Go to page of
Similar user manuals
-
Air Conditioner
Friedrich SV10A10
27 pages 1.01 mb -
Air Conditioner
Friedrich 2004
40 pages 0.54 mb -
Air Conditioner
Friedrich WE10
20 pages 0.57 mb -
Air Conditioner
Friedrich WS10B10A-C
30 pages 0.83 mb -
Air Conditioner
Friedrich WE16
44 pages 8.23 mb -
Air Conditioner
Friedrich MS36Y3F
25 pages 2.26 mb -
Air Conditioner
Friedrich US14C30
31 pages 2.75 mb -
Air Conditioner
Friedrich MR36C3F
24 pages 1.4 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Friedrich P09A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Friedrich P09A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Friedrich P09A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Friedrich P09A should contain:
- informations concerning technical data of Friedrich P09A
- name of the manufacturer and a year of construction of the Friedrich P09A item
- rules of operation, control and maintenance of the Friedrich P09A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Friedrich P09A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Friedrich P09A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Friedrich service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Friedrich P09A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Friedrich P09A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Ser vice Manual Portable Air Conditioner PORT -ServMan (04-09) Model: P09A P09B P012A P012B[...]
-
Page 2
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. TECHNICAL SUPPORT CONT ACT INFORMA TION[...]
-
Page 3
T able Of Contents Important Safety Information ....................................................................................................................2-4 Introduction ..................................................................................................................................................4 Unit Introduction ...[...]
-
Page 4
IMPORT ANT SAFETY INFORMA TION The information contained in this manual is intended for use by a qualied service technician who is familiar with the safety procedures required for installation and repair , and who is equipped with the proper tools and test instruments required to service this product. Installation or repairs made by unqualied[...]
-
Page 5
Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, • and sleeve on the room side of the air conditioning unit while cleaning. Electrical component malfunction caused by water could result in electric shock or other electrically • unsafe conditions when the power is restored and the u[...]
-
Page 6
PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS: Read the Installation/Operation Manual for this air conditioning unit prior to operating. • Use air conditioner on a single dedicated circuit within the specied amperage rating. • Connect to a properly grounded outlet only . • Do not remove ground prong of plug. • Do not cut or mod[...]
-
Page 7
UNIT INT RODUCTION 5 1. Control panel 2. Air outlet 3. Signal receptor 4. Hand le 5. Caster 6. Air outlet hose 7. Air lter 8. Air intake hose 9. 1/2" water outlet drain 10. Power supply cord[...]
-
Page 8
6 Portable 2nd and 3rd DIGIT - Approximate BTU/HR (Cooling) Heating BTU/Hr capacity listed in the Specication/Performance Data Section Design Series Serial Number Decade Manufactured L=0 C=3 F=6 J=9 A=1 D=4 G=7 B=2 E=5 H=8 Y ear Manufactured A=1 D=4 G=7 K=0 B=2 E=5 H=8 C=3 F=6 J=9 Month Manufactured A=Jan D=Apr G=Jul K=Oct B=Feb E=May H=Aug L=No[...]
-
Page 9
TECHNICAL SPECIFICA TIONS P09A AND P12A 7 Model Co olin g Capac ity BTU/h Vo ltag e / Hz Amps Watt s Dimensions (W ” x H ” x D”) Dehumidica tion (Pints/Hour) Ind oor A ir Circulation (CFM ) Refri gerant Ch ar ge) (R- 22) Locked Rotor Amps Net Weigh t (lbs.) Circuit Rating Plu g Face (NEMA #) P09A 8900 1 15/60 8 923 19.5” x 33.6” x 15.5[...]
-
Page 10
PRECA UTIONS FOR USE 8 Make sure the unit is installed in an accessible location. • Do not locate the unit in direct sunlight so as to avoid discoloration of the plastic. • Keep the unit 1 meter away from television sets or radios to avoid the risk of electromagnetic interference. • Ensure that the discharge air outlet is free from o[...]
-
Page 11
CONTR OL P ANEL OPERA TION 9 Dehu midif ying an d cooling operation The o perating rang e for c ooling op eration is 60 °F - 9 0°F , and the ope rating range for dehumidif ying is 6 8°F - 88° F . Power sour ce • The AC socket must be rm and re liable. • D on ’t connect the por tabl e air conditi oner to a multiple socket out le t whic [...]
-
Page 12
10 REMO TE CONTROL Used for adjusting the timer and • temperature The default display on control • panel is room temperature. When the " • " or the " " button is pressed in cool mode, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. T imer setting is a[...]
-
Page 13
4 Window adapter kit Window Panel Instructions for assembling the window adapter kit 1. Insert tube adapters through the back of the window panel. 2. Secure each tube adapter with four screws through the front of the window panel. 3. Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensi[...]
-
Page 14
5 Window installation Maintain a clear distance (from walls, furniture, etc.) of at least 10 inches ar ound the unit to allow pr oper air cir culation and prevent damage to the unit. Important: Do not over -stretch the exhaust tube or make any unnecessary bends in it. Installing the window adapter kit Note: The window adapter kit must be installed [...]
-
Page 15
Y our ZoneA ire ® P o r t a b l e A i r C o n d i t i o n e r i s d e s i g n e d t o ev ap orate the c ondensation removed from the interio r spac e through the exhaust hose. Under cer tai n conditi ons it is possib le that the unit will not evaporate 100% of the remov ed mo istu re. The unit i s de signed with a built-in reser voir to ac cumulat[...]
-
Page 16
MAINTENANCE / SER VICE Unplug and/or disconnect all electrical power to the unit before performing inspections, maintenances or service. Failure to do so could result in electric shock, serious injury or death. W ARNING RISK OF ELECTRIC SHOCK P reparation for storage 1 . T urn of f the air c onditioner , disco nnect the power . 2. Per form proper m[...]
-
Page 17
TROUBLESHOO TING 15[...]
-
Page 18
16 TROUBLESHOO TING The compressor bolts are loose or copper tubes are contacting other metal parts T ighten bolts Adjust copper tubes Unblock (below72 F)[...]
-
Page 19
17 REFRIGERA T OR SY STEM DIAGRAM SCHEMA TIC WIRING DIAGRAM[...]
-
Page 20
18 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com PORTABLE AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR AN Y PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no [...]
-
Page 21
[...]
-
Page 22
20[...]
-
Page 23
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. TECHNICAL SUPPORT CONT ACT INFORMA TION[...]
-
Page 24
FRIEDRICH AIR CONDITIONING CO . Post Ofce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4490 www .friedrich.com Printed in the U.S.A. PORT -ServMan (04-09)[...]