Go to page of
Similar user manuals
-
Air Conditioner
Friedrich 18
20 pages 0.57 mb -
Air Conditioner
Friedrich UE08, UE10, UE12
23 pages 0.85 mb -
Air Conditioner
Friedrich Twintemp YS09
56 pages 2.19 mb -
Air Conditioner
Friedrich SQ06N10
67 pages 9.56 mb -
Air Conditioner
Friedrich PE12K**B
12 pages 0.28 mb -
Air Conditioner
Friedrich Room Air Conditioner
59 pages 12.42 mb -
Air Conditioner
Friedrich CP08E10
30 pages 2.89 mb -
Air Conditioner
Friedrich WS14B10A-C
30 pages 0.83 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Friedrich SV12A10, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Friedrich SV12A10 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Friedrich SV12A10. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Friedrich SV12A10 should contain:
- informations concerning technical data of Friedrich SV12A10
- name of the manufacturer and a year of construction of the Friedrich SV12A10 item
- rules of operation, control and maintenance of the Friedrich SV12A10 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Friedrich SV12A10 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Friedrich SV12A10, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Friedrich service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Friedrich SV12A10.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Friedrich SV12A10 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Room Air Conditioner Ser vice and P ar ts Man ual Slider Casement SV08 / SV10 / SV12 (01/03) 115V olts • SV08A10 • SV10A10 • SV12A10 High Cool Med Fan Off Mode Temperature Med Cool Low Cool Low Fan Cooler Warmer[...]
-
Page 2
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES......................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1[...]
-
Page 3
—3— POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (BTU/W . h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP. CONTROL AIR DIRECTION CONTROL CONSTRUCTION PROTECTOR COMPRESSOR FAN MOTOR POWER CORD DRAIN SYS[...]
-
Page 4
—4— 1.4 FEA TURES • Designed for COOLING ONLY. • Powerful and whispering cooling. • Simple installation and service. • Low air-intake, top cooled-air discharge. 1.5 CONTR OL LOCA TIONS 1.5.1 COOLING ONL Y MODEL • VENTILATION The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When a fr[...]
-
Page 5
— 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward and remove the air filter. 2. Remove the screws which fasten the front grille.(See Figure 1) 3. Pull the front grille from the right side. 4. Remove the front grille.(There are 4 hooks.) 5. Re-install the components by referring to the removal procedure, above. 2.[...]
-
Page 6
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 4 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the upper air guide. (See F[...]
-
Page 7
— 7 — 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Figure 8) 3. Re-install the components by referring to the removal procedure, above. 2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the termi[...]
-
Page 8
— 8 — 2.3.3 CAP A CIT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the screw and the clamp which fastens the capacitor. 3. Disconnect all the leads of capacitor terminals. 4. Re-install the components by referring to the removal procedure, above. (See Figure 11) 2.3.4 PO WER CORD 1. Remove the cabinet. (Refer to section 2.1.2) 2[...]
-
Page 9
— 9 — 2.3.7 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the turbo fan. (Refer to section 2.2.1) 3. Remove the fan. (Refer to section 2.2.2) 4. Remove the 4 screws which fasten the motor from the Motor Mount. (See Figure 15) 5. Remove the motor. 6. Re-install the components by referring to the removal procedure, above.(See [...]
-
Page 10
— 10 — — Replacement of the refrigerant. 1. When replacing the refrigerant, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after servicing the system. 2. After discharging [...]
-
Page 11
— 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MAN[...]
-
Page 12
— 12 — 3. INST ALLA TION 3.1 HO W T O INST ALL THE UNIT 1. To avoid vibration and noise, make sure the unit is installed securely and firmly. 2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet. 3. There should be no obstacle, like a fence, within[...]
-
Page 13
— 13 — 3.4 WINDO W REQUIREMENTS 1. These instructions are for a horizontal sliding or a casement window. 2. The electrical outlet must be within reach of the power cord. For installation in a casement window, the window frame assembly and the side of the building must be adequate to support the weight of the air conditioner. 3.5 INST ALLA TION [...]
-
Page 14
—14— 1. Loosely attach the support bracket to the bottom of bracket using bolts, washers, and nuts. Attach the leveling bolt and nut. (See Figure 22) 2. Remove protective backing from window track seal and apply seal to window track. (See Figure 23) 3. Measure and lightly mark a line 8-1/4 inches from window jamb. Center the support bracket ass[...]
-
Page 15
— 15 — 8. Slide curtain into curtain frame. Slide curtain frame assembly into side guides of the air conditioner cabinet. Make sure curtain is firmly enclosed on all sides by the frame. (See Figure 27) 9. Cut side guide seal into 2 equal lengths. Remove protective backing and apply it to the rear side of cabinet side guides, starting just below[...]
-
Page 16
— 16 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 368(14 1 / 2 ) 521(20 1 / 2 ) 607(23 3 / 5 ) CAPILLARY TUBE COMPRESSOR TURBO F AN EV APORA TOR COIL CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig. 31 to follow the refr[...]
-
Page 17
— 17 — 4.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling Check ou[...]
-
Page 18
— 18 — Fails to Start Check circuit break er and fuse. Gas leakage of f eeler bulb of ther mostat Check of control s witch. F an only fails to start. Improper wiring. Def ect of f an motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of f an motor . T ests nor mal but f ails to star t. Replacement of c[...]
-
Page 19
— 19 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identification. R[...]
-
Page 20
— 20 — COMPLAINT CAUSE REMEDY Check the position of knob If not at the coldest setting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace thermostat if circuit is open. Check the capacitor. Replace if not within ±10% of manufacturers rating. Replace if shorted, open, or damaged. Check the compressor[...]
-
Page 21
5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM ■ MODEL : SV10A10 / SV12A10 — 21 — SV10A10 SV12A10 PART NO. 1 POWER CORD 6411A20011N 6411A20011P 1 S 2 ROTARY SWITCH 2H00598E 1 S 3 FAN MOTOR 4681A20069C 1 S 4 CAPACITOR 6120AR2194P 0CZZA20001N 1 S 5 THERMOSTAT 2H01109Q 1 S 6 COMPRESSOR 2520UKAC2GA 2520UKGC2DA 1S LOCATION NO. DESCRIPTION RE- MARKS Q[...]
-
Page 22
— 22 — 5.2 CIRCUIT DIA GRAM ■ MODEL : SV08A10 SV08A10 PART NO. 1 POWER CORD 6411A20011L 1 S 2 ROTARY SWITCH 2H00598E 1 S 3 FAN MOTOR 4681A20069A 1 S 4 CAPACITOR 6120AR2359H 1 S 5 THERMOSTAT 2H01109M 1 S 6 COMPRESSOR 2520UAGC2AA 1S LOCATION NO. DESCRIPTION RE- MARKS Q'TY PER SET S: Service Parts N: Non Service Parts[...]
-
Page 23
6. EXPLODED VIEW — 23 — 554030 148000 352390 349001 349600 346811 354210 152312 147581 145200 147582-2 135312 147582-1 135301 264110 269310 266003 249950 130910 359011 130410 552111 352113 352380 149980 W0CZZ 567502 554160 550140 349480 135303 359012 352115 35211A 149410 H i g h C o o l M e d F a n O f f M o d e M e d C o o l L o w C o o l L o [...]
-
Page 24
— 24 — 7. REPLA CEMENT P AR TS LIST ■ MODEL : SV08A10, SV10A10, SV12A10 P/No SV08A10 SV10A10 SV12A10 130410 BASE ASSY, SINGLE 3041A20033J 3041A20033N R 130910 CABINET ASSY, SINGLE 3091A20014A R 135303 GRILLE INLET 3530A20056A R 135312 GRILLE ASSY, FRONT 3531A20123A R 147581 VANE, HORIZONTAL 4758A20032A R 147582 VANE, VERTICAL 4758A20017A / 47[...]
-
Page 25
— 25 — MEMO[...]
-
Page 26
— 26 — MEMO[...]
-
Page 27
Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20190G SV08 / SV10 / SV12 (01/03) Use F actor y Cer tified P ar ts...[...]