Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fluke 175, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fluke 175 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fluke 175. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fluke 175 should contain:
- informations concerning technical data of Fluke 175
- name of the manufacturer and a year of construction of the Fluke 175 item
- rules of operation, control and maintenance of the Fluke 175 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fluke 175 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fluke 175, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fluke service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fluke 175.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fluke 175 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation. All right s reserved. Printed in USA.[...]
-
Page 2
Lifeti m e Limi ted Warr a n ty Ea c h Fl u k e 20, 70, 80, 17 0 and 18 0 S eri es DM M wil l b e f ree f rom de f e c ts in m a t eri al an d wor k ma n s hi p f or i t s li f e t ime. As u s ed h erein, “li f e- t ime ” is de f ined a s s e v e n y ears a ft e r Fl u k e dis c on t inues man u f ac t uri ng t h e produ c t, b u t t he warran [...]
-
Page 3
i Table of Contents Titl e Page Con tacting Fluk e ............................................................................................................... .... 1 "Warn ing" and "C aution " State ments ..................................................................................... 1 Unsafe Vol tage .................[...]
-
Page 4
ii Warning . Rea d be fore u sing the Mete r: To avoid possible electrical shock or personal injury, follow these guidelines: ⇒ Use the Meter only as spec ified in this ma nual or the pr otection p rovided by t he Meter might be im paired. ⇒ Do not use the Meter or test leads if they appear damaged , or if the Meter is not operating pr operly. [...]
-
Page 5
1 Models 175, 177 & 179 True RMS Multimeters The Fluke Model 175 , Model 177 , and Model 179 are batter y - powered, t rue-RMS m u l t i me t ers (herea ft er " t he Me t er" ) wi t h a 6000- c ount, 3 3/4-di gi t di s play and a bar graph. Thi s manual applies t o al l t hree m odel s . All f igures s how the M odel 179. These meters[...]
-
Page 6
Models 175, 177 & 179 Users M anual 2 Battery Saver ("Sleep Mode") The Meter enters the "Sleep m ode" and blanks t he di s play if t here is no func tion change or but t on press for 20 m inutes. To di s able the Sleep m ode, hol d down t he YELLOW button while t urni ng t he Meter on. The S l eep m ode i s always di s abled[...]
-
Page 7
Displ ay 3 Display . 8 7 7 5 6 4 3 2 1 13 14 15 9 11 12 10 AIK02F.EPS No. Symbol Meaning 1 s Continuit y t est. 2 Diode test . 3 K Negative readi ngs . 4 Y Unsafe v ol t age. Voltage ≥ 30 V , or voltage ov erload ( OL ) 5 Displ ay HOLD is enabl ed. Display freezes pres ent reading. In MIN M AX AV G mode, MI N MAX AVG recordi ng i s interrupted. A[...]
-
Page 8
Models 175, 177 & 179 Users M anual 4 MIN MAX AVG Recording M ode The MIN MA X A VG recording m ode c aptures the m i ni m um and maximum input values , and calc ulates a runni ng av erage of all readings. When a new hi gh or l ow i s detected, the Meter beeps . Note For DC funct i ons , accurac y is the s pecifi ed ac curacy of t he measuremen[...]
-
Page 9
Manual Ranging and Autoranging 5 Manual Ranging and Autoranging The Meter has bot h Manual range and Autorange m odes . ⇒ In the Aut orange mode, the M et er s elects the range with t he best res ol ut i on. ⇒ In the Manual Range m ode, you override A ut orange and select the range yoursel f . When you turn the M eter on, it def aults t o A uto[...]
-
Page 10
Models 175, 177 & 179 Users M anual 6 Making Basic Measurements The figures on t he f ollowing pages s how how to make bas ic measurement s. When connect i ng t he t est leads to the ci rc uit or devi c e, connect the comm on ( COM ) test l ead bef ore c onnecting t he live lead; when removing t he t est leads , remove the l i v e lead before r[...]
-
Page 11
Making Basic Measurem ents 7 Testing for Continuit y RANGE HOLD MIN MA X RANGE HOLD MIN MA X AIK06F.EPS Measuring Temperature (Model 179 Only) RANGE HOLD MIN MAX 80BK1 Type K Thermocouple Probe Vent or Pipe RANGE AIK10F.EPS Warning: Do not connect 80BK1 to liv e c irc uit s . Testing Diodes + __ Forward Bias Single Beep + Reverse Bias Good Diode Go[...]
-
Page 12
Models 175, 177 & 179 Users M anual 8 Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an i n-ci rcuit current measure- ment when the open-circuit potential to earth is > 1000 V. • Check the Meter's fuses before testing. (See “ Testing the Fuses”.) • Use the proper ter[...]
-
Page 13
Using the Bar Graph 9 Measuring Frequency Warning To avoid electrical shock, di sregard the bar graph for frequencies > 1 kHz. I f the frequency of the m easured signal is > 1 kHz, the bar graph is unspecified. The Meter meas ures the frequency of a signal . The trigger level i s 0 V, 0 A A C f or all ranges. + RANGE HOLD MIN MAX Hz RANGE HOL[...]
-
Page 14
Models 175, 177 & 179 Users M anual 10 Cleaning Wipe the cas e with a damp c l ot h and m i l d det ergent. Do not us e abrasives or solvent s . Dirt or m oi s ture in the t erm i nal s can aff ec t readings. Testing the Fuses Warning To avoid electrical shock or injury, rem ove the test leads and any input signals before replacing the fuse. Te[...]
-
Page 15
Specifications 11 Specifications Accuracy is s pec if ied f or 1 y r af t er c alibrat ion, at operat ing t emperatures of 18 ° C to 28 ° C, with relative humidity at 0 % t o 95 %. Ac c urac y specificat ions t ak e t he f orm of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any termi nal and earth gr ound: 1000 V DC or AC RM S Su[...]
-
Page 16
Models 175, 177 & 179 Users M anual 12 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1.[...]
-
Page 17
Specifications 13 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 DC Amps 4 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.0 % + 3 1.0 % + 3 1.0 % + 3 Hz (AC- or DC- coupled, V or A 2, 3 input ) 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 [...]
-
Page 18
Models 175, 177 & 179 Users M anual 14 Function Overload Protection 1 Input Im pe da nc e (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) Normal Mode Rejecti on Volts AC 1000 V RMS > 10 M Ω < 100 pF > 60 dB @ DC, 50 Hz or 60 Hz Volts DC 1000 V RMS > 10 M Ω <100 pF >120 dB @ DC, 50 Hz or 60 Hz > 60 dB @ 50 Hz [...]