Go to page of
Similar user manuals
-
Fryer
Frymaster FPPH255
2 pages 0.2 mb -
Fryer
Frymaster 2836 Series
30 pages 0.73 mb -
Fryer
Frymaster 8196428
40 pages 4.65 mb -
Fryer
Frymaster HCP
30 pages 2.6 mb -
Fryer
Frymaster D280G
2 pages 0.3 mb -
Fryer
Frymaster J65X
88 pages 3.4 mb -
Fryer
Frymaster FPHD
76 pages 6.55 mb -
Fryer
Frymaster GF40
26 pages 0.81 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Frymaster 8196345, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Frymaster 8196345 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Frymaster 8196345. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Frymaster 8196345 should contain:
- informations concerning technical data of Frymaster 8196345
- name of the manufacturer and a year of construction of the Frymaster 8196345 item
- rules of operation, control and maintenance of the Frymaster 8196345 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Frymaster 8196345 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Frymaster 8196345, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Frymaster service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Frymaster 8196345.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Frymaster 8196345 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Frymaster, a member of the Co mmercial Food Equipm ent Serv ice Association, recommends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 FEBRUARY 2009 www.frymaster.com E-mail: service@frymaster.com *8196345* PROTECTOR ® SERIES GAS FRYERS Service & Parts Manual[...]
-
Page 2
ii NOTICE IF, DURING THE WARRANTY PE RIOD, THE CUSTOMER USES A PART FOR THIS MA NITOWOC FOOD SERVICE EQUIPMENT OTHE R THAN AN UNMODIFIED NEW OR REC YCLED PART PURCHASED DIRECT LY FROM FRYMASTER DE AN, OR ANY OF ITS AUTHORIZED SERVIC E CENTERS, AND/OR THE PART BEING U SED IS MODIFIED FROM ITS ORI GINAL CONFIGURATION, THIS WARR ANTY WILL BE VOID. FUR[...]
-
Page 3
iii DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633. DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped wi[...]
-
Page 4
iv PROTECTOR ® SERIES GAS FRYERS TABLE OF CONTENTS CAUTIONARY STATEMENTS ........................................................................................................ i CHAPTER 1: Service Procedures 1.1 Functional Description ..................................................................................................... .1 - 1 1.2[...]
-
Page 5
v PROTECTOR ® SERIES GAS FRYERS TABLE OF CONTENTS cont. 1.15 Loading and Updating Software Procedures ................................................................... 1-38 1.16 Principal Wiring Connections ......................................................................................... 1-39 1.17 Wiring Diagrams ........................[...]
-
Page 6
THIS PAGE INTENTIONALLY LEFT BLANK[...]
-
Page 7
1-1 Inside the Ignition Module TD Out to Gas Valve To A l a r m 25 V + GND HV Ignition Wire Flame Sensor Coil PROTECTOR ® SERIES GAS FRYER CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description Protector ® series gas fryers contain a welded stainless steel frypot that is directly heated by a high efficiency infrared burner system, requiring a p[...]
-
Page 8
1-2 ignition by measuring the flow of microam ps through the flame. If the burne r does not light (or is extinguished), current to the ignition module is cut, the gas valve closes, and the ignition module “locks out” until the power switch is turned off and then back on. A probe monitors the temperature in the frypot. When the programm ed setpo[...]
-
Page 9
1-3[...]
-
Page 10
1-4 FREQUENTLY USED TEST POI NTS FOR INTERFA CE BOA RD 106-670 6 Meter Setting 12VAC Power to Controller 50VAC Scale 1 and 3 on J3 or J2 12-18 24VAC Power to Right Module 50VAC Scale 8 on J3 and GROU ND 22-28 120 VAC Pow er 250VAC Scale 11 on J3 and GROUND 110-125 120 VAC Pow er to Blowe rs 250VAC Scale 12 on J3 and GROUND 110-125 24VAC Power to Fu[...]
-
Page 11
1-5 1.6 Cleaning the Gas Valve Vent Tube 1. Set the fryer power switch and the gas valve to the OFF position. 2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease of removal. 3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to rem ove any obstruction. 4. Remove the wir[...]
-
Page 12
1-6 Pressure (m bar ) Gas Si ngle Vat Natur al Gas Lacq (G20) under 20 mbar 7 Natur al Gas Groni que * (G25) under 25 mbar 10 Natur al Gas Gronique (G25) under 20 mbar 10 Butane/ Propane (G30) at 28/ 30 or 50 mbar 17 Propane (G31) under 37 or 50 mbar 20 CE St a nda r d Bu rner Manifold Gas P ressures * Bel gian G25 = 7, 0 m bar Ga s P r e s s u r e[...]
-
Page 13
1-7 1.8 Measuring Flame Current When the burner flame is properly adju sted, it will produce a current between 2.5 μ A and 3.5 μ A. Flame current is measured by placing a microamp (not m illiamp) meter in series with the sensing wire on the ignitor. This is accomplished as follows: 1. Place the fryer power switch in the OFF position. 2. Disconnec[...]
-
Page 14
1-8 1.9.2 Replacing the Temperature Probe or High-Limit Thermostat 1. Disconnect the fryer from the electrical supply. 2. Drain cooking oil below the level of the probe or thermostat. 3. Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame. 4. Remove the top two screws in the upper corners of the computer. 5. Sw[...]
-
Page 15
1-9 1.9.4 Replacing an Ignition Module 1. Disconnect the fryer from the electrical supply. 2. Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame. 3. Remove the top two screws in the upper corners of the computer. 4. Swing the computer out from the top and allow it to rest on its hinge tabs. 5. Disconnect the w[...]
-
Page 16
1-10 1.9.6 Replacing or Cleaning a Combustion Air Blower 1. Disconnect the blower wiring harness, remove th e blower assem bly mounting nuts, and remove the blower assembly from the fryer. If cleani ng the m otor, continue with Step 2; otherwise, install the replacement blower, reconnect the wiring harness, and then go to Step 6. 2. Remove the blow[...]
-
Page 17
1-11 Blower Housing Blower W heel W rap th e motor a nd w ires with plastic wrap or a plastic bag. 4. Remove the plastic wrap from the blower m o tor assembly. Reassem ble the blower motor assembly and blower housing. Reinstall the blower shield. 5. Reinstall the blower assembly in the fryer and reconnect the wiring disconnected in Step 1. 6. Light[...]
-
Page 18
1-12 Loosen this nut and rotate shutter t o open or close air intak e. 1.9.8 Replacing a Gas Valve 1. Disconnect fryer from electrical and gas supplies. 2. Disconnect the drain safety and high-limit thermostat wires from the gas valve. Mark each wire to facilitate reconnection. 3. Remove the vent tube (on non-CE fryers) and th e enrichm ent tube fi[...]
-
Page 19
1-13 5. Remove all fittings from the old gas valve and install them on the replacement valve, using Loctite ® PST56765 or equivalent pipe thread sealant. 6. Reconnect the gas valve assembly to the fryer using Loctite ® PST56765 or equivalent pipe thread sealant, and reattach the flexible gas line(s), en richment tube(s), and the vent tube (on non[...]
-
Page 20
1-14 18. If the leak persists, use a rubber hammer and a sma ll block of wood to tap the corners of the lower combustion chamber insulation retainers. Repeat steps 15 through 17. Repeat this step until no leakage is detected. 1.9.10 Replacing the Filter Motor, Filter Pump, or Filter Pump Solenoid Valve 1. Disconnect the unit from the electrical pow[...]
-
Page 21
1-15 5. Grasp the upper edge of each computer and swi ng the computer downward. Unplug the computer wiring harness and grounding wire from the back of each computer. 6. Remove the computers by lifting them from the hinge slots in the control panel frame. 7. Disconnect the sound device wire from the interface board. 8. Disconnect the flame sensor wi[...]
-
Page 22
1-16 1.9.12 Replacing Frypot Insulation and/or Upper Burner Rails NOTE: Replacing the burner rails requires complete ly tearing down the frypot and installing new frypot insulation. Refer to the frypot exploded view below for component identification. 1. Remove the frypot per Section 1.9.11. 2. Remove the burner assemblies (1). 3. Remove insulation[...]
-
Page 23
1-17 11. Remove the upper burner rails (11). NOTE: For the following steps, re fer to the frypot exploded view on page 1-16 for component identification. 12. Remove any residual insulation, sealant, and/or oil from the exterior of the frypot. 13. Place the “L” shaped pieces of the combustion ch amber insulation (1) in the front and rear corners[...]
-
Page 24
1-18 together with two ¼” self-tapping screws. NOTE: Full-vat units have a two-piece insulation retainer and two pieces of insulation. Dual-vat units have one-piece components. 30. Return to the rear of the frypot and fully tighten all washer-nuts. 31. Remove and replace the plenum gaskets (18). 32. Place a 0.938-inch spacer (19) on the plenum-m[...]
-
Page 25
1-19 1.10 Troubleshooting and Problem Isolation Because it is not feasible to attempt to include in this m anual every conceivable problem or trouble condition that might be encountered, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipm ent, and the probable causes o[...]
-
Page 26
1-20 Occasionally, an ignition failure situation occurs in which all components appear to be serviceable and the microamp reading is within specification, but the unit nevertheless goes into ignition failure during operation. The probable cause in this case is an intermittent failure of an ignition module. When the unit is opened up for troubleshoo[...]
-
Page 27
1-21 Verify that the ignition wire is tightly connected at both ends and free of obvious signs of damage. Again, if damage is due to excessive heat in the frye r, that problem must also be corrected. Check for proper operation by disconnecting the wire from the i gnitor (spark plug), inserting the tip of a screw driver into the terminal. With the i[...]
-
Page 28
1-22 Improper temperature control problem s can be cate gorized into melt cycle problems and failure to control at setpoint problems. MELT CYCLE PROBLEMS Initiation of the melt cycle with CM7 com puters is automatic. Problems m ay originate from the computer itself, the temperature probe, or a m alfunctioning heat relay on the interface board. FAIL[...]
-
Page 29
1-23 Sediment Particle FLOW Up for reverse Down for forward PUMP • The operator attempted to filter oil that was not heated. Cold oil is thicker and causes the pump motor to work harder and overheat. If the motor hums but the pum p does not rotate, there is a blockage in the pump. Incorrectly sized or installed paper will allow food particles and[...]
-
Page 30
1-24 100/120V Modular Basket Lift Assembly P/N 106180 7SP (TYPICAL) 1.10.6 Leakage Leakage of the frypot will usually be due to improperly sealed high-lim it thermostats, RTD’s, temperature probes, and drain fittings. When inst alled or replaced, each of these components must be sealed with Loctite ® PST56765 sealant or equivalent to prevent lea[...]
-
Page 31
1-25 100-120V C onfi g urati on 208-250V C onfi g urati on BINDS AND JAMS Noisy, jerky or erratic movement of the lifts is us ually due to lack of lubrication of the rods and bushings. Apply a light coat of Lubriplate ® or similar lightweight white grease to the rod and bushings to correct the problem. Another possible cause of binding is improper[...]
-
Page 32
1-26 The wiring diagram on the Page s 1-45 and 46 identifies the components and wiring connection points. 1.11 Troubleshooting Guides The troubleshooting guides on the following pages are intended to assist service technicians in quickly isolating the probable causes of equipmen t m alfunctions by following a logical, systematic process. An additio[...]
-
Page 33
1-27[...]
-
Page 34
1-28 1.11.2 Troubleshooting the Gas Valve Prior to checking for problems associated with the ga s valve, ensure that the unit is calling for heat. Also, for non-CE units, verify that the gas valve is in the ON position. The following processes will assist you in troubl eshooting the gas valve and ruling it out as a probable cause: • If 24 VAC is [...]
-
Page 35
1-29 relay marking the wires to ease reassembly. Once replaced, reconnect the power. W hen replacing a filter relay in the transformer, ensure the 24VAC relay (8070012) is used. 1.12 Probe Resistance Chart Probe Resistance Chart For use with Protector ® Series fryers manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F OHMS C F OHMS[...]
-
Page 36
1-30 1.13.1 ATO (Automatic Top-Off) Troubleshooting Problem Probable Causes Corrective Action The yellow JIB low light won’t illuminate. A. Power not present in the transformer box. B. Failed transformer. C. Loose wire connection A. Ensure power is present in the transformer box. B. If power is present in transformer box, check the transformer fo[...]
-
Page 37
1-31 1.13.2 ATO (Automatic Top-Off) Board Pin Positions and Harnesses Connector From/To Harness # Pin # Function Voltage Wire Color 1 Output DV - Vat #1 Green 2 Output FV - Vat #1 Red 3 Output DV - Vat #2 Green 4 Output FV - Vat #2 Red 5 Output DV - Vat #3 Green Solenoids 8074718 (FV) 8074717 (DV) 6 Output FV - Vat #3 Ground Red Top Off Pump 7 Top [...]
-
Page 38
1-32 1.13.3 Replacing the ATO Board or Transformer Disconnect the fryer from the electrical power supply. Locate the ATO box (see Figure 1 on page 1-29), behind the JIB (Jug In Box). Remove the cover to expose the transformer and ATO board (see Figure 2). Mark and unplug any wires or harnesses. Replace the defective component and reattach all wires[...]
-
Page 39
1-33 Problem Probable Causes Corrective Action E. Power supply component or interface board has failed. E. If any component in the power supply system (including the transformer and interface board) fail, power will not be supplied to the computer and it will not function. Computer locks up. Computer error. Remove and restore power to the computer.[...]
-
Page 40
1-34 Problem Probable Causes Corrective Action CM7 display shows PROBE FAILURE. Problem with the temperature measuring circuitry including the probe. This indicates a problem within the temperature measuring circuitry. Check resistance of probe, if faulty replace probe. CM7 display shows PROBE FAILURE with alarm sounding. Damaged computer wiring ha[...]
-
Page 41
1-35 Problem Probable Causes Corrective Action CM7 display shows software for only CM7. Loose or damaged harness Check that all harnesses between CM7’s and ATO are secure. Check for loose pins. If the problem persists, swap out computer from one bank to another and reinitialize. 1.14.2 CM7 Useful Codes To enter any of the following codes: Press t[...]
-
Page 42
1-36 1.14.3 CM7 Menu Summary Tree Reflected below are th e major programming sections in the CM7 an d the order in wh ich submenu heading s will be found under the sections in the Install ation and Operation Manual . Adding New Menu Items See section 4.10.2 Storing Menu Items in Product Buttons See section 4.10.3 Temperature Conversion from F ° to[...]
-
Page 43
1-37 1.14.4 CM7 Board Pin Positions and Harnesses Connector From/To Harness PN Pin # Function Voltage Wire Color 1 12VAC In 12VAC 2 Ground 3 12VAC In 12VAC 4 FV Heat Demand 5 V Relay 12VDC 6 DV Heat Demand 7 R/H B/L 12VDC 8 Analog Ground 9 L/H B/L 12VDC 10 ALARM 11 Sound Device 5VDC 12 ALARM 13 FV Probe 14 Common Probes 15 DV Probe Black 16 17 18 1[...]
-
Page 44
1-38 1.15 Loading and Updating Software Procedures Loading Software from an SD card to an CM7 Computer and ATO Board To update CM7 and ATO software follow these steps: 1. Switch all computers to OFF . Press the TEMP button to check current CM7/ATO software version. 2. Remove the two screws on the left side cover plate of the CM7 computer. 3. With t[...]
-
Page 45
1-39 1.16 Principal Wiring Connections[...]
-
Page 46
1-40 1.17 Wiring Diagrams 1.17.1 Main The Heat Strip is not present here on 330’s. Refer to "PRINCIPAL WIRING CONNECTIONS" on Page 1-39 for detail of connection points J1, J2, J3.[...]
-
Page 47
1-41 1.17.2 Transformer / Filter Boxes 1.17.2.1 FPGL230 and 430 Transformer / Filter Box (Domestic)[...]
-
Page 48
1-42 1.17.2.2 FPGL330 Transformer / Filter Box (Domestic)[...]
-
Page 49
1-43 1.17.3 Modular Basket Lift (100/120V)[...]
-
Page 50
1-44 1.17.4 Modular Basket Lift (208/250V)[...]
-
Page 51
1-45 1.18 Simplified Wiring Diagrams 1.18.1 FPGL30 Series Full Vat K 3 H E A T R E L A Y A I R O P T I O N A L A I R S W I T C H B L O W E R H I G H L I M I T 1 2 V 2 4 V T E M P P R O B E 2 4 V L E D 3 L E D 5 R - G V R - H E A T L E D 4 R P W R V 1 D A L A R M L E D 6 1 2 V L H E A T L E D 2 L P W R V 2 S P O W E R O N / O F F T R O U B L E H E A[...]
-
Page 52
1-46 1.18.2 FPGL30 Series Full Vat (Australia and Pacific Rim ) K3 HEAT RELAY OPTIONAL AIR SWITCH BLOWER 12V 24V TEMP PROBE 24V LED 3 LED 5 R-GV R- HEAT LED 4 R PWR V1S ALARM LED 6 12V L HEAT LED 2 L PWR ALARM V2S ON/ OFF TROUBLE HEAT T J3 6 2 12 9 11 8 5 4 3 1 J2 11 11 4 4 13 13 14 14 10 10 5 5 3 3 1 1 2 2 RIGHT IGNITION MODULE ALAR M TD VALVE GND[...]
-
Page 53
1-47 1.18.3 FPGL30 Series Simplified Wiring[...]
-
Page 54
1-48 1.18.4 FPGL30 Series Data Network Flow chart[...]
-
Page 55
2-1 PROTECTOR ® SERIES GAS FRYERS CHAPTER 2: PARTS LIST 2.1 Accessories ITEM PART # COMPONENT 1 803-0209 Brush, Frypot 2 803-0197 Cleanout Rod, 27-inch 3 810-2793 Hanger, Basket 4 809-0171 Thumbscrew, ¼-20 X 1 ⅜ -inch Universal Hood (use 809-0921 for Spacer) 5 106-8930 Cover, Frypot, Full Vat * 826-0993SP Handle Kit, Frypot Cover (includes hand[...]
-
Page 56
2-2 2.2 Basket Lift Assembly and Associated Parts[...]
-
Page 57
2-3 2.2 Basket Lift Assembly and Associated Parts cont. ITEM PART # COMPONENT 1 200-2942 Mount, Modular Basket Lift 2 806-5964SP Motor Assem bly, Modular Basket Lift 3 807-2133 Capacitor, 12.5 μ Farad, 250VAC Motor Run 4 807-2572 Microswitch 5 Resistor Assembly 806-8530SP 100-120V Modular Basket Lift (see Note 2 in illustration) 106-2771 208-250V [...]
-
Page 58
2-4 2.3 Doors, Sides, Flue Caps, Top Caps and Casters 5 4 6 1 2 3 7 8 9 10 ITEM PART # COMPONENT 1 211-6510 Side, Standard Cabinet Left SS (use 221-0323 for Enameled Steel) 2 212-6510 Side, Standard Cabinet Right SS (use 222-0323 for Enameled Steel) 3 810-1105 Magnet, Door (vertical) (use 810-2346 for horizontal over filter pan) 4 106-4397 Door, Le[...]
-
Page 59
2-5 2.4 Drain System Components 2.4.1 Drain Valves and Associated Parts ITEM PART # COMPONENT 1 809-0540 Nut, ½-13 2-Way Hex Lock 2 900-2936 Retainer, Nut Drain Valve 3 810-3350 Handle, Drain Valve FV 4 810-0677 Grip, Drain Handle 5 901-2348 Cover, Safety Switch 6 807-2103 Switch, Micro 7 816-0220 Insulation, RF Switch 8 806-8137 Bracket, Switch D[...]
-
Page 60
2-6 2.4.2 Drain Tube Sections and Associated Parts ITEM PART # COMPONENT 1 823-6610 4625 Drain Tube, Full-Vat Left Closed/Right End Open 2 823-6467 Drain Tube, Dump GL30 3 823-6615 Drain Tube, Dump GL230 4 823-6611 Drain Tube, Full-Vat Right, Left, Open/Right End Open 5 823-6612 Drain Tube, Full-Vat Center, Left Open/Right End Open 6 823-6614 Drain[...]
-
Page 61
2-7 2.5 Electronics and El ectrical Components 2.5.1 Component Boxes[...]
-
Page 62
2-8 2.5.1 Component Boxes cont. ITEM PART # COMPONENT 1 810-1164 Block, One-Piece Screwless Term inal 2 816-0217 Insulation, Term inal Block Paper 3 807-3843 Fuse 3A 250V Domestic 807-3293 Fuse 5A 125V International Only 4 807-3483 Cable, 21-inch Ignition – For 807-3366/3365 Modules * 826-2024 Cable, Ignition - 1 wire / 1 Rajah * 826-1721 Cable, [...]
-
Page 63
2-9 2.5.2 Transformer Boxes[...]
-
Page 64
2-10 2.5.2 Transformer Boxes cont. ITEM PART # COMPONENT Box Assembly, Transform er A 106-9021SP FPGL230 B 106-9022 FPGL330 C 106-9734 GL230 CE Export D 106-9710 GL330 CE Export E 106-5801 GL430/252 1 106-8133 Cable Assembly, Transform e r Box Line GL230,330, 330 CE Export 2 106-8168 Cable Assembly, Transform er Box Line GL230 CE Export 3 106-8170 [...]
-
Page 65
2-11 2.5.3 Computers and Associated Components NOTE: See Page 2-7 for Interface Board to Computer Wiring Harness. ITEM PART # COMPONENT Replacement CM7 Computer 108-0231 Non-CE CM7 (For use in US, Canada, Mexico and all other non-CE coun- tries) * 810-3141 Sound Device, Universal SMT * Not illustrated.[...]
-
Page 66
2-12 2.6 Wiring 2.6.1 Main Wiring Harnesses 2-PIN FEMALE CONNECTOR 12-PIN MALE CONNECTOR 12-PIN MALE CONNECTOR 9-PIN M ALE CONNECTOR 6-PIN MALE CONNECTOR 12-PIN MALE CONNECTOR 12-PIN MALE CONNECTOR 2-PIN FEMALE CONNECTOR 807-1978 807-4014 ITEM PART # COMPONENT 807-1978 U.S. and Non-CE Export Main Wiring Harness 50/52 807-4014 U.S. and Non-CE Export[...]
-
Page 67
2-13 2.6.2 CM7 and ATO Wiring Harnesses (Refer to wiring diagram on page 1-49.) ITEM PART # COMPONENT * 807-4546 Computer Communication (used from Computer to Computer) * 807-4655 FV Harness RTD Medium (used from RTD to ATO Board) * 807-4654 FV ATO/RTD Probe * 807-4553 ATO Power (used from Transformer to ATO Board) * 807-4719 ATO Pump and JIB (used[...]
-
Page 68
2-14 2.7 Frypots and Associated Components 2.7.1 Full-Vat Frypot Components NOTE: All insulation and gaskets can be ordered in a single kit, P/N 826-2595. Kit 826-2592 contains the insulation and gaskets re- quired when replacing burners.[...]
-
Page 69
2-15 2.7.1 Full-Vat Frypot Components cont. ITEM PART # COMPONENT 106-8978SP Frypot Assembly Full-Vat Protector ® HE (NAT) 106-8979 Fry pot Assembly Full-Vat Protector ® HE (PRO) 826-2595 Insulation Kit, Complete Full-Vat 826-2592 Insulation Kit, Burner Full-Vat 1 106-7524 Flue Assembly, Full-Vat 2 220-2222 Back, Lower Full-Vat Combustion Chamber[...]
-
Page 70
2-16 2.7.2 Frypot Assemblies and Associated Parts 1 2 3 4 5 ITEM PART # COMPONENT 1 106-8978SP Frypot Assem bly, F u l l - V a t P r o t e c to r N a t u r a l 106-8979SP Frypot Assembly, F u l l - V a t P r o t e c t o r L P 2 106-9025SP Valve, Drain Assy . FV 3 826-2569 Probe, RTD and Fitting Kit 4 807-0678 Temperature Probe * 210-0681 Probe Guar[...]
-
Page 71
2-17 2.8 Gas Supply and Combustion Sy stem Components FPGL30 Full Vat Gas Manifold (Typical) The example ill ustrated is typical of FPGL30 Protector ® Series Fryer Gas Manifold s. Each manifo ld is assembled from standard 1 /2-, 3/4-, and 1-inch NPT black iro n pipe nipples, elbo ws, tees, plugs, an d unions, which ma y be locally acquired. 2 3 4 [...]
-
Page 72
2-18 2.8 Gas Supply and Combusti on System Components cont. ITEM PART # COMPONENT 1 Ignitor (includes gasket 816-0059, which may be ordered separately) 826-0981 Natural Gas (G20, G25) 826-0982 Propane (G30, G31) 826-1002 Manufactured Gas 2 Blower Assembly, Combustion Air (includes harness and Item s 4, and 5) 106-2996SP 100V 50/60 Hz (Left) 106-299[...]
-
Page 73
2-19 2.9 Gas Valves and Associated Components[...]
-
Page 74
2-20 2.9 Gas Valves and Associated Components cont. ITEM PART # COMPONENT 1 Valve, Non-CE Gas 826-1122 Natural Gas (G20, G25) 826-1120 Kit Natural Gas w/ flexlines and hardware 826-1123 Propane Gas (G30, G31) 826-1121 Kit, Propane Gas w/ flexlines and hardware 2 810-1715 Valve, CE Gas (G20, G25, G30, G31) 3 810-1041 Accessory Kit (contains parts to[...]
-
Page 75
2-21 2.10 Filtration System Components 5 4 3 2 1 6 10 12 13 14 15 16 8 18 17 7 17 10 11 19 15 20 9[...]
-
Page 76
2-22 2.10 Filtration System Components cont. ITEM PART # COMPONENT 1 823-6616 Lid, Multi-Vat Fryers, Standard Size Filter Pan 823-6333 Lid, Two-Vat Fry er, Half Size Filter Pan 2 810-2874 Crumb Tray, Standard Size Filter Pan 3, 4 and 5 Vat 810-3288 Crumb Tray, Two-Vat Fry er, Half Size Filter Pan 3 810-2091 Hold-Down Ring 13.65 x 21.41, St andard S[...]
-
Page 77
2-23 2.11 Return Valve Assembly and Associated Parts ITEM PART # COMPONENT 106-8018 Valve, Return Assy . FV 1 810-2201 Valve, Return ½” Ball 2 902-2772 Handle, Right Valve 3 813-0165 Elbow, Street ½” x ½” NPT 90 ° BM 4 813-0087 Nipple, ½” x 1.50” NPT 5 813-0062 Elbow, 90° ½” BM 6 813-0265 Nipple, ½” x 2.50 NPT BM 7 824-1601 Co[...]
-
Page 78
2-24 2.12 ATO (Auto Top-Off) Components 2.12.1 JIB (Jug In Box) Low Indicator Light Assembly ITEM PART # COMPONENT 1 106-8105SP Light, Yellow 24VDC LED Flush 2 230-4142 Bracket, Protector Light 2.12.2 ATO (Automatic Top-Off) Board ITEM PART # COMPONENT 1 106-9258 Box, Assembly Auto Top Off 2 Board RTD 2 816-0771 Seal, Top Off Board 3 106-9611 PCB B[...]
-
Page 79
2-25 2.12.3 ATO (Automatic Top-Off) Solenoid and Pump Assemblies 6 1 2 3 4 5 7 9 8 ITEM PART # COMPONENT 1 106-9680SP Pump, ¼ FNPT 12VDC, 19PSI 15.1GPH 2 106-8477 Solenoid Manifold Assembly GL30-3 (includes three solenoid assemblies) 3 106-8014 Solenoid Manifold Assembly GL30-6 (includes six solenoid assemblies) 4 807-4590 Solenoid 5 813-0940 Elbo[...]
-
Page 80
2-26 2.13 Wiring Connectors, Pin Terminals and Tools ITEM PART # COMPONENT 1 807-1068 2-Pin Female 2 807-0158 6-Pin Female 3 807-0156 9-Pin Female 5 807-0159 12-Pin Female 5 807-0875 15-Pin Female 6 807-1067 2-Pin Male 7 807-0157 6-Pin Male 8 807-0155 9-Pin Male 9 807-0160 12-Pin Male 10 807-0804 15-Pin Male 11 826-1341 Terminal, Female Split Pin ([...]
-
Page 81
2-27 2.14 Fasteners ITEM PART # COMPONENT * 809-0429 Bolt, ¼-inch – 20 x 2.00-inch Hex Head ZP Tap * 809-0131 Bolt, ¼-inch -20 x ¾-inch Hex * 809-0953 Bolt, ¼-20 x ¾-inch Hex Head * 807-1926 Bushing, .875-inch Split * 809-0514 Capscrew, 5/16-inch-18 NC Hex * 809-0448 Clip, Tinnerman * 826-1351 Nut Retainer, ¼-20 (Pkg. of 10 – for basket h[...]
-
Page 82
2-28 2.14 Fasteners cont. ITEM PART # COMPONENT * 809-0500 Screw, 10 x ½-inch Hex Washer Head 410 SS * 809-0434 Screw, 10 x ⅜ -inch Hex Washer Head NP * 809-0123 Screw, 10 x ¾-inch Slot Head * 826-1389 Screw, ¼-20 x ¾-inch Hex Head ZP (Pkg. of 10) (809-0131) * 826-1346 Spacer, Ignition Module (Pkg. of 10) * 810-2763 Spacer, Interface Board * [...]
-
Page 83
THIS PAGE INTENTIONALLY LEFT BLANK[...]
-
Page 84
Frymaster, L.L.C., 8700 Line Av enue, Shrev eport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318- 219-7140 FAX (Tech Support) 1-318-219-7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 819-6345 FEBRUARY 2009[...]