Go to page of
Similar user manuals
-
Fryer
Frymaster BIH14
27 pages 12.11 mb -
Fryer
Frymaster RE14-2
2 pages 0.51 mb -
Fryer
Frymaster 45
76 pages 3.85 mb -
Fryer
Frymaster 824E
30 pages 1.45 mb -
Fryer
Frymaster FPEL414
2 pages 0.61 mb -
Fryer
Frymaster BK1814E
36 pages 0.67 mb -
Fryer
Frymaster Under Fryer Filter (UFF)
54 pages 3.53 mb -
Fryer
Frymaster M2000
26 pages 3.42 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Frymaster FOOTPRINT H50, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Frymaster FOOTPRINT H50 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Frymaster FOOTPRINT H50. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Frymaster FOOTPRINT H50 should contain:
- informations concerning technical data of Frymaster FOOTPRINT H50
- name of the manufacturer and a year of construction of the Frymaster FOOTPRINT H50 item
- rules of operation, control and maintenance of the Frymaster FOOTPRINT H50 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Frymaster FOOTPRINT H50 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Frymaster FOOTPRINT H50, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Frymaster service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Frymaster FOOTPRINT H50.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Frymaster FOOTPRINT H50 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Frymaster, a member of the Co mmercial Food Equipm ent Serv ice Association, recommends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 JUNE 2009 www.frymaster.com Email: service@frymaster.com *8196083* Pro H50/55-Series Gas Fryers Service and Parts Manual[...]
-
Page 2
NOTICE IF, DURING THE WARRANTY PERIOD, THE CUST OMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER TH AN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTH ORIZED SERVICE CENTERS, AND/OR THE PART BEIN G USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THI S WARRANTY WILL BE VOID. FURTHER, FRYMAST ER DEAN AN[...]
-
Page 3
DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633. DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with l[...]
-
Page 4
PRO H50/55-SERIES GAS FRYERS TABLE OF CONTENTS i CHAPTER 1: Service Procedures 1.1 Functional Description ..................................................................................................... ............................. 1-1 1.1.1 The Electroni c Ignition System ......................................................................[...]
-
Page 5
PRO H50/55-SERIES GAS FRYERS TABLE OF CONTENTS ii 1.11.6.4 FPPH350/355 Transformer/ Filter Box .................................................................................. .....1-48 1.11.7 Modular Bask et Lift (1 00/120V) ........................................................................................ ........1-49 1.11.8 Modular Ba sk[...]
-
Page 6
1-1 Inside the Ignition Module TD Out to Gas Valve To A l a r m 25 V + GND HV Ignition Wire Flame Sensor Coil PRO H50/55-SERIES GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 Functional Description Pro (H50/55) Series gas fryers cont ain a welded stainless steel frypot that is directly heated by a high efficiency infrared burner system requiring a pp[...]
-
Page 7
1-2 valve via a normally closed high-limit switch (and, in fryers with built-in filtration system s, a normally closed drain safety switch). Simultaneous ly, the m odule causes the ignitor to spark for 4 seconds to light the burner. A flame sensor verifies the burner ignition by measuring the flow of microamps through the flam e. If the burner does[...]
-
Page 8
1-3 CURRENT FLOW THROUGH INTERFACE BOARD 106-0386 (PRO SERIES APPLICATION) 1 2 3 4 5 6 7 8 9 10 11 12 J3 J2 PIN 1 J2 1 2 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 J1 LEFT-VAT FULL- OR RI GHT- VAT INTERFACE BOARD 12 VAC TO CPTR J3 PIN 1 GROUND GROUND 3 COMPUTER (1 2 VAC) J3 PIN 3 COMPUTER RT HT RELAY COMPUTER LT HT REL AY COMPUTER RT [...]
-
Page 9
1-4 FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD 106-0386 TEST METER SETTING PINS RESULTS 12VAC Power to Controller 50VAC Scale 1 and 3 on J3 or J2 12-18 24VAC Power to Right Module 50VAC Scale 8 on J3 and GROUND 22-28 120 VAC Power 250VAC Scale 11 on J3 and GROUND 110-125 120 VAC Power to Blow ers 250VAC Scale 12 on J3 and GROUND 110-125 24VAC [...]
-
Page 10
1-5 3. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords. 1.3 Cleaning the Gas Valve Vent Tube 1. Set the fryer power switch and the gas valve to the OFF position. 2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease of[...]
-
Page 11
1-6 4. On non-CE fryers only , place the gas valve in the ON position. 5. Place the fryer power switch in the ON position. Wh en the burner has lit and burned steadily for at least one minute, compare the gas pressure r eading to the pressure for the corresponding gas in the appropriate table below. The tables list the burner manifold gas pressures[...]
-
Page 12
1-7 7. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove the fitting from the pressure tap hole and reinstall the pressure tap plug. 1.5 Measuring Flame Current When the burner flame is properly adjusted, it will produce a current between 2.5 μ A and 3.5 μ A. Flame current is measured by placing a micro[...]
-
Page 13
1-8 1.6.2 Replacing the Temperature Probe or High-Limit Thermostat 1. Disconnect the fryer from the electrical supply. 2. Drain cooking oil below the level of the probe or thermostat. 3. Lift up on the bezel to disengage the tabs on its lower edge from the control panel frame. Slide the bezel down to disengage the upper tabs. Remove the top two scr[...]
-
Page 14
1-9 b. If replacing the high-limit thermostat, use a pin pusher to disconnect the lead running to the connector and insert the corresponding lead from the new thermostat. Disconnect the other lead from the drain safety switch and connect the remaining lead from the new thermostat. 17. Reverse steps 1-12 to reassemble the fryer. 1.6.3 Replacing the [...]
-
Page 15
1-10 1.6.5 Replacing an Ignitor Assembly DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect the fryer from the electrical supply. 2. Disconnect the flame sensor wire by carefully pulling its push-on terminal f rom the terminal strip on the ignitor. Disconnect the gas enrich ment tube at the ig[...]
-
Page 16
1-11 2. Remove the blower motor shield and separate the blower motor from the housing as shown in the illustration on the following page. Remov e these screw s to remove the sh ield fro m the blower assembly. Remove these nuts to separate the blower motor from the housing. 3. Wrap the motor with plastic wrap to prevent water f rom entering it. Spra[...]
-
Page 17
1-12 6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.2 of the Pro H55-Series Gas Fryer Installation and Operation Manual (P/N 819-5991). 7. After the burners have been lit for at least 90 seconds, observe the flames through the burner sight glasses located on each side of the combustion air blower. The air/gas [...]
-
Page 18
1-13 1.6.7 Replacing a Gas Valve DANGER Drain the frypot or remove the handle from the drain valve before proceeding further. 1. Disconnect the fryer from the electrical and gas supplies. 2. Disconnect the drain safety and high-limit thermostat wires from the gas valve. Mark each wire to facilitate reconnection. 3. Remove the vent tube (on non-CE f[...]
-
Page 19
1-14 ALL OTHER VALVES 4. Carefully unscrew the valve from the manifold. NOTE: Som e models may have the valve attached to the manifold by means of a pipe union. In such cases, remove the valve by uncoupling the union. 5. Remove all fittings from the old gas valve and install them on the replacement valve, using Loctite ® PST56765 or equivalent pip[...]
-
Page 20
1-15 8. Remove the washers and tubular spacers from th e m ounting studs, then pull the inner covers straight out toward you until clear of the mounting studs. 9. Grasp the burner firmly and pull it toward you un til it clears the burner channels, taking care not to damage the ceramic tiles in the process. 10. Clean all debris from the burner chann[...]
-
Page 21
1-16 3. Position a container beneath the oil return fitti ng at the front of the cabinet. Disconnect the flexible oil line from the fitting, allowing any residual oil to drain into the container. 4. At the rear of the fryer, unplug the left connector (as viewed from the rear of the fryer) from the transformer box. Using a pin pusher, push the pump [...]
-
Page 22
1-17 DANGER DO NOT attempt to drain more than one full fry pot or two split frypots into the SDU at one time. 3. Dismount the topcap by removing the screws on the bottom of each front corner and lifting the topcap straight up. 4. Remove the bezels by lifting them up to disengage the tabs along the lower edges from the slots in the control panel fra[...]
-
Page 23
1-18 20. Remove the drain valve(s), temp erature probe(s), high-limit thermostat(s), and ignitor assemblies. Inspect each of these components carefully and install them in the replacement frypot if they are in serviceable condition. Use Loctite ® PST56765 sealant or equivalent on component threads. NOTE: Some servicers, based upon their experience[...]
-
Page 24
1-19 Disassembling A Frypot (Full-vat Illustrated) Spacers Spacer 10 2 3 4 5 6 7 8 1 11 9[...]
-
Page 25
1-20 To re-assemble with new insulation and/or upp er burner rails (use illustration on page 1-23): 13. Place the “L” shaped pieces of com bustion cham ber insulation (1) in the front and rear corners of both upper rail-retaining slots. 14. Use a small amount of furnace or m uffler repair cement to seal the gaps at each end of both lower rails.[...]
-
Page 26
1-21 25. Insert the upper front insulation (10) into its re tainer (11), making sure that the holes in each piece are aligned with one another. Install the assembly with the insulation side toward the frypot and secure with ¼”-20 washer-nuts. Do not over tighten. 26. Place a washer on each of the four lower studs on th e front of the frypot. Ins[...]
-
Page 27
1-22 Re- assem bling A Fryp ot (Full-vat Illu stra ted) 6 5 4 1 2 7 8 9 1 3 10 11 12 13 14 18 20 19 17 16 15 24 23 21 22[...]
-
Page 28
1-23 1.7 Troubleshooting and Problem Isolation Because it is not feasible to attempt to include in this m anual every conceivable problem or trouble condition that might be encountered, this section is intended to provide technicians with a general knowledge of the broad problem categories associated with this equipment, and the probable causes of [...]
-
Page 29
1-24 valve handle appears to be in the closed position, the microswitch is still open). If the valve is fully closed, refer to the troubleshooting guide, TROUBLESHOOTING THE 24 VAC CIRCUIT . Some typical causes of ignition failure in this cate gory include a defective sensing wire in the ignitor assembly, a defective module, a defective ignition wi[...]
-
Page 30
1-25 If the fryer’s gas and air supplies are okay, the probl em is mo st likely with one of the electrical components. Examine the ignition m odule and c ontroller for signs of melting, distortion, and/or discoloration due to excessive heat build-up in the fryer (this condition usually indicates improper flue performance). A melted or distorted i[...]
-
Page 31
1-26 If these causes are ruled out, the probable cause is a misadjusted gas valve regulator. Refer to Section 1.4, Checking the Burner Manifold Gas Pressure , for the gas valve adjustment procedure. 1.7.3 Improper Temperature Control Temperature control, including the melt cycle, is a function of several interrelated components, each of which must [...]
-
Page 32
1-27 COMMON COMPUTER COMPLAINTS Most problems concerning computers have to do with program ming them. There are four com mon complaints: 1. Fryer constantly displays “ HI .” Cause: Setpoint is incorrect or missing. Corrective Action: Press 1650, enter the correct setpoint using keypad, then press to lock in the setpoint. 2. Temperature is displ[...]
-
Page 33
1-28 Sediment Particle FLOW Up for reverse Down for forward PUMP • Shortening that remained in the pan after prev ious f iltering solidified in the suction tube recess in the bottom of the pan or the suction tube. Adding hot oil to the pan and waiting a few minutes will usually correct this problem. A f lexible wire can be used to clean out the s[...]
-
Page 34
1-29 M P u m p R ela y C o il Micro-swi tches Pump Motor Swit ch Pu m p M o to r S ole n oid s 24 VAC FootPrint Pro Schem atic Pum p Heater Tape Verifying Solenoid Operation Proper operation of the 24 VAC manifold and pump solenoids can be verified by removing the pump motor lead from terminal 4 of the pump motor relay in the filter wiring box and [...]
-
Page 35
1-30 100/120V Modular Basket Lift Assembly P/N 106180 7SP (TYPICAL) the frypot until the rod loses contact with the upper microswitch, cutting power to the motor and again reversing the direction of current flow. Problems with the basket lift can be grouped into three categories: • Binds and jams • Motors and gears • Electronics. BINDS AND JA[...]
-
Page 36
1-31 1.7.8 Interpretation of Analog Controller Lights Power light on, heat light cycling, trouble light off, and melt light on: • If fryer oil temperature is below 180ºF (82º C), the lights indicate the unit is operating normally. • If the oil temperature is above 180ºF (82ºC) and the heat light continues to cycle as if in the melt cycle, t[...]
-
Page 37
1-32 The following processes will assist you in troubles hooting the 24 VAC circuit and ruling it out as a probable cause: • 24 VAC is not present on the interface board J3 pin 9 (LED 5 (GV)) and, on dual units, on J1 pin 9 (LED 1 (GV)). 1. If LED 3 is not continually lit, the probable causes are a failed 24 VAC transformer or failed wiring betwe[...]
-
Page 38
1-33 24 VOLT CIRCUIT With Interface Board 106-0386 and One 807-3366 (FV) Ignition Module NOTE: Som e u ni ts m a y be wi red in this manner. IGNITION MODULE V1S PWR (left side) V2S LED 5 (GV) J3 PIN 9 Jumper LED 3 (24V) 24V TRANSFORMER IGNITION MODULE PWR (right side) V1D LED 5 (GV) J3 PIN 9 J3 PIN 8 LED 4 (PWR) HIGH LIMIT SWITCH GAS VALVE High Vol[...]
-
Page 39
1-34 LEFT VAT IGNITION MODULE LED 2 (PWR) PWR V2D HIGH LIMIT SWITCH LED 1 (GV) GAS VALVE IGNITION MODULE PWR V1D HIGH LIMIT SWITCH GAS VALVE 24V TRANSFORMER LED 5 (GV) J1 PIN 9 J3 PIN 9 RIGHT VAT J3 PIN 8 24 VOLT CIRCUIT With Interface Board 106-03 86 and Two 807-3365 (DV) Ignition Modules LED 4 (PWR) High Voltage to Ignitor High Voltage to Ignitor[...]
-
Page 40
1-35 1.8.2 Troubleshooting the Gas Valve Prior to checking for problems associated with the ga s valve, ensure that the unit is calling for heat. Also, for non-CE units, verify that the gas valve is in the ON position. The following processes will assist you in troubl eshooting the gas valve and ruling it out as a probable cause: • If 24 VAC is n[...]
-
Page 41
1-36 1. If resistance is not 5 mega-Ohms or greater between each pin and chassis ground, the probe has failed and must be replaced. 2. If resistance is 5 mega-Ohms or greater between each pin and chassis ground, the probe is okay. 1.8.4 Probe Resistance Charts Probe Resistance Chart For use with Pro Series fryers manufac tured with Minco Thermistor[...]
-
Page 42
1-37 1.9. Simplified Wiring Diagrams 1.9.1 Wiring Diagram for Full-Vat Dual-Spark Module AIR SWITCH ONLY ON CE AND SOME EXPORT UNITS LINE VOLTAGE K3 HEAT & BLOWER RELAY AIR OPTIONAL AIR SWITCH BLOWER 12 V 24V TEMP PROBE 24V LED 3 LED 5 R-GV R HEAT LED 4 R PWR V1D ALARM LED 6 12 V L HEAT LED 2 L PWR ALARM V2 S POWER ON/OFF TROUBLE HEAT T J3 6 2 [...]
-
Page 43
1-38 1.9.2 Wiring Diagram for Full-Vat Single-Sp ark Module (Austrailia and Pacific Rim) K3 HEAT & BLOWER RELAY AIR OPTIONAL AIR SWITCH BLOWER HI LIMIT 12 V 24V TEMP PROBE 24V LED 3 LED 5 R-GV R HEAT LED 4 R PWR V1S ALARM LED 6 12 V L HEAT LED 2 L PWR ALARM V2 S POWER ON/OFF TROUBLE HEAT T J3 6 2 1 2 9 1 1 8 5 4 3 1 J2 1 1 1 1 4 4 1 3 1 3 1 4 1[...]
-
Page 44
1-39 1.9.3 Wiring Diagram for Dual-Vat Single-Spark Module TD GND ALARM 25V+ RIGHT IGNIT OR VALVE TEMP PROBE BLOWER 24 V OPTIONAL AIR SWITCH 6 J3 1 1 4 8 4 8 9 9 R-HEAT LED 4 K2 HEAT RELAY R-GV LED 5 R PWR V1 D ALARM 35 1 04 1 3 1 4 1 1J 2 35 1 04 1 3 1 4 1 1 TROU BLE POWER HEAT BNR GND AIR 24 V LED 3 RIGHT IGNITION MODULE TD BNR GND GND ALARM 25V+[...]
-
Page 45
1-40 1.10 Principal Wiring Connections GROUND LINE VOLTAGE L1 GROUND, JUMPE RE D FROM PIN 2 GROUND, JUMPE RE D TO P IN 11 JUMPERED FROM PIN 4 JUMPERED TO PIN 7 JUMPERED TO PIN 6 JUMPERED FROM PIN 12 FROM T1, J UMPERED T O PIN 8 FROM J1 PIN 10 FROM J3 PIN 7 FROM J3 PIN 10 FROM J1 PIN 7 FROM T2, J UMPERED TO PINS 3 & 9 LINE VOLTAGE COM TO FI L TE[...]
-
Page 46
1-41 1.11 Wiring Diagrams 1.11.1 Pro H50/55-Series Fryer, Multi-vat 8051315C Refer to "PRI NCIPAL WI RING C ONNECTI ONS" on Page 1-41 for detail of connection points J1, J2, J3, C2, C 3, and C5. K1 2 COMPUTER GROUND DETAIL A A SENSE 2 ALARM(GND) VALVE(GND) 24VAC(GND) 24VAC SPARK 2 SPARK 1 GND (BURNER) VALVE ALARM SENSE 1 SOUND DEVICE SOUN[...]
-
Page 47
1-42 1.11.2 Pro H50/55-Series Fr yer, Single, Full-vat 805-1675[...]
-
Page 48
1-43 1.11.3 Pro H50/55-Series Fr yer, Single, Dual-vat[...]
-
Page 49
1-44 1.11.4 Pro H50/55-Series Fryer, Single, CE[...]
-
Page 50
1-45 1.11.5 Pro H50/55-Series Fr yer, Single, FAST-ready[...]
-
Page 51
1-46 1.11.6 Transformer/Filter Boxes 1.11.6.2 FPH150/155 Transformer/Filter Box EXTRACTE D FROM 8051377B 1.11.6.1 MPH150/155 Transformer/Filter Box[...]
-
Page 52
1-47 1.11.6.3 FPPH 250/255/450/455 Tr ansformer/Filter Box 8051340C[...]
-
Page 53
1-48 1.11.6.4 FPPH 350/355 Transformer/Filter Box[...]
-
Page 54
1-49 1.11.7 Modular Basket Lift (100/120V) 1 2 43 5 6 12 - - - - - 7 8050518E[...]
-
Page 55
1-50 1.11.8 Modular Basket Lift (208/250V) 8 9 10 11 12 7 BLACK GREEN WHITE RED ORANGE BLUE mF 12.5 NC NO M M F m 12.5 NO NC NC NO 1 2 3 4 NO NC 5 6 REFERENCES TO LEFT & RIGHT ARE FROM THE RE AR OF THE FR YER 8050946B LOWER SWITCH LOWER SWITCH UPPER SWITCH UPPER SWITCH (NOT USED ON 208/220V) BRN 1 RED 1 BRN 2 RED 2 101C 93C BLK BLK 25ohm 25ohm [...]
-
Page 56
1-51 1.11.9 Wiring Diagrams – Oil Return/Disposal Oil Return/Wand Wiring (Japan) Oil Return/Disposal Wiring (Sonic)[...]
-
Page 57
2-1 PRO H50/55-SERIES GAS FRYERS CHAPTER 2: PARTS LIST 2.1 Accessories 2 3 4 9 10 11 12 13 5 15 14 6 7 1 8 ITEM PART # COMPONENT 1 803-0271 Basket, Twin 2 803-0099 Basket, Full (cannot be used with basket lifts) 3 803-0133 Basket Support Rack, Dual Vat 4 803-0132 Basket Support Rack, Full Vat * 803-0136 Basket Support Screen, Full Vat (screen w/han[...]
-
Page 58
2-2 2.2 Basket Lift Assemblies and Component Parts NOTES: 1. Assemblies 106-1807SP (100-120V) and 106-1810SP (208-250V) do not include Items 8, 16, or 24-33. These items must be ordered separately. 2. For 100-120V units, each individual resistor (807- 2661) may be replaced or the entire reis tor assembly (806-8530SP) may be replaced. 3. Fo r 208-25[...]
-
Page 59
2-3 ITEM PART # COMPONENT 1 200-2942 Mount, Modular Basket Lift 2 806-5964SP Motor Assembly, Modular Basket Lift 3 807-2133 Capacitor, 12.5 μ Farad, 250VAC Motor Run 4 807-2572 Microswitch 5 Resistor Assembly 806-8530SP 100-120V Modular Basket Lift (see Note 2 in illustration) 106-2771 208-250V Modular Basket Lift 6 809-0082 Ring, Truarc Retaining[...]
-
Page 60
2-4 2.3 Cabinetry 2.3.1 Backs, Doors, Flue Caps, Sides, and Top Caps 1 2 3 5 7 8 9 4 6 10 12 11 13 14 8 17 18 19 20 21 22 23 15 16 24[...]
-
Page 61
2-5 ITEM PART # COMPONENT 1 Back, Single Uppe r 210-6581 Stainless Steel 200-6581 Cold Rolled Steel 2 Back, Sin g le Lowe r 210-6580 Stainless Steel 200-6580 Cold Rolled Steel 3 Back, Double U pp er (f or 2-, 4-, and 5- s tation f r y ers – does not include Items 7 -9 ) 210-6542 Stainless Steel 200-6540 Cold Rolled Steel 4 Back, Double Lower (f o[...]
-
Page 62
2-6 2.3.2 Filter Cabinet Bases, Casters, Framing, and Related Components NOTE: 2- and 3-st ation fryers have 4 casters; 4- and 5-stat ion fryer s have 6. See Page 2-4 f or upper hinges . 1 2 3 4 5 6 7 8 11 9 10 12 13 14 15 16 17 20 21 18 19 31 31 25 25 25 27 26 30 32 33 33 32 31 The 5-station cabinet illustrated is typical of all Pro Series (H50/55[...]
-
Page 63
2-7 ITEM PART # COMPONENT 1 Frame, Control Panel 106-3902SP Two-Station, Standard (use 106-5221SP mfd. After 3.15.06) (use 106-6082 for fall back) 106-3903SP Three-Station, Standard (use 106-5018SP mfd. After 3.15.06) (use 106-6086 for fall back) 106-3904SP Four-Station, Standard (use 106-5019 mfd. After 3.15.06) (use 106-6087 for fall back) 106-39[...]
-
Page 64
2-8 2.3.3 Non-Filter Cabinet Bases, Casters, Framing, and Related Components NOTE: 2- and 3-station fryer s have 4 caster s; 4- and 5-station fryers have 6. See Page 2- 4 for uppe r hinges. The 5-station cabine t illustrated is typical of all Pro Series (H50/55) gas non-filter cabinets. All base and framing compo nents used in Pro Series (H50/55) g[...]
-
Page 65
2-9 ITEM PART # COMPONENT 1 Fram e, Control Panel 806-4732 Single-Station, Standard (use 106-5016 mfd. After 3.15. 06) (use 106-6079 for fallback) 106-3902SP Two-Station, Standard (use 106-5221SP mfd. After 3. 15.06)(use 106-6082 for fallback) 106-3903SP Three-Station, Standard (use 106-55018SP mfd. After 3. 15.06)(use 106-6086 for fallback) 106-39[...]
-
Page 66
2-10 2.4 Controllers SOLID STATE 1 2 3 4 ITEM *Standard PART # *Euro-Look PART # COMPONENT 1 Computer Magic III.5 106-1151SP 106-3446 Dual-vat (Domestic U.S.) 106-1187SP 106-3447 Dual-vat (CE) (use 106-3450 for 8-second MC Non-CE export uni ts) 106-1150SP 106-3445 Full -vat (Domestic U.S.) 106-1188SP 106-3448 Full-vat (CE) (use 106-3449 for 8-secon[...]
-
Page 67
2-11 2.5 Drain, Filtration, and Oil Return System Components 2.5.1 Filtration System Components[...]
-
Page 68
2-12 ITEM PART # COMPONENT 1 108-0181SP Filter Pan, Slid e-type, FootPrint Pro (after July, 2008; includes plug and o-rings) 813-0568 Plug, 1/8-inch NPT Socket Head 816-0596 O-Ring (two required) * 826-1980 Filter Pan, Roller-ty pe, FootPrint Pro (prior to July, 2008; includes next 4 items) 813-0568 Plug, 1/8-inch NPT Socket Head 816-0012 O-Ring (t[...]
-
Page 69
2-13 2.5.2 Drain Valves and Associated Components[...]
-
Page 70
2-14 ITEM PART # COMPONENT 1 810-1569 Valve Assembly, 1.25-inch Full-Vat Non-Filter Drain (includes handle) * 810-1427 Lock Pin Handle for 1.25-inch Valve Assembly 2 806-7915SP Valve Assem bly, 1-inch Left Dual-Vat Non-Filter Drain (complete assembly) 3 806-7916SP Valve Assem bly, 1-inch Right Dual-Vat Non-Filter Drain (complete assembly) 4 809-058[...]
-
Page 71
2-15 2.5.3 Oil Return Line Components There are more tha n 160 oil return line combinations. The three example s shown are typical. These examples identify all of the components used in the vari ous con- figurations, but not all o f the components identified are used in every configuration or in only the position shown. FPPH55 0/555 (FV, FV, DV, FV[...]
-
Page 72
2-16 ITEM PART # COMPONENT 1 807-2484 Valve, 1/4-inch NPT Solenoid 2 810-0278 Valve, 1/2-inch NPT Ball 3 806-8762SP Valve Assem bly, Microswitch and Ball 4 900-5953 Handle, Oil Discharge Valve 5 814-0047 Sleeve, Red Handle 6 900-8057 Mount, Microswitch 7 809-0354 Screw, 4-40 X 3/4-inch Slotted Round Head 8 807-2103 Microswitch, Lever Activated 9 80[...]
-
Page 73
2-17 2.5.4 Oil Return Handle, Oil Disposal and Disposal Hose Components Left Hand l e and Linkage (Standard) 1 2 3 4 6 5 7 9 10 11 5 6 12 13 14 13 15 16 17 18 19 1 5 6 4 2 3 8 9 10 11 17 19 18 12 13 14 16 15 19 1 2 3 10 6 5 11 13 15 20 16 4 5 6 21 12 14 13 806-9330SP 36 35 34 39 38 40 25 24 33 32 42 41 27 31 Det ai l of I t em 27 28 1 0 2 30 29 3 1[...]
-
Page 74
2-18 ITEM PART # COMPONENT 1 807-2103 Microswitch, Lever Activated 2 826-1359 Screw, 4-40 X 3/4-inch Slotted Round Head 3 809-0237 Nut, 4-40 Hex Keps 4 200-0821 Bracket, Handle 5 809-0247 Nut, 8-32 Hex Keps 6 826-1363 Screw, 8-32 X 1/2-inch Slotted Truss Head (pkg. of 25) 7 901-2358 Cover, Left Handle Microswitch 8 902-2358 Cover, Right Handle Micr[...]
-
Page 75
2-19 2.5.5 Oil Disposal Wand Assembly 1 2 3 ITEM PART # COMPONENT 806-7459 Assembly, Oil Disposal Wand 1 810-0603 Wand, FB Filter 2 810-1471 Hose, 24 FPH50/55 3 810-0490 Quick Disconnect, ¼-inch Female 2.5.6 Assembly Wand Plumbing (Japan) 1 2 12 3 14 10 15 11 5 4 9 13 8 6 16 7 ITEM PART # COMPONENT 806-9700SP Plumbing Assembly, Japan Wand 1 807-21[...]
-
Page 76
2-20 2.5.7 Rear Flush Oil Return Components 21 (All components except for Items 4 and 5 are the same for Right a nd Left Oil Re turn Valve Assemblies) Nut (furnished with Item 8) 15 19 11 10 2 3 12 4 5 6 7 8 6 18 16 17 13 14 22 23 24 20 22 9 4 Front Filter Handle 1 (Full Vat Left /Dual Vat Righ t shown) 22 22 9 9 9 25 9 9a[...]
-
Page 77
2-21 ITEM PART # COMPONENT 1 Valve Assembly, Microswitch and Ball Valve 106-3452 Valve, Rear Flush Assembly, Left Side 106-3453 Valve, Rear Flush Assembly, Right Side 2 810-2493 Elbow, 90º x ¼-inch NPT x ¼-inch Tube 3 809-0601 Clip, Rod End Clevis 4 Shaft, Rear Flush Valve 211-6701 For use in Left oil return valve assemblies 212-6701 For use in [...]
-
Page 78
2-22 2.5.8 Power Shower Assemblies (Optional) 2 1 3 4 ITEM PART # COMPONENT 806-4442SP Power Shower Assembly, Full-vat, Complete 806-4476SP Power Shower Assembly, Dual-vat, Complete 1 814-0001 Grip, Handle 2 809-0415 Screw, Cleanout 3 826-1390 Seal (Gasket) (pkg. of 5) 4 826-1344 O-Ring (pkg. of 5)[...]
-
Page 79
2-23 2.6 Electronics and El ectrical Components (for Controllers, Page 2-10) 2.6.1 Component Boxes[...]
-
Page 80
2-24 ITEM PART # COMPONENT 1 810-1164 Block, One-Piece Screwless Terminal 2 200-5996 Box, One-Piece Component 3 807-1926 Bushing, .875-inch Split 4 826-2024 Cable, 21-inch Ignition (comes with Rajah connector [Item 5]) 5 807-3484 Connector, Rajah 6 106-0531SP Fuse Assembly, Inline 7 816-0217 Insulation, Terminal Block Paper 8 807-2971 Ignition Modu[...]
-
Page 81
2-25 2.6.2 Transformer Boxes 1 4 15 20 30 18 22 25 13 30 2 12 34 30 17 30 11 27 23 14 10 1 4 15 20 30 18 22 25 13 30 2 34 3 30 17 30 11 27 23 14 20 30 A B C 5 8 15 9 6 7 20 30 13 30 20 30 20 30 35 33 32 31 26 30 17 30 11 18 22 25 28 24 14 D 1 4 15 19 30 19 30 18 22 25 27 23 14 30 11 13 30 2 34 3 30 16 E 13 30 2 34 3 19 30 19 30 19 30 18 22 25 30 11[...]
-
Page 82
2-26 ITEM PART # COMPONENT Box Assembly, Transformer A 106-1380SP 100-120V FMPH150/155, FMPH350/355, FMPH450/455 B 106-0627SP 100-120V FMPH250/255, FMPH350/355, FMPH450/455, FPPH250/255, FPPH350/355, FPPH450/455 C 106-3308SP 100-120V FMPH450/455, FPPH350/355 D 106-3433SP 208-240V FMPH250/255 CE/Non- CE Export, FPPH250/255 CE/Non-CE Export E 106-343[...]
-
Page 83
2-27 2.6.3 High-Limit Thermostat and Temperature Probe ITEM PART # COMPONENT 1 826-1177 High Limit Thermostat - 425 ° F/218 ° C 2 806-4206 Temperature Probe 3 210-0681 Probe Guard[...]
-
Page 84
2-28 2.7 Frypots and Associated Components 2.7.1 Full-Vat Frypot Components 1 41 10 38 3 29 21 40 7 16 13 14 17 35 18 33 15 22 36 11 25 30 37 23 26 8 5 12 31 6 39 9 20 4 24 32 13 34 17 40 7 21 27 19 2 All insulation and gaskets can be ordered in a sing le kit, P/N 826-0929. Kit 826-0931 contains th e insulation and gaskets required when replacing b[...]
-
Page 85
2-29 ITEM PART # COMPONENT 1 106-1019SP Flue Assem bly, Full-vat 2 200-0936 Back, Left Full-vat Combustion Chamber 3 200-0937 Back, Right Full-vat Combustion Chamber 4 200-2227 Retainer, Full-vat Upper Insulation 5 809-0059 Nut, 1/4-20 Flange Hex 6 809-0361 Screw, #8 X 1/2-inch Hex Head Drill Point 7 809-0362 Screw, #8 X 1 1/4-inch Hex Washer Head [...]
-
Page 86
2-30 2.7.2 Dual-Vat Frypot Components[...]
-
Page 87
2-31 ITEM PART # COMPONENT 1 106-1018SP Flue Assem bly, Dual-vat 2 200-0941 Back, Dual-vat Combustion Chamber 3 200-2229 Retainer, Dual-vat Upper Insulation 4 809-0059 Nut, 1/4-20 Flange Hex 5 809-0360 Screw, #8 X 3/8-inch Hex Head 6 809-0362 Screw, #8 X 1 1/4-inch Hex Washer Head Drill Point 7 809-0435 Washer, Steel 8 809-0500 Screw, #10 X 1/2-inc[...]
-
Page 88
2-32 2.8 Gas Supply and Combustion Sy stem Components PH250/255 Full Vat Gas Manifold (Typical) The example illustrat ed is typical of PRO Series Fryer Gas Manifolds. Each manifold is assembled from stand ard 1/2- , 3/4-, and 1-inch NPT black iron pipe nipples, elbows, tees, plugs, and unions, which may be locally aquired . 3 4 5 Use the universal [...]
-
Page 89
2-33 ITEM PART # COMPONENT 1 Ignitor (includes gasket 816-0059, which may be ordered separately) 826-0981 Natural Gas (G20, G25) 826-0982 Propane (G30, G31) 826-1002 Manufactured Gas 2 826-1371 Screw, #8 X 1/2-inch Hex Head (pkg. of 25) 3 Blower Assembly, Combustion Air (includes harness and Items 4, and 5) 106-2996SP 100V 50/60 Hz (Left) 106-2999S[...]
-
Page 90
2-34 2.9 Gas Valves and Associated Components Non-CE Gas Valve Assembly (Typical) CE Gas Valve Assembly (Typical) 5 1 2 3 4 6 7 8 9 10 11 12 13 14 15 13 22 16 18 17 19 20 21 10 11 23 NOTE: The gas tube and enrichment tube fittings are assembled in varying configurations depending upon the location of the valve and whether the associated frypot is a[...]
-
Page 91
2-35 ITEM PART # COMPONENT 1 Valve, Non-CE Gas 826-1122 Natural Gas (G20, G25) 826-1123 Propane Gas (G30, G31) 2 810-1715 Valve, CE Gas (G20, G25, G30, G31) 3 810-1041 Accessory Kit (contains parts to adapt Item 2 to specific fryer configur ation) 4 806-9678SP Plug Assem bly, CE Gas Valve 5 810-0494 Ferrule (Nut), Orifice 6 810-1355 Gas Line, 3/8-i[...]
-
Page 92
2-36 2.10 Wiring Assemblies and Harnesses Filter A ssociated Wiring 1 2 3 ITEM PART # COMPONENT 1 810-1062 Cable, Filter Box Lower 9- Pin Plug to 807-2000/2001 C2 Connector * 807-2000 Cable, 810-1062 C2 Connector to Com ponent Box (units w/Basket Lift) 2 807-2001 Cable, 810-1062 C2 Connector to Com ponent Box (units w/o Basket Lift) * 812-0362 Spag[...]
-
Page 93
2-37 Main Wiring Harnes ses U.S. and Non -CE harness (shown) has two u ntermin ated wire s . Untermin ated wire s. CE harness h as two unt erminat ed wires plus two additional wires with push- on term inals . ITEM PART # COMPONENT 807-1978 U.S. and Non-CE Export Main Wiring Harness 807-2168 CE Main Wiring Harness 807-4014 U.S. and Non-CE Export Mai[...]
-
Page 94
2-38 2.11 Miscellaneous Connectors and Terminals 1 2 4 5 3 6 7 9 10 8 11 13 12 ITEM PART # COMPONENT 1 807-1068 2-Pin Female 2 807-0158 6-Pin Female 3 807-0156 9-Pin Female 4 807-0159 12-Pin Female 5 807-0875 15-Pin Female 6 807-1067 2-Pin Male 7 807-0157 6-Pin Male 8 807-0155 9-Pin Male 9 807-0160 12-Pin Male 10 807-0804 15-Pin Male 11 826-1341 Te[...]
-
Page 95
3-1 PRO H50/55-SERIES GAS FRYERS CHAPTER 3: SINGLE H50/55 UNIT UNIQUE PARTS LIST 3.1 Single H50/55 Filtra tion System Components ITEM PART # COMPONENT 806-9255SP Filter Pan Assem bly, FootPrint Pro Filter (includes Items 1, 2, 3, and 4) 1 823-2751 Pan Assembly, Filter 2 810-3537 Screen, Sana Grid 3 810-1406 Ring, Filter Paper Hold-Down Ring 4 810-2[...]
-
Page 96
3-2 3.2 Single H50/55 Oil Return Components 18 17 1 3 5 7 8 2 4 16 14 15 11 11 10 9 8 10 9 6 7 13 12 12 Dual-vat Oil Return Manifold Full-vat Oil Return Manifold ITEM PART # COMPONENT 1 108-1030 Mounting Bracket, Full-vat, Oil Return Valve 2 220-4255 Mountin g Bracket, Dual-vat, Oil Return Valve * 220-6187 Bracket, Valve ( used to attach Item 3 to [...]
-
Page 97
3-3 3.3 Single H50/55 Component Boxes[...]
-
Page 98
3-4 ITEM PART # COMPONENT 1 106-6708 Interface Board, SMT, Gas, non-Basket Lift, FV (U.S., Canada, Mexico) 2 826-2264 Interface Board, SMT, Gas, with Basket Lift, FV (U.S., Canada, Mexico) 3 106-6707 Interface Board, SMT, Gas, non-Basket Lift, FV (Export) 4 106-6711 Interface Board, SMT, Gas, non-Basket Lift, DV (FAST) 5 807-3366 Ignition Module, D[...]
-
Page 99
3-5 3.5 Single H50/55 Transformer Boxes ITEM PART # COMPONENT 1 900-2697 Transform er Box 2 900-2703 Cover, Front, Large 3 900-2709 Cover, Front, Small 4 900-2708 Cover, Transformer Box 5 806-6164 Harness Assembly, Domestic 6 106-6056 Harness Assembly, FAST 7 806-6637 Harness Assembly, CE 8 807-2176 Transformer, V/F Dual Voltage 100/120V 9 807-1999[...]
-
Page 100
Frymaster, L.L.C., 8700 Line Av enue, Shrev eport, Louisiana 71106 TEL 1-318 -865-1711 FAX (Par ts) 1-318- 219-7140 FAX (Tech Support) 1-318-21 9-7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 819-6083 JUNE 2009[...]