI Ó N DE LA C Á MARA PLA TO CALENTADOR MARCA DEL NIVEL DE AGUA PORT AFIL TRO P ANT ALLA FIL TRO DE AIRE BOT Ó N DE ENCENDIDO/AP AGADO 5.[...]
-
Page 22
C - 4 6. L IMPIEZA Y MANTENIMIENTO 1. Apague del equipo y descon é ctelo del tomacorriente. 2. Limpie el exterior del equipo con un trapo limpio y h ú medo (no mojado) y con detergente suave para vajilla. No utilice solventes ni abrasivos fuertes, ya que esto puede da ñ ar al aparato del equipo. 3. DIARIAMENTE Limpie el tubo y la c á mara. • [...]
-
Page 23
8. C ONTROLES Y P ANT ALLA C - 5 Espa ñ ol BOTON DESCRIPCI Ó N Y FUNCI Ó N OPERACI Ó N ENCENDIDO / AP AGADO Encendido y apagado del equipo RAMP A Reduce la presi ó n a un nivel inferior para ayudar el paciente a dormir . La presi ó n volver á gradualmente a la presi ó n de operaci ó n total en 20 minutos AUMENT AR / DISMINUIR Para ajustar [...]
-
Page 24
C - 6 8.2 R ESUMEN M EN Ú P ACIENTE Aumentar / disminuir Presionar el bot ó n para activar rampa Pulsar y mantener presionado para encender/apagar el aparato Pantalla MODO Ajuste de la humedad (ajuste est á ndar) Ajuste de la presi ó n Ajuste de altitud cmH 2 O 0,1,2,3,4 + - 0.5 INCREMENT 8.3 R ESUMEN M EN Ú P ACIENTE : A JUSTES ADICIONALES Au[...]
-
Page 25
DIMENSIONES: 273mm x 170mm x 140mm PESO: 1,9kg (3 , 0kg empaquetados en bolsa incluyendo accesorios) ESPECIFICACIONES EL É CTRICAS Frecuencia de alimentaci ó n: 50-60 Hz V oltaje y corriente de alimentaci ó n: 100-115V (1,2A, m á x. 1,3A), 220-240V (0,8A, m á x. 1,8A) Nota: Estos valores r epresentan la corriente promedio. Invertidor: Sobrevol[...]
-
Page 26
11. C ONDICIONES DE OPERACI Ó N TEMPERA TURA AMBIENTE: 5 ° C a 35 ° C HUMEDAD: 10 a 95% de RH AL TITUD: 0 - 3000m (9000 pies). A m á s de 500m (1500 pies) se reducir á el m á ximo de pr esi ó n de funcionamiento. 12. C ONDICIONES DE ALMACENAMIENTO Y TRANSPORTE El aparato d ’ el equipo deber á almacenarse y transportarse en las siguientes [...]
-
Page 27
Fisher & Paykel Healthcare Offices: INTERNA TIONAL: PO Box 14-348, Panmure, Auckland 1134, New Zealand Email: info@fphcare.com Web Site: www .fphcare.com T el: +64-9-574-0100 Fax: +64-9-574-0158 USA: Suite 101, 22982 Alcalde Drive, Laguna Hills, California 92653, USA T el: +949-470-3900 Fax: +949-470-3933 T oll Free: +1-800-446-3908 AUSTRALIA: [...]