FMI FVTR24 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of FMI FVTR24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of FMI FVTR24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of FMI FVTR24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of FMI FVTR24 should contain:
- informations concerning technical data of FMI FVTR24
- name of the manufacturer and a year of construction of the FMI FVTR24 item
- rules of operation, control and maintenance of the FMI FVTR24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of FMI FVTR24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of FMI FVTR24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the FMI service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of FMI FVTR24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the FMI FVTR24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NA TURAL GAS LOG WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light [...]

  • Page 2

    2 901846 VENTED NA TURAL GAS LOGS SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others[...]

  • Page 3

    3 901846 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification OPTIONAL PRODUCT FEA TURES ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSION An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this opti[...]

  • Page 4

    4 901846 VENTED NA TURAL GAS LOGS PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation . All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Confined Space [...]

  • Page 5

    5 901846 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between [...]

  • Page 6

    6 901846 VENTED NA TURAL GAS LOGS AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoin[...]

  • Page 7

    7 901846 OWNER’S MANUAL INST ALLA TION WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimn[...]

  • Page 8

    8 901846 VENTED NA TURAL GAS LOGS INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 5. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed. Damper Clamp Damper Clamp Da[...]

  • Page 9

    9 901846 OWNER’S MANUAL INST ALLA TION Continued Figure 8 - Kit Assembly HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly Note: Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. 1. Remove burner inlet fitting from front burner (installed in burner pan, see Fig- ure 8). 2. Make sure ports on front burner [...]

  • Page 10

    10 901846 VENTED NA TURAL GAS LOGS OPTIONAL GA9003 SERIES ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY For additional convenience and safety, or for propane/LP conversion, an optional ON/ OFF safety valve/pilot kit is available. See Accessories , page 17. WARNING: You must use a ON/OFF safety valve/pilot kit for propane/LP conversion. Natural Gas Instal[...]

  • Page 11

    11 901846 OWNER’S MANUAL INST ALLA TION Continued Figure 16 - Burner Inlet Fitting with Injectors BURNER INLET FITTING Injector for Natural Gas Figure 15 - Kit Assembly Burner Inlet Fitting Front Burner Pipe Nipple Air Restrictor Manifold Block Rear Burner Nozzle Figure 17 - Installing Propane/LP Pilot Orifice Pilot Injector Changing Pilot Orific[...]

  • Page 12

    12 901846 VENTED NA TURAL GAS LOGS LIGHTING INSTRUCTIONS OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next t[...]

  • Page 13

    13 901846 OWNER’S MANUAL GAS SHUTOFF VALVE OPERATION Flame Adjustment Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close, as necessary. Shutting Off Appliance Turn gas shutoff valve clockwise to the OFF position. During the 2-3 hour appliance break-in period, you may detect an odor from the app[...]

  • Page 14

    14 901846 VENTED NA TURAL GAS LOGS TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set. POSSIBLE CAUSE REMEDY OBSERVED PROBLEM Note: For additional help, visit DESA International’s technical service web site at www.desatech.com . Note: All troubleshooting items[...]

  • Page 15

    15 901846 OWNER’S MANUAL TROUBLESHOOTING Continued www.desatech.com Continued OBSERVED PROBLEM When ignitor button is pressed, there is no spark at pilot (GA9003 Only) When ignitor button is pressed, there is spark at pilot but no ignition (GA9003 Only) Pilot lights but flame goes out when control knob is released (GA9003 Only) Burner does not li[...]

  • Page 16

    16 901846 VENTED NA TURAL GAS LOGS TROUBLESHOOTING Continued www.desatech.com WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructi[...]

  • Page 17

    17 901846 OWNER’S MANUAL ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-888-2050 for information. You can also write to the ad- dress listed on the back page of this manual. EQUIPMENT SHUTOFF VALVE GA5010 For all models. Equip[...]

  • Page 18

    18 901846 VENTED NA TURAL GAS LOGS ILLUSTRA TED PA R T S BREAKDOWN FVTR18 4 19 21 20 22 23 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17[...]

  • Page 19

    19 901846 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR18 KEY PART NO. NUMBER DESCRIPTION QTY. 1 098249-01 ODS Nut 2 2 901752-02 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-01 Log Grate 1 5 09830[...]

  • Page 20

    20 901846 VENTED NA TURAL GAS LOGS ILLUSTRA TED PA R T S BREAKDOWN FVTR24 4 19 23 21 22 20 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17[...]

  • Page 21

    21 901846 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FVTR24 KEY PART NO. NUMBER DESCRIPTION QTY. 1 098249-01 ODS Nut 2 2 901752-01 Rear Burner 1 3 102843-01 Burner Clip 1 4 901246-02 Log Grate 1 5 09830[...]

  • Page 22

    22 901846 VENTED NA TURAL GAS LOGS NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________[...]

  • Page 23

    23 901846 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________[...]

  • Page 24

    LIMITED WARRANTY FMI VENTED GAS LOGS DESA International warrants this product to be free from defects on burner system for two (2 ) years and logs for a lifetime fro m the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this [...]