FMI F48H(I)(R)A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of FMI F48H(I)(R)A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FMI F48H(I)(R)A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FMI F48H(I)(R)A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FMI F48H(I)(R)A should contain:
- informations concerning technical data of FMI F48H(I)(R)A
- name of the manufacturer and a year of construction of the FMI F48H(I)(R)A item
- rules of operation, control and maintenance of the FMI F48H(I)(R)A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FMI F48H(I)(R)A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FMI F48H(I)(R)A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FMI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FMI F48H(I)(R)A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FMI F48H(I)(R)A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    IF FIREPLACE IS TO BE INST ALLED DIRECTL Y ON ANY COMBUSTIBLE MA TERIAL, A HEARTH SP ACER IS REQUIRED. SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your [...]

  • Page 2

    www .fmipr oducts.com 124386-01A 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury , property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualied installer or local distributor . T ABLE OF CONTENTS Safety ....................................[...]

  • Page 3

    www .fmipr oducts.com 124386-01A 3 SPECIFICA TIONS MODELS F48H(I)(R)A AND VF48H(I)(R)A SQUARE CHASE-TOP TERMIN AT ION ROUND TOP TERMIN AT ION 33.5" 48" 60.625" 42.375" 30.31" PLANT A TION FIREPLACE WITH HEARTH SP ACER (REQUIRED FOR COMBUSTIBLE FLOORS) 24" 14.375" 30" 0.625" 15.625" 8.875" 7.625[...]

  • Page 4

    www .fmipr oducts.com 124386-01A 4 INST ALLA TION SELECTING FIREPLACE LOCA TION T o determine the safest and most efcient location for the replace, you must take into consideration the following guidelines: 1. The location must allow for proper clear - ances (see Figures 1 and 2). 2. Consider a location where the replace will not be affect[...]

  • Page 5

    www .fmipr oducts.com 124386-01A 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the replace opening is required to protect combustible floor construction in front of the replace. Fabricate a hearth extension using a material which meets the following specicat[...]

  • Page 6

    www .fmipr oducts.com 124386-01A 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN (IN) 48" Plantation Fireplace 66 1 / 2 " 12-12DM 12-12HT Pipe Section 10 5 / 8 " 18-12DM 18-12HT Pipe Section 16 5 / 8 " 24-12DM 24-12HT Pipe Section 23 5 / 8 " 36-12DM 36-12HT Pipe Section 34 5 / 8 " 48-12DM 48-12HT Pipe S[...]

  • Page 7

    www .fmipr oducts.com 124386-01A 7 INST ALLA TION Continued USING ELBOW OFFSETS (30E-12DM) 1. T o achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). OFFSET CHART (22-50 FT . SYSTEM HEIGHT) Figure 7 - T ypical Offset T erminations Ret[...]

  • Page 8

    www .fmipr oducts.com 124386-01A 8 INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-10) Firestop spacers are required at each point where chimney penetrates a floor space. Their purpose is to establish and maintain required clearance between chimney and combustible materials. When pipe passes through a framed openin[...]

  • Page 9

    www .fmipr oducts.com 124386-01A 9 INST ALLA TION Continued FLASHING INST ALLA TION (V6F-10DM OR V12F-10DM) Determine ashing to be used with roof open - ing chart. Slide ashing over pipe until base is at against roof. Replace as many shingles as needed to cover exposed area and ashing base. Secure in position by nailing through shingles[...]

  • Page 10

    www .fmipr oducts.com 124386-01A 10 10 FOOT RULE All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through the roof and must be at least 2 feet above highest point of the roof that is within a horizontal distance of 10 feet (see Figure 17). INST ALLA TION Continued FINISHING FIRE[...]

  • Page 11

    www .fmipr oducts.com 124386-01A 11 FIREBRICK WALL INST ALLA TION IMPORT ANT : Installation of brick should be done after the re - place is placed in a permanent location. 1. The replace is shipped with the hearth preinstalled. It is held in place for ship - ping with 3 shipping brackets (Figure 19). Remove these brackets before installing an[...]

  • Page 12

    www .fmipr oducts.com 124386-01A 12 FIREBRICK WALL INST ALLA TION Continued Figure 24 - Installing T op Rear Wall Retaining Bracket 5. Install the rear top rebrick wall. Lift the panel up with the front of the rebrick wall facing toward the front of the replace. The bottom of the panel has two tabs that slide into the bracket on the top of[...]

  • Page 13

    www .fmipr oducts.com 124386-01A 13 INST ALLING GRA TE RET AINERS 1. Place the provided grate retainers on the hearth as shown in Figure 26. The back of the retainer will be ush with the rear rebrick wall. Mark the center of the hole on the hearth with a marker . 2. Drill two holes in the hearth in the marked locations using a masonry 3/16&qu[...]

  • Page 14

    www .fmipr oducts.com 124386-01A 14 Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropri - ate ttings. 1. Remove knockout indentation on refrac - tory or rebrick wall located above refrac - tory hear[...]

  • Page 15

    www .fmipr oducts.com 124386-01A 15 Figure 29 - Securing Door Rails to Fireplace Bottom Rail (Use as a T emplate before Drilling) Concrete Screws T op Rail Drill Holes into Bricks Remove Screws then Replace to Secure T op Rail IMPORT ANT : Install top and bot- tom rails and hardware before installing glass door panels. Rail installation 1 . Remove [...]

  • Page 16

    www .fmipr oducts.com 124386-01A 16 Figure 32 - Adjusting Bi-Fold Doors GLASS DOOR INST ALLA TION Continued Spring Clip Side Front Face Partially Opened Door OPERA TION AND MAINTENANCE GLASS DOORS Glass doors are optional with replace. When replace is in operation, doors must be fully opened or fully closed position only or a re hazard may[...]

  • Page 17

    www .fmipr oducts.com 124386-01A 17 OPERA TION AND MAINTENANCE Continued Figure 34 - Operating Damper Handle Damper Handle Retaining Bracket (Holds Damper Door Closed) Swing Door Down to Open Swing Door Up to Close Secondary Retaining Bracket (Holds Damper Door Open) FULL Y OPEN POSITION FULL Y CLOSED POSITION If you wish to install an unvented (ve[...]

  • Page 18

    www .fmipr oducts.com 124386-01A 18 P ARTS KEY NO. P ART NO. DESCRIPTION QTY . 1 124652-01 Left Leading Brick Red • 1 124652-03 Left Leading Brick Ivory • 1 2 124652-02 Right Leading Brick 36" Red • 1 124652-04 Right Leading Brick 42"/50" Red • 1 3 125634-01 Hearth Red • 1 125634-02 Hearth Ivory • 1 4 124646-01 Rear T op [...]

  • Page 19

    www .fmipr oducts.com 124386-01A 19 ACCESSORIES BI-FOLD GLASS MASONR Y DOOR BDMO48E - 48" Ebony BDMO48G - 48" Pewter BDMO48C - 48" Oiled Bronze DOUBLE W ALL PIPE - 12-12DM, 18-12DM, 24-12DM, 36-12DM, 48-12DM, 12-12HT , 18-12HT , 24-12HT , 36-12HT and 48-12HT 30° OFFSET AND RETURN 30E-12DM and 30E-12HT OPTIONAL OUTSIDE AIR KIT FOR FL[...]

  • Page 20

    124386-01 Rev . A 10/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmiproducts.com ACCESSORIES Continued SQUARE CHASE-TOP TERMINA TION - STL-12D ROUND TOP TERMINA TIONS RL T -12D AND RL T -12HT OPTIONAL HEARTH SP ACER HS48 24" ROUND WOODNOOK - DHR-24 ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch FIR[...]