Go to page of
Similar user manuals
-
Stove
Foster Pc 380 domino induct. inc-ft
14 pages -
Stove
Foster Professionale.5F.STD
35 pages -
Stove
Foster KE.Line.SF
37 pages -
Stove
Foster S4000.Domino.IS.2
14 pages -
Stove
Foster S4000 Domino.1F.dual.Q4
37 pages -
Stove
Foster S4000.5F.E.Quadra Compatta.Q4
37 pages -
Stove
Foster 7631 032
35 pages -
Stove
Foster KE 79.5F.FT
37 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Foster S4000.Line GS.Q4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Foster S4000.Line GS.Q4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Foster S4000.Line GS.Q4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Foster S4000.Line GS.Q4 should contain:
- informations concerning technical data of Foster S4000.Line GS.Q4
- name of the manufacturer and a year of construction of the Foster S4000.Line GS.Q4 item
- rules of operation, control and maintenance of the Foster S4000.Line GS.Q4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Foster S4000.Line GS.Q4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Foster S4000.Line GS.Q4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Foster service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Foster S4000.Line GS.Q4.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Foster S4000.Line GS.Q4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com USER'S MANUAL FOR GAS COOKER HOBS Ab stra c t cod. 9606801[...]
-
Page 2
20 ENGLISH T able of Contents 1. Usage warnings ................................................................................................................... 21 2. Safety warnings .................................................................................................................... 22 3. Warnings for disposal ...................[...]
-
Page 3
21 ENGLISH GENERAL WARNINGS 1. Usage warnings This manual is and integral part of this appliance. It is necessary to keep it undamaged and on hand for the entire life cycle of the hob. We recommend carefully reading this document and all instructions contained within before using the appliance . Installation must be completed by qualified personne[...]
-
Page 4
22 ENGLISH GENERAL WARNINGS 2. Safety warnings In your interest and for your safety , by law it has been established that instal - lation and service for all electric or gas appliances must be carried out by qualified personnel, according to current regulations and the require - ments of local companies supplying gas and electric power . • Ga[...]
-
Page 5
23 ENGLISH GENERAL WARNINGS disposed of correctly . Contact your reseller or competent organizations in your area for information about waste collection centres, recycling and disposal. DO NOT ABBANDON THE P ACKAGING MA TERIAL OR PAR TS OF IT . THEY MA Y CREA TE A SUFFOCA TION DANGER FOR CHILDREN, ESPECIALL Y PLASTIC BAGS. Even your old appliance m[...]
-
Page 6
24 ENGLISH INST ALLER INSTRUCTIONS ENGLISH 5. First installation Do not leave packaging material waste unguarded in the household environment. Separate the various packaging waste materials and deliver them to the closest selective waste collection centres. In order to remove all manufacturing residues, we recommend cleaning the appliance. For furt[...]
-
Page 7
25 ENGLISH INST ALLER INSTRUCTIONS • The distance of the cooker hob from the back edge must be at least 50mm; • The distance of the cooker hob from the walls that exceed worktop height must be at least 100 mm; • Should a hood be installed above the hob, see the hood assembly instructions which provide the correct distance to be re[...]
-
Page 8
26 ENGLISH INST ALLER INSTRUCTIONS • Accurately clean milling. • Before positioning the top, lay the sealer gasket provided on the entire milling surface [ Fig. 5 ]. • Once these operations have been completed, use the supplied brackets to fasten the hob to the structure. Re- fer to the “ Fastening the cooker hob to the cabinet ”[...]
-
Page 9
27 ENGLISH INST ALLER INSTRUCTIONS 7.1 Fixed hooks They make it possible to fasten the cooker hob using fixing frames pre-set along specific points. Standard edge (8 mm) Q4 edge (4 mm) Semi-flush edge (3 mm) Flush-mount edge[...]
-
Page 10
28 ENGLISH INST ALLER INSTRUCTIONS Set hook B in frame A welded to the hob, making sure that it is blocked in the spe - cific holes based on top thickness (for a 30 mm thick top, lock the hook in the the highest hole in the frame; for a 40 mm thick top, block the hook in the lowest hole of the frame). Rotate tongue CA until it is positioned above [...]
-
Page 11
29 ENGLISH INST ALLER INSTRUCTIONS 7.3 Fixed brackets Make it possible to fasten the cooker hob in pre-set fastening points. Standard edge (8 mm) A B Introduce the bracket B in appropriate top seat. Manually lock the bracket using screw A. 8. Connecting the cooker hob to the gas network It is necessary for the gas supply system to conform to local [...]
-
Page 12
30 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : Always place the gasket between the hob fitting and the connection pipe. • If using a stainless steel flexible pipe , it must be installed so that it does not come in contact with any part of the cabinet, but passes through an unoccupied area where its entire length can be inspected. Maximum ex[...]
-
Page 13
31 ENGLISH INST ALLER INSTRUCTIONS 10. Discharging combustion products (exhaust) Discharge of combustion products must be ensured through hoods connected to an efficient natural draught flue, or through a forced exhaust. An efficient exhaust system requires an accurate design by a specialist that is ap - proved for this work, following positions[...]
-
Page 14
32 ENGLISH INST ALLER INSTRUCTIONS Gas type Burner Nominal power (KW) Rated con- sumption (g/h) Injector (ø mm) Min. nominal power (KW) Series No. Ref. METHANE GAS G20 20 mbar II 2 Auxiliary 1,00 95 0,72 0,52 3 Semi-quick 1,75 167 0,97 0,52 4 Quick 2,70 257 1,08 0,90 5 T riple crown 3,50 333 1,35 1,80 10 Dual 4,50 429 i 0.72 / and 1.02 i 0.46 / an[...]
-
Page 15
33 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : After adjusting for use with a gas that is different from the initial testing one, replace the label on appliance housing with the one that corresponds to the new gas type. 12. Adjustment of the minimum Instructions for urban and methane gas 1. Light the burner and bring it to the minimum position. 2.[...]
-
Page 16
34 ENGLISH USER INSTRUCTIONS It is mandatory to have an earth connection as per modes foreseen in the electrical system safety standards. • For direct connection to the electric mains, a device must be applied which guar - antees disconnection from the mains with a contact opening distance which al - lows complete disconnection in overvoltage [...]
-
Page 17
35 ENGLISH USER INSTRUCTIONS The upper cover (B) of the burners must be placed in opposite seat with the two intro - ductions notches in correspondence of the two cylinders below (C) and tighten clock - wise. The associated burner is indicated near each knob. The appliance is equipped with an electric ignition device. It is sufficient to press the[...]
-
Page 18
36 ENGLISH USER INSTRUCTIONS 14.2 Practical recommendations for burner use For better burner yield, and minimum gas consumption, it is necessary to use flat and regular bottom pots, equipped with a cover and proportioned to the burner , in order to avoid that the flame goes up their sides (see the “Pots diameter” paragraph [ Page 36 ]). When [...]
-
Page 19
37 ENGLISH USER INSTRUCTIONS 15. Cleaning and maintenance Do not use a steam jet to clean the appliance. Before any intervention it is necessar y to disengage the appliance power supply . Avoid leaving acid or alkaline (vinegar , lemon juice, salt, tomato juice,...) substances on the steel, grids and other parts of the appliance. 15.1 Cleaning the [...]
-
Page 20
182 Riepilogo piani cottura a gas Legenda Serie N. Bruciatore Potenza (W) 1 Manopola di comando II 2 Ausiliario 1.000 3 Semirapido 1.750 4 Rapido 2.700 5 T ripla corona 3.500 10 Dual 4.500 III 6 Ausiliario 1.100 7 Semirapido 1.750 8 Rapido 3.000 9 T ripla corona 3.800 AE 11 Ausiliario 1.100 12 Semirapido 1.750 13 Rapido 3.000 14 Doppia corona 5.000[...]
-
Page 21
187 1.1 4000 1 6 7 7 8 9 9 N7272V A = 1160 mm B = 480 mm N7272V 1200 1221 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 +1 0 1 6 7 7 8 9 N7252V A = 860 mm B = 480 mm N7252V 900 921 +1 0 500 521 R10.5 10.5 1.5 +1 0 +1 0 +1 0 1 7 7 6 8 9 N7270V A = 860 mm B = 480 mm N7270V 900 921 +1 0 500 521 R10.5 10.5 1.5 +1 0 +1 0 +1 0[...]
-
Page 22
188 1 8 6 7 7 8 7 N7253V A = 830 mm B = 480 mm N7253V 830 851 +1 0 500 521 +1 0 R10.5 10.5 1.5 +1 0 +1 0 6 7 7 8 1 N7251V A = 560mm B = 480 mm N7251V 600 +1 0 621 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 1 6 9 7 8 N7254V A = 1159 mm B = 348 mm N7254V 1180 +1 0 369 +1 0 1162 351 9 1.5 R10.5 +1 0 +1 0 N7254V A = 1162 B = 351 mm[...]
-
Page 23
189 1 14 N7278V-AEO A = 430 mm B = 480 mm 1 10 N7277V A = 430 mm B = 480 mm 1 12 11 N7276V-AEO A = 360 mm B = 480 mm[...]
-
Page 24
190 1.2 QUADRA 1 2 5 3 4 N7215V A = 1162 mm B = 351 mm N7214V 1180 +1 0 369 +1 0 1162 351 +1 0 9 1.5 R10.5 +1 0 1 2 5 3 N7211V A = 862 mm B = 351 mm N7211V 369 +1 0 351 +1 0 R10.5 9 1.5 926 +1 0 908 +1 0 1 3 N7221V A = 309 mm B = 454 mm N7221V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.5[...]
-
Page 25
191 1 5 N7223V A = 309 mm B = 454 mm N7223V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.5 1 1 2 5 2 4 3 N7238V 351 +1 0 955.5 +1 0 157.8 +1 0 45° 955.5 +1 0 351 +1 0 N7238V 369 351 R10.5 955.5 +1 0 973.5 157.8 9 9 9 9 R9.5 R10.5 45° 9 1.5 +1 0 +1 0 +1 0 +1 0[...]
-
Page 26
192 1.3 KE 1 6 6 7 7 9 N7603VKE A = 840 mm B = 480 mm N7600VKE 7 1.5 500 +1 0 514 +1 0 790 +1 0 804 +1 0 R10.5 N7600VKE N7600VKE A = 770 mm B = 480 mm 1.4 KS 1 6 7 7 7 9 N7610V A = 770 mm B = 480 mm 1 1 6 8 7 7 N7615V A = 560 mm B = 480 mm[...]
-
Page 27
193 1.5 PROFESSIONALE 1 2 3 3 4 5 N7055V-10 N7055V-10 A = 840 mm B = 480 mm N7055V-10 7 1.5 500 514 R10.5 860 874 +1 0 +1 0 +1 0 +1 0 1 2 3 5 N7053V-10 A = 560 mm B = 480 mm N7053V-10 500 514 R10.5 590 604 +1 0 7 1.5 +1 0 +1 0 +1 0 1 2 3 N7062V-08 A = 270 mm B = 480 mm[...]
-
Page 28
194 1 5 N7061V-08 A = 270 mm B = 480 mm 1.6 LISA 1 5 8 7 7 6 N7290V 828.8 587 506.8 R93.5 200.5 303 R161 R1262.5 N7290V 828.8 842.8 +1 0 587 +1 0 601 +1 0 506.8 7 1.5 R100.5 R93.5 200.5 303 R161 R168 R1269.5 R1262.5 +1 0[...]
-
Page 29
195 1.7 F AUST 1 2 3 3 3 5 N7075V N7048V A = 770 mm B = 480 mm N7047VFT1 7 1.5 500 514 +1 0 790 804 R10.5 +1 0 +1 0 +1 0 1.8 ELEONORA 1 2 3 3 3 5 N7095V A = 770 mm B = 480 mm N7295V 770 480 R135 N7296VFT R152 R145 7 1.5 500 514 860 874 +1 0 +1 0 +1 0 +1 0[...]
-
Page 30
196 1.9 VULCANO 1 3 10 10 N7097V A = 950 mm B = 480 mm N7297V R152 R145 7 1.5 500 514 +1 0 970 984 +1 0 +1 0 +1 0 1.10 VERONIKA 1 2 4 5 3 3 N7067V A = 560 mm B = 480 mm 1 4 3 3 2 N7066V A = 560 mm B = 480 mm[...]
-
Page 31
197 1 8 7 6 N7063V A = 420 mm B = 480 mm 1 6 7 7 8 8 N7367V 500 +1 0 514 +1 0 760 774 +1 0 R152 R145 7 1.5 +1 0 1 1 6 8 7 7 N7266V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145[...]
-
Page 32
198 1.11 ELETTRA - P ANDORA 1 2 4 5 3 3 N7064V A = 560 mm B = 480 mm 1 2 4 5 3 3 N7065V A = 560 mm B = 480 mm 1.12 MAGIC 1 2 3 3 4 N7024V A = 740 mm B = 480 mm N7044V 500 +1 0 514 +1 0 760 +1 0 774 +1 0 R152 R145 7 1.5[...]
-
Page 33
199 1 4 5 3 N7021V A = 740 mm B = 480 mm 1 2 4 3 3 N7023V A = 560 mm B = 480 mm N7042V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145 1.13 ALIEN 1 3 5 4 N7017V A A = 840 mm B = 480 mm[...]
-
Page 34
200 1.14 ANGOLARE 1 2 3 5 3 3 N7038V 619 810 330 480 20x45° 810 191x45° 619 810 +4 0 480 +4 0 +4 0 +4 0 +4 0 1.15 F2000 1 2 3 5 N7053000V A = 560 mm B = 480 mm 1 2 3 3 4 5 N7055000V A = 840 mm B = 480 mm[...]
-
Page 35
201 1.16 RONDÒ - GIOTTO 1 4 2 3 N7052V Ø 500 mm 1 10 N7051VG Ø 500 mm 1.17 ALF A 1 6 7 5 8 7 N7260V N7260V A = 840 mm B = 480 mm N7260V 7 1.5 500 +1 0 514 +1 0 R10.5 860 +1 0 874 +1 0[...]
-
Page 36
202 1.18 GK 14 12 12 11 1 1 GK4F A = 1030 mm B = 450 mm GK4F 1030 +1 0 1051 +1 0 450 +1 0 471 +1 0 R10.5 10.5 1.5[...]
-
Page 37
Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com cod. 9606801 Rev . 01 - 04/2012[...]