Freecom Technologies RCS-M1000T manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Freecom Technologies RCS-M1000T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Freecom Technologies RCS-M1000T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Freecom Technologies RCS-M1000T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Freecom Technologies RCS-M1000T should contain:
- informations concerning technical data of Freecom Technologies RCS-M1000T
- name of the manufacturer and a year of construction of the Freecom Technologies RCS-M1000T item
- rules of operation, control and maintenance of the Freecom Technologies RCS-M1000T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Freecom Technologies RCS-M1000T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Freecom Technologies RCS-M1000T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Freecom Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Freecom Technologies RCS-M1000T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Freecom Technologies RCS-M1000T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    Models RCS-M1000T RCS-M1000U IMPOR T ANT NO TICE: T o av oid damage and v oiding y our warr anty , place the unit in its upright position f or a minimum of two hours bef ore oper ating. F or best results, and more enjo yment from y our ne w FREECOM por table air conditioning unit, please read this instruction manual carefully and sav e f or future [...]

  • Page 3

    FEA TURES Thank you f or purchasing the FREECOM RCS-M1000 P or table Air Conditioner . The RCS-M1000 series P or tab le Air Conditioner is designed with many state-of-the art features: • Quiet, durab le caster wheels allow f or easy mov ement and instant spot cooling in any room. • Conv enient, electronic operation panel enab les one-touch cont[...]

  • Page 4

    TROUBLESHOO TING Before contacting a dealer or qualified service technician, please read and check the fol- lowing: SOLUTION 1. Make sure city power supply is normal. 2. Check plug is correctly installed into outlet. 3. Check fuses and household breaker s witches. 4. Remov e electrical plug from outlet. Check electri- cal cord and plug f or damage.[...]

  • Page 5

    MAINTENANCE AND CLEANING (contd.) Cleaning Cabinet Exterior W ARNING: ELECTRICAL SHOCK HAZARD: • T ur n off unit and unplug from wall outlet bef ore cleaning. • Ne ver submerse the unit in w ater or expose to hea vy moisture. • Ne ver pour w ater directly onto the unit. • Ne ver use brushes, brooms , harsh detergents, chemicals, solv ents ,[...]

  • Page 6

    TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE. DO NOT OPEN CABINET . DANGEROUS HIGH VOL T AGE IS PRESENT . REFER SERVICING ONL Y T O QUALIFIED PERSONNEL. Y our air conditioner contains a refrigerant which is converted from a gas to a liquid by a highly efficient compressor . It has been designed to operate[...]

  • Page 7

    4 TRES IMPORT ANT INSTRUCTIONS DE SECURITE A lire attentivement avant utilisation Sécurité • Ne pas arrêter l'appareil en débranchant la prise de courant en cours de f onctionnement. Ceci pourrait endommager le circuit de contrôle (dommage e xclu de la gantie). Utilisez toujours le bouton "ON/OFF" du tableau de commande . • [...]

  • Page 8

    MAINTENANCE AND CLEANING (contd.) Cleaning Air Filters This unit has two air filters. F or best results and maximum perf ormance, clean both filters e very two weeks, or as required b y environmental conditions . CAUTION: Neglect or f ailure to regularly clean the filters will result in poor efficiency , reduced perf or mance , possible damage to t[...]

  • Page 9

    MAINTENANCE AND CLEANING Emptying Condensate W ater T ank When the condensate water tank is full, the “FULL T ANK” indicator light will flash,the unit will sound se ver al initial warning beeps, and the unit will automatically turn off. NOTE: If emptying water tank bef ore “full tank” alert, press “PO WER ON/OFF” button to stop unit if [...]

  • Page 10

    IMPORT ANT SAFETY INFORMA TION PLEASE READ AND FOLLO W ALL SAFETY INFORMA TION AND INSTR UCTIONS BEFORE OPERA TING Y OUR NEW FREECOM AIR CONDITIONER. W ARNING: ELECTRICAL SHOCK HAZARD . F ailure to f ollow the saf ety inf ormation below can result in se vere personal injury or proper ty damage. • Use this product only with the proper electrical v[...]

  • Page 11

    PRODUCT P AR TS FRONT VIEW REAR VIEW B E D A G F I C J A E F J L K H M A. Control Panel B. Horizontal Air Louver (up and down) C. Air Outlet D. V ertical Air Louver (left to right) E. Built-in Handle F . Air Filters G . Condensate Water T ank H. Power Cord I. Plug J. Caster Wheels K. Power Cord Wrap L. Exhaust V ent and Duct Hose Opening M. Exhaust[...]

  • Page 12

    A CCESSOR Y INST ALLA TION Exhaust Duct Kit The Exhaust Duct Kit is an accessor y which, when used with the RCS-M1000 series air conditioning units, will increase cooling efficiency b y directing warm air exhaust out of the room. The Exhaust Duct Kit can be used with other F reecom accessories, such as the Window P anel V ent Kit, Sliding Door V en[...]

  • Page 13

    OPERA TION (contd.) Dehumidifying W ARNING: DO NO T use Exhaust Duct Kit when operating as a dehumidifier . 1. Plug power cord into a standard household outlet. Use this product only with the proper electrical voltage. W ARNING: Do not plug this appliance into an outlet that is being used by other appliances or electrical devices . When installing [...]

  • Page 14

    THE CONTROL P ANEL 1. POWER ON/OFF Easy push-button control s witch to turn the unit ON and OFF 2. AIR VOLUME There are five diff erent air volume selections: •H I • HI RHYTHM •L O • LO RHYTHM • DEHUMID . 3. TIMER Adjustable 3 hour timer can be prog rammed to turn off air conditioner after 1, 2, or 3 hours 4. AUTO LOUVER Choose between fi[...]

  • Page 15

    BEFORE USING IMPORT ANT : Remov e unit from packaging and discard clear , plastic wrapping. Place unit in its upright position for a minimum of tw o hours bef ore operating f or the first time. 1. Place unit on a solid, lev el surface . Operating this unit on une ven or soft surf aces may cause vibr ation, noise, and possible w ater leakage from th[...]

  • Page 16

    OPERA TION CAUTION: T o avoid damage and v oiding y our warranty , place unit in its upright position f or a minimum of two hours bef ore operating. DO NO T operate unit without condensate water tank and air filters properly in place. Cooling This unit is intended to cool a 100-120 s.f . area. The unit’s cooling capacity will v ary according to r[...]