Go to page of
Similar user manuals
-
Scanner
Fujitsu M3096EX
53 pages 0.51 mb -
Scanner
Fujitsu ScanSnap fi-5110EOX
135 pages -
Scanner
Fujitsu fi-4530C
27 pages 2.22 mb -
Scanner
Fujitsu S1100
387 pages 19.77 mb -
Scanner
Fujitsu FI-5000N
122 pages 1.9 mb -
Scanner
Fujitsu M3099EH
100 pages 0.53 mb -
Scanner
Fujitsu FI-7180
7 pages 1.01 mb -
Scanner
Fujitsu M3091DC
63 pages 0.25 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu 8.4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu 8.4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fujitsu 8.4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fujitsu 8.4 should contain:
- informations concerning technical data of Fujitsu 8.4
- name of the manufacturer and a year of construction of the Fujitsu 8.4 item
- rules of operation, control and maintenance of the Fujitsu 8.4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu 8.4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu 8.4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu 8.4.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu 8.4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Scanner Utility for Microsoft Windows <32bit> Version 8 . 4 C150 - E2 13 - 02 EN[...]
-
Page 2
Introduction Thank you for purchasing the "Scanner Utility for Microsoft Windows V 8. 4 ". This software contains a TWAIN - compliant image scanner driver (simply called "d river" in this guide) and utilities. This guide provides a description summary of the driver, as well as a description of the installation method and procedu[...]
-
Page 3
ii Trademarks MS - DOS, Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation. IBM PC/AT and DOS/V are registered trademark of International Business Machi ne Corporation. Adaptec is a registered trademark of Adaptec Inc. EZ - SCSI is a trademark of Adaptec Inc. Other product names are the trademarks or registered tr[...]
-
Page 4
iii Organization This manual explains how to install and use this driver, and how to use the TWAIN scanning utility. • TWAIN This section gives an overview of the TWAIN specification. • Installation This section explains the procedure for installing the environments in which this driver may operate. • Using the Driver Th is section explains h[...]
-
Page 5
iv Contents 1. Outline .................................................................................................. 1 1.1 Characteristics of this Driver .................................................................................... 1 1.2 Operating Environment ..............................................................................[...]
-
Page 6
v 4.8.1 Gray ........................................................................................................................ 36 4.8.2 Ima ge Filter ............................................................................................................ 38 4.8.3 DTC .......................................................................[...]
-
Page 7
1 1. Outline 1.1 Characteristics of this Driver • This driver complies with TWAIN regulations V1. 8 (the lat est version as of May 2000), which are global standards for image scanners. The driver can be used in all TWAIN - compliant applications. • This driver also supports an image scanner that has the "double - sided scan" function.[...]
-
Page 8
2 1.3 Explanatory Notes The descriptions in this manual are prepared based on the following rules: ◊ Menus and buttons The menus and buttons used in th e program description are enclosed in []. Example: [File] menu , [ OK] button ◊ Keyboard The keytop indications comply with the standard keyboard of the Fujitsu FMV series. Major differences bet[...]
-
Page 9
3 1.4 Explanation of terms ◊ IPC option board IPC - 2/2D in this guide refers to the IPC - 2 and IPC - 2D image processi ng circuit. IPC - 3/3D in this guide refers to the IPC - 3 and IPC - 3D option board.[...]
-
Page 10
4 2. TWAIN 2.1 TWAIN TWAIN is the specification that defines the standard software protocol and application programming interface (API) for data exchange between a software app lication program and an image input device such as the image scanner. [TWAIN development background] In the past, development of a new scanner inevitably required the develo[...]
-
Page 11
5 • Application software (photo retouch ing software, etc) ‚ Source manager ( TWAIN.DLL/TWAIN_32.DLL, etc ) ƒ Source (Image scanner control of the driver, etc) Image scanner , etc. Figure TWAIN Application[...]
-
Page 12
6 3. Installation 3.1 Preparation 1. Check that the operating system is installed correctly. 2. Check that the SCSI adapter is connected to the computer . 3. Check whether the SCSI driver and ASPI manager are installed correctly and operating (For windows 2000, 4.60 or later) Note Version 4.01 or later of the ASPI Manager is required. Use Explo[...]
-
Page 13
7 Figure Fujitsu TWAIN gr oup * For the FUJITSU Scanner Control Center, the Gamma Pattern Editor and the Firmware Updater, see section 6, 5, and 7 respectively.[...]
-
Page 14
8 3.3 Uninstall The uninstall process removes the software and returns the hard disk to its pre - installation state. 1. Click on [Start], followed by [Settings], and then [Control Panel]. The Control Panel is then displayed. 2. Double - click on "Add/Remove Programs" from the icon list of the Control Panel. The panel of properties of [Ad[...]
-
Page 15
9 4. Using the Driver 4.1 Selecting the Driver To use this driver from the TWAIN application, select "FUJITSU TWAIN32" from the TWAIN data source (driver) selection screen. For general application, the data source selection screen is display ed by selecting the [Select Scanner] or [Acquire ...] menu. Refer to the instruction manual for th[...]
-
Page 16
10 4.2 Screen Configuration Figure Main Dialog The following pages contain the explanation and operation description for ea ch part.[...]
-
Page 17
11 4.3 Displaying Driver Information ♦ Image scanner name The model name, option port name, and capacity of internal scanner memory (in units of megabytes) of the connected image scanner are displayed. If no image scanner is connected, this field is blank. To change the selected scanner, click the [Select ...] button to display a list of connecte[...]
-
Page 18
12 ♦ Data size The approximate amount of data per image w hen data is scanned in the present option. Note This value is the amount of uncompressed data. The size of the stored file will differ from this value and is usually smaller if image compression is chosen and the image is compressed. 4.4 Setting Inform ation on Image Scanning ♦ Current s[...]
-
Page 19
13 ♦ Paper Size Selects a paper size corresponding to the size of the document to be scanned. Select a standard paper size from the list or [Custom]. If [Custom] is selected, the "Custom Paper Size Setting" dialog appears. Enter the size of the document to be scanned. (In this case, specify the paper size by width x length for the sc an[...]
-
Page 20
14 ♦ Scan Type Selects the feeding device. The image scanner uses a document bed called the flat bed as well as an automatic document feeder (ADF) for feeding scanned document. The ADF usually enables the documents to be scanned only once. The flat bed allows scanning the same documents repeatedly. ♦ Flatbed Reads a document placed on the flat [...]
-
Page 21
15 ♦ Long page (front and backside) In the same case as that for scanning the front of a long page, this option is selected in order to scan the entire side of a long page whose length exceeds the vertical size of an A3 sheet. If this option is selected, the document is scanned in the "front to back to front to back … " order. Paper f[...]
-
Page 22
16 Color Scans data using 24 bits color. This mode is suitable for scanning color photograph and employs far more memory that Gray scale mode. Some versions of the scanner do not support this scann ing mode. For details contact the retail store where the device was purchased. Automatic separation This option specifies whether to distinguish line dr[...]
-
Page 23
17 ♦ Halftone Selects the halftone pattern for halftone scanning from the built - in pattern list. Select the desired halftone pattern for displaying the obt ained image. This setting is effective when "Halftone" or "Automatic Separation" is selected in "Image Mode ". Dither Pattern 0 Executes pattern processing that[...]
-
Page 24
18 This parameter can be set if "Halftone" or "Automatic Separ ation" is selected for "Image Mode ." ♦ Threshold: Sets the threshold value by which the black and the white of black - and - white images are distinguished. Specify a number in the range of 1 (bright) to 255 (dark). This parameter can be set only if &quo[...]
-
Page 25
19 ♦ Contrast: Sets the contrast of light and shadow in a scanned image. Specify the contrast with a number in the range of 1 (low [soft]) to 255 (high [sharp]). The contrast can be set if "Gray Scale" is selected in "Image Mode . " If this value is increased, the dark part of the image is shown darker and the light part is sh[...]
-
Page 26
20 Progress indicator ♦ [Close] / [ OK ] Closes the dialog box without scanning. If a setting is changed, the changed setting is saved in the initial value file. ♦ [Reset] Restores the current setting values to the status immediately after the window is opened. ♦ [Help] Displays online help. When the [F1] key is pressed, help information rega[...]
-
Page 27
21 ♦ [ Advance ] Displays the "advance dialog " for settings related to color variance and image processing. ♦ [Config] Displays the "basic scan dialog" for managing the settings file and for setting simple scan dialog switching. ♦ [About] Express the version of this driver by clicking this button. 4.6 Setting "Scanni[...]
-
Page 28
22 4.7 Setting Options The "option dialog" is used to set device - specific functions and the items that differ depending on whether the scanner used supports them. The option specification is divided into "Rotation", "Job/Cache", "Generic", "Imprinter (Endorser)" and "Start Up". . The sup[...]
-
Page 29
23 The options are described below: 4.7.1 Rotation Figure Option dialog (Rotation) ♦ Flip Side Rotation Specifies the binding of the document when both sides are scanned using ADF. Book Outputs the scanned image for both sides as is. Select this option to scan documents bound on the left or right s ide. Fanfold Outputs the scanned image of the ba[...]
-
Page 30
24 ♦ Rotation Degree Outputs the scanned image rotated to the right or left 90 degrees. 0.0 degree Outputs the scanned image as is. 90.0 degree Outputs the scanned image rotated 90 degrees to the right (clockwise). - 90.0 degree Outputs the scanned image rotated 90 degrees to the left (counterclockwise). 180.0 degree Outputs the scanned image rot[...]
-
Page 31
25 4.7.2 Job/Cache Figure Option dialog (Job/Cache) ♦ Caching Specifies whether to pre - read (cache) when a document is scanned . This option enables faster scanning. If processin g of the application being used slows down and scanning stop s , this option can be used to prevent degradation of the scanning speed. (The effect, however, depends on[...]
-
Page 32
26 Ram cache Pre - reads the allowable amount based on the allocated memory size and stores the data in PC memory. A memory size between 1 and 200 MB ca n be set. Use Memory on Scanner Pre - reads using the memory installed in the scanner (displayed only if supported by the scanner). ♦ Batch Detection The application can detect documents on a spe[...]
-
Page 33
27 ♦ Double Feed Detection This option detects a double feed ( occurs when two or more documents are sent) based on the s et condition. If a double feed is detected when this setting has been turned on, the device will stop and an error message output. None Double feed detection is not performed. Hardware Setting A d ouble feed is detected based [...]
-
Page 34
28 This option is valid only when the cache setting is set to [Use Memory on Scanner]. In addition, this option cannot be used unless it is supported by the scann er. *1: Ratio of black dots included in the scanning area (for blank pages)[...]
-
Page 35
29 4.7.3 Generic Figure Option dialog (Generic) ♦ Unit/Scaling This option selects the unit for the scanning area and preview window. One inch is calculated as 25.4 millimeters . When inches are converted to millimeters, values are rounded off. Note The TWAIN specifications require that the data width be arranged in units of 32 bits. As a result,[...]
-
Page 36
30 4.7 .4 Imprinter (Endorser) Figure Option dialog (Imprinter) ♦ Enable Imprinter ( Endorser ) Specifies enabling or disabling the imprinter function of the device. When the option is selected and scanning has been completed, the scanned originals are imprinte d according to the instructions below. This applies only to the imprinter option. Ther[...]
-
Page 37
31 from the tail of strings against to the direction of scanning, designate “ Bottom to Top ” However, see the “ Relevant Image Scanner Specification ” described in the Appendix since the available settings depend on the device. ♦ Initial Value (Counter) Designates the initial count when the Imprinter S tring is set, including a counter v[...]
-
Page 38
32 %DD: The day is printed using two digits; for example, 03 for the 3rd day of the month and 26 for the 26th day of the month. %D: The day is printed using one or two digits; for example, 3 for the 3rd day of the month and 26 for the 26th day of the month. %HH: The hour is printed using two digits of the 24 - hour clock; for example, 08 for 8:00 a[...]
-
Page 39
33 4.7.5 Start Up Figure Option dialog (Start Up) ♦ Power Mode − Quick S tart M ode T his mode keeps the lamp o n regardless the scanner ’ s operating condition, which saves times for lamp to become steady. − Low P ower M ode To save the power consumption, this mode turns the lamp off, if the scanner is not operated for 14minutes. ♦ Enabl[...]
-
Page 40
34 − Enable Scanner Panel This is to specify whether the operator panel is enabled or not. If this is checked, button operation on the operator panel becomes effective. − Enable Scanner Dial Specifies whether the value indicated by the density dial on the scanner is reflected on scanning or not. This setting is valid when both “ Enable Scanne[...]
-
Page 41
35 4.8 Setting Advance Options The "advance dialog" is used to set items related to image processing. Th e settings apply to device - specific functions and items that differ according to whether the scanner used supports them. The advance option specification is divided into "Color Variance", "Image Processing", and &[...]
-
Page 42
36 The options are described below: 4.8.1 Gray Figure Advance dialog (density correction) ♦ Gamma Pattern This option corrects distorti ons from nonlinear image representation. Scanner sensors are generally designed to generate output linear to the density of the light reflected from the document. However, most output terminals do not produce out[...]
-
Page 43
37 When "Download Pattern" is selected, the above dialog box opens. Select the gamma pattern download file to be used from the list of file names. Then, press the [OK] button. Correction will then be executed using the selected gamma pattern. If the gamma pattern download file has not been registered in the list of fil e names, use the [A[...]
-
Page 44
38 ♦ Dropout Color This option enables scanning excluding the selected color information of green, red, or blue (the three primary colors of light). For example, t o scan black characters framed in red, selecting red for scanning will scan only the black characters. ♦ Reverse This option specifies whether to reverse the black and white of a sca[...]
-
Page 45
39 ♦ Edge Processing This option specifies the sharpness of a scanned image. Select "None", "Edge Extract", or "Smoothing (Background Removal)". None Edge processing is not per formed. Edge Extract This option outputs an image with the edge extracted. If this option is selected, the boundary between the black part an[...]
-
Page 46
40 4.8.3 DTC This option is valid only when "Simple auto binary" is set. Figure Advance dialog (DTC Mode) ♦ Scan mode This option selects one of the following two scan modes: [for OCR]: This mode is for text recognition applications where irregularity in the image is undesirable. [for Image]: This mode is for image scanning applications[...]
-
Page 47
41 ♦ Density curve This option specifies the relationship between the threshold value and the maximum density. This specification method depends on the [Scan mode] setting. In [for OCR] mode, use the slider to set the inclination and density level. To specify the value, drag the tab of the slider to the desired setting posi tion. The current sett[...]
-
Page 48
42 ♦ OCR Smoothing/ Background Removal The OCR smoothing is the function to make smooth the notched part of line - drawing, and the Background Removal is the function to remove the uneven background. These functions are enabled when it is selected. For further information, please refer to the User ’ s guide attached to the IPC board since the f[...]
-
Page 49
43 4.8.4 When Color is specified For color devices, if Color is selected in the image type, dialog display change s as follows. Figure Advance dialog (Color) <Image Mode : Color selected> ♦ Shadow/Highlight Shadow : The highlight allows the darkest part of the document to be controlled. The higher the shadow value, the darker the image. Hig[...]
-
Page 50
44 Contrast : Sets the contrast of light and shadow in a scanned image. Specify the contrast with a number in the range of 1 (low [soft]) to 255 (high [sh arp]). If this value is increased, the dark part of the image is shown darker and the light part is shown lighter. Some scanner models do not support this function. See "Relevant Image Scann[...]
-
Page 51
45 Figure Advance di alog (Quality) <Image Mode : Color selected> ♦ Image Emphasis This option specifies the sharpness of a scanned image. Select "None", "De - Screen" or "Emphasis". None Edge processing is not performed. Emphasis This option outputs an image with the edge e mphasized. "Emphasis High"[...]
-
Page 52
46 De - Screen "De - Screen Level 1", "De - Screen Level 2 ", "De - Screen Level 3", or "De - Screen Level 4" can be selected. This option eliminate moirés patterns. To eliminate more effectively, higher level is selected. ♦ White Level Follower Select this option to scan a document whose background color [...]
-
Page 53
47 4.9 Setting the Configuration Options These options are us ed to manage the setting files , and switch the basic scan dialog display. Press the [Config] button of the main dialog to open the [Configuration] dialog box shown below. Figure Option dialog box (simplified DTC) ♦ Setting Files The setting informati on of the scan conditions can be s[...]
-
Page 54
48 ♦ FTS File Information The information of the setting file selected in [Setting Files] is displayed. ♦ [Show this dialog next open] checkbox If this checkbox is checked, [Basic Scan Dialog] will be activated the next time the driver is activated. ♦ [OK] bu tton Makes the new setting valid, closes this dialog box, and returns to the main di[...]
-
Page 55
49 Filename: Spe cify the name of the file used to save the settings. ♦ [Delete] button Deletes unnecessary setting files. Select the setting file to be deleted and then press the [Delete] button. A confirmation dialog will be displayed. Press the [OK] button to delete the setting file. To cancel, press the [Cancel] button. ♦ [Help] button Disp[...]
-
Page 56
50 4.10 Basic Scan Dialog The basic scan dialog contains only the minimum functions required for scanning. The detailed setting functions of the main dialog ha ve been omitted. Scanning can be easily performed by selecting a registered setting file. The basic scan dialog is also useful for avoiding incorrect operations when standard work is perform[...]
-
Page 57
51 ♦ FTS Fil e Information The contents of the selected file are d isplayed. ♦ [Scan] button Executes scanning based on the contents of the setting file. ♦ [OK] button Terminates without performing the scan operation. ♦ [Adjust] button Switches from the basic scan dialog to the main dialog. ♦ [Help] button Displays online help. ♦ [Show [...]
-
Page 58
52 4.11 Download Pattern File The "download pattern file" of this driver is a file that defines the patterns to be used by the scanner to execute various image processing. This file is available in the following two versions. Each version can be selected using the [Download Selection Dialog] that opens when [Download] is selected. The fil[...]
-
Page 59
53 Example 8, 8, 128, 128, 128, 128, 128, 128, 128, 128, 255, 128, 128, 128, 128, 128, 128, 128, 255, 255, 128, 128, 128, 128, 128, 128, 255, 255, 255, 128, 128, 128, 128, 128, 255, 255, 255, 255, 128, 128, 128, 128, 255, 255, 255, 255, 255, 128, 128, 128, 255, 255, 255, 255, 255, 255, 128, 128, 255, 255, 255, 255, 255, 255, 255, 128,[...]
-
Page 60
54 ♦ Gamma download pattern file Any user defined gamma correcti on processing can be performed by downloading the pattern from the gamma download file to the scanner. The defined pattern becomes effective when [Download Pattern] is selected for [Gamma Pattern]. Some models do not support this file. See "Relevant Ima ge Scanner Specification[...]
-
Page 61
55 Example 256, 256, 255, 254, 253, 252, 251, 25 0, 249, 248, 247, 246, 245, 244, 243, 242, 241, 240, 239, 238, 237, 236, 235, 234, 233, 232, 231, 230, 229, 228, 227, 226, 225, 224, 223, 222, 221, 220, 219, 218, 217, 216, 215, 214, 213, 212, 211, 210, 209, 208, 207, 206, 205, 204, 203, 202, 201, 200, 199, 198, 197, 196, 195, 194, 193, 192, 191, 190[...]
-
Page 62
56 5 . Using the Gamma Pattern Editor 5 .1 Start - up Click on "Start" and select "Downloa d Pattern Editor" from "Scanner Utility for Microsoft Windows" under "Programs." The following menu is displayed: Figure Gamma Pattern Editor Tool start - up menu[...]
-
Page 63
57 5 .2 [File] menu ♦ [Load] This menu is used to read the Gamma Download file and display t he graph and gradations. The name of the open file is displayed above the graph area. ♦ [Save] The gamma pattern currently being edited is saved in the file whose name is displayed above the graph area. If no filename is displayed, the pattern is named [...]
-
Page 64
58 5 .3 [Help] menu ♦ [About] Informatio n related to this editor and its version number is displayed.[...]
-
Page 65
59 5 .4 Gamma Pattern Editing ♦ Graph Area The graph area is a 256 - dot × 256 - dot white square area bordered by black lines, where the relationship between the input values of 0 to 255 (x axis) and output values of 0 to 255 (y axis) is indicated in blue lines. Each graph dot represents one division (unit). ♦ Gradation The input is displayed[...]
-
Page 66
60 6. How to Use the FUJITSU Scanner Control Center 6.1 Outline This software that is resident in the system continuously monitors the scanner connected and starts the target application in resp onse to an instruction from the operation panel in the scanner. (Pressing the start button on the scanner starts the application that has been set in advan[...]
-
Page 67
61 Right - clicking the icon displays the following pop - up menu. Left - clicking th e icon displays the scanner being connected as shown below. The scanner that has been monitored by this application is indicated with a check mark. 6.3 Pop - up Menu ♦ [Rescan Scanner] Rescans the scanner that is currently connected. A scanner that is not recogn[...]
-
Page 68
62 ♦ [Path] Specifies a file name of the application to be started with its absolute pathname . A file can be also selected directly by using the [ … ] button. ♦ [Argument] Specifies an argument to be passed when starting the specified application. (This item can be omitted.) ♦ [Start in] Specifies a default folder for starting the applicat[...]
-
Page 69
63 ♦ [Use Plug - In] Checking this check box specifies a plug - in. (A plug - in is an additional program f or adding a new function to the application.) ♦ [Setting] Sets a plug - in in accordance with the following procedure: • Pressing the [Setting] button after selecting a target plug - in name in the plug - in list displayed displays the [...]
-
Page 70
64 Selecting "Yes" displays a dialog box below. (If "No" is selected, the function to start any application when the start button in this application is pressed is disabled.) Pressing the [OK] button after selecting one of function keys from F1 to F3 enables assigning a function key to the start button. If the [Cancel] button is[...]
-
Page 71
65 Left - clicking the task tray icon displays connected scanner names on the pop - up menu. It is also possible to select a scanner on this menu. ♦ [Help] Displays help information concerning to this application. ♦ [Abou t] Displays version information concerning to this application. ♦ [Exit] Terminates this application.[...]
-
Page 72
66 7. Using the Firmware Updater This application software is used to update the firmware installed in the scanner device. However, this application softwa re is automatically executed when the driver installation is completed. If the software is executed at the installation, it is not necessary to execute again. This application software shall be [...]
-
Page 73
67 When the following dialog box appears, press the [OK] button. The firmware update has been completed successfully . Reactivate Windows.[...]
-
Page 74
68 8 . Troubleshooting 8 .1 Error Messages 8 .1.1 Messages from the TWAI N Driver • The input value is outside the range. Cause: A value exceeding the range allowed for an input item was input. User response: Input a value inside the allowed range. Refer to the input item or the image scanner specification for the range. • The input value is no[...]
-
Page 75
69 • The value for custom pap er is higher than the maximum scan size. Width needs to equal 279 mm or less and length needs to equal 420 mm or less. • The value for custom paper is higher than the maximum scan size. Width needs to equal 11 inch or less and length needs to equal 16.53 i nch or less. • The value for custom paper is higher than [...]
-
Page 76
70 • Cannot specify Individual Setting wi th Gray Scale. • Cannot specify Long Page Scan with Gray Scale. Cause: Gray Scale and Individual Setting are specified at the same time. Gray Scale and Long Page Scanning are specified at the same time. User response: Uncheck Individual Setting when speci fying Gray Scale. At Long Page scanning, select [...]
-
Page 77
71 • Cannot specify next words for filename. :;? ” <> | . Cause: The specified filename contains one or more of the following characters : :;? ” <> | . User response: Enter a file name that does not contain the above characters. Then, make the setti ngs again. • The image scanner cannot be found. Cause: Possible causes inclu[...]
-
Page 78
72 • No paper in the ADF Cause: Although ADF was selected as the paper feeding method, no paper is found in the document tray. User response: Select another paper feeding method or set the document in the document tray. • The hopper tray is open, or No paper in the ADF . Cause: The hopper tray cover is open , or there is no paper in the ADF. Us[...]
-
Page 79
73 • Ink cartridge is not installed in the imprinter properly. Please check it and try. Cause: The imprinter (Endorser) has no ink cartridge or the ink cartridge may be mounted improperly. User response: Check that the ink cartridge of the imprinter is mounted properly an d scan again. • Imprinter position is out of paper. Please check the impr[...]
-
Page 80
74 • Downl oad file not found. Cause: A file specified as a dither pattern or gamma pattern cannot be found. User response: Check that the download file is in the specified directory. Otherwise, use the file selection dialog to specify an available file. • Illegal format or data in download file. Cause: The format of the specified download file[...]
-
Page 81
75 • A general fault of the DAT_XXXXX response (internally). Cause: This is a program error that usually occurs during internal data transfer. This message involves the sub - messages described later. User response: Contact the retail store where the product was purchased or the nearest maintenance service center. • A general fault of the DAT_X[...]
-
Page 82
76 8 .1. 2 Error messages relating to gamma correction pattern editing • Enter a positive decimal value. Cause: A value other than a number has been entered as the gamma correction value. Alternatively , 0 or a negative value has been entered. User response: Reenter a valid value. • The file could not be created. Cause: The file for saving coul[...]
-
Page 83
77 8.1.3 Messages concerning to FUJITSU Scanner Control Center • Failed to start - up the application. Check t he setting of FUJITSU Scanner Control Center. • The setting of the path is blank. Check the setting of FUJITSU Scanner Control Center. • Can not find the specified file. Check if the specified path and file name is correct . • Can [...]
-
Page 84
78 • Scanner could not find although it searched again. Check the c onnection of the scanner and retry again Cause: The scanner power may not have been turned on or the cable may have been connected incorrectly. Otherwise, the OS may not recognize the scanner. User response: Make sure that the scanner power has been turn ed on and the cable has b[...]
-
Page 85
79 8.1.4. Messages relating to the Firmware Updater • The firmware updater is already running. Cause: The same application software is tried to execute conc urrently. User response: Use the one already executed. • ASPI manager has not been installed. Please install the ASPI manager. • ASPI manager of unsupported revision has been installed. P[...]
-
Page 86
80 • The applicable scanner is not connected or the driver is in use. Please connect the applicable s canner or close the application software using the driver. The process is cancelled. Cause: The scanner may not been connected properly or the driver may be used. User response: Check the connection of the device or close the application software[...]
-
Page 87
81 8.2 Device Trouble Relat ed to Operation • The [Scan] button is pressed, but scanning is not performed. Cause: Has the scanner power been turned on? Ha s the SCSI cable been connected correctly? Has the correct device type been selected using [Select TWAIN Input Device]? • The scanner appears to be operating, but no image is displayed. Cause[...]
-
Page 88
82 9. Appendix 9 .1 Relevant Image Scanner Specification Product: M3093GX 1 ( fi - 4320S) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed , scanner unit moving (flat bed), Automatic Document Feeder (ADF) Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400,[...]
-
Page 89
83 Product: M3093DG ( fi - 4320) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed , scanner unit moving (flat bed) Automatic Document Feeder (ADF) simultaneous double - sided reading Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical - scanning: 400, 300, 240, 200 dpi O[...]
-
Page 90
84 Product: M3096GX 1 ( fi - 4620S) Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed , scanner unit moving (flat bed), Automatic Document Feed (ADF) Light source: Xe discharge tube (Green) Ba sic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 30[...]
-
Page 91
85 Product: M3097G 1 Type: Desktop Image sensor: Reduced optical system Operating method: Document fixe d , scanner unit moving (flat bed), Automatic Document Feed (ADF) Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200 dpi [...]
-
Page 92
86 Product: M3097DG Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed , scanner unit moving (flat bed), Automatic Document Fe ed (ADF) Simultaneous double - sided reading Light source: Xe discharge tube (Green) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolutio[...]
-
Page 93
87 Product: M3099G, M3099GX Type: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double - sided reading Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 200 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 300, 240, 200, dpi With [...]
-
Page 94
88 Image processing function: Simplified Dynamic Threshold ( SDTC) With image processing option Edge emphasis, Edge extraction, Automatic separation, Mirror image, Reverse image, Dynamic Threshold ( DTC) , Smoothing, Filtering, Noise remov al Imprinter ( Endorser ) : With imprinter ( endorser ) option (Reverse side, minimum left margin printing pos[...]
-
Page 95
89 Product: M3099GH Type: Desktop Image sensor: Reduced optical s ystem Operating method: Automatic Document Feed (ADF), simultaneous double - sided reading Light source: Fluorescent tube (Green) Basic resolution: Horizontal scanning: 200 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resolution: Standard: 400, 3 00, 240, 200, dpi with image [...]
-
Page 96
90 Imprinter ( Endorser ) : With imprinter ( endorser ) option (Reverse side, minimum left margin printing position of 20 mm) 1 Maximum number of characters to be printed: 20 characters Counter display range: 0 to 65535 (5 digits display) Direction(Printing): Top to Bottom Interface: SCSI -II Job control: Enabled Use of FUJITSU Scanner Control Cent[...]
-
Page 97
91 Product: fi - 4640S Type: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed , Automatic Document Feed (ADF) Long page scanning (297mm x 1387mm) Light source: Xe discharge tube( Green ) Basic resolution: Horizontal scanning: 400 dpi Vertical s canning: 800,700, 600, 500, 400, 300, 240, 200 , 150, 100 dpi Outpu[...]
-
Page 98
92 Imprinter ( Endorser ) : With imprinter option (Rever se side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) Direction ( Printing): Top to Bottom , Bottom to Top Interface: SCSI -II Job control[...]
-
Page 99
93 Product: M 4 097 D ( fi - 4750) Type: Desktop Image sensor: Reduced optical system O perating method: Document fixed Flat bed , Automatic Document Feed (ADF), simultaneous double - sided reading Long page scanning (297mm x 1387mm) Light source: Xe discharge tube( Green ) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700 ,[...]
-
Page 100
94 Imprinter ( Endorse r) : With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) D irection ( Printing): Top to Bottom, Bottom to Top Interface: SCSI -II Job control:[...]
-
Page 101
95 Product: fi - 4750L Type: Deskto p Image sensor: Reduced optical system Operating method: Document fixed Flat bed , Automatic Document Feed (ADF), simultaneous double - sided reading Long page scanning (297mm x 1387mm) Light source: Xe discharge tube( Green ) Basic resolution: Horizontal scann ing: 400 dpi Vertical scanning: 800,700, 600, 500, 4[...]
-
Page 102
96 Imprinter ( Endorser ) : With imprinter option (Reverse side, minimum left margin printing position of 42 mm) 1 Maximum number of characters to be printed: 40 charac ters Counter display range: 0 to 65535 (at 5 digits display) 0 to 16777215 (at 8 digits display) Direction(Printing): Top to Bottom, Bottom to Top Interface: SCSI -II Job control: E[...]
-
Page 103
97 Product: fi - 4750C Type: Desktop Image sensor: LED(RGB) + Reduced optical system Operating method: Document fixed Flat bed , Automatic Document Feed (ADF), simultaneous double - sided reading Long page scanning (297mm × 1387mm) Light source : LED (R, G, B) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 800,700, 600, 500, 400[...]
-
Page 104
98 Gamma pattern: 3 internal types (can be downloaded) Image processing function: Simplified Dynamic Threshold ( SDTC) , Edge emphasis, Edge extraction, De - Screen, SEE(Selectable Edge E nhancement), Reverse image With image processing option Dynamic Threshold ( DTC), Smoothing, Filtering, Noise remov al , Automatic Separation Imprinter ( Endorser[...]
-
Page 105
99 Product: M4099D ( fi - 4990) Type: Desktop Image sensor: R educed optical system Operating method: Automatic Document Feed (ADF), simultaneous double - sided reading Long page scanning (297mm × 878mm) Light source: Fluorescent tube ( White ) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 240, 200 dpi Output resoluti[...]
-
Page 106
100 Imprinter ( Endorser ) : With endorser option (Reverse side, minimum left margin printing position of 20 mm) 1 Maximum number of characters to be printed: 30 characters Counter display range: 0 to 65535 (at 5 digits display) 0 to 167 77215 (at 8 digits display) (There is partly limitations by the revision of the scanner device.) Direction(Print[...]
-
Page 107
101 Product: fi - 4990C Type: Desktop Image sensor: Redu ced optical system Operating method: Automatic Document Feed (ADF), simultaneous double - sided reading Long page scanning (297mm × 878mm) Light source: Fluorescent tube ( White ) Basic resolution: Horizontal scanning: 400 dpi Vertical scanning: 400, 300, 200 dpi Output resolution: Monochrom[...]
-
Page 108
102 (Ther e is partly limitations by the revision of the scanner device.) Direction(Printing): Top to Bottom Interface: SCSI -II (Wide SCSI) Online offset adjustment: Enabled Job control: Enabled Automatic de skew: Enabled Automatic Paper Size detection: Enable Black /White background switching: Enable Drop out: Enabled Double feed detection: Enabl[...]
-
Page 109
103 Pro duct: M3091DC ( fi - 4 1 10C ) T y pe: Desktop Image sensor: Reduced optical system Operating method: Automatic Document Feed (ADF), simultaneous double - sided reading Light source: Fluorescent tube ( White ) Basic resolution: Horizontal scanning: 300 dpi Vertical sc anning: 600 dpi Output resolution 1 : 50 dpi to 600 dpi (at steps of 1dpi[...]
-
Page 110
104 Job control: Disabled Double feed detection: Disabled[...]
-
Page 111
105 Product: M3092DC (fi - 4 21 0C) T y pe: Desktop Image sensor: Reduced optical system Operating method: Document fixed Flat bed (FB) , Automatic Document Feed (ADF), simultaneous double - sided reading Light source: Fluore scent tube ( White ) Basic resolution: Horizontal scanning: 600dpi ( FB) , 300 dpi (ADF) Vertical scanning: 600 dpi Output r[...]
-
Page 112
106 Job control: Disabled Double feed detection: Disabled[...]
-
Page 113
107 9 .2 Maintenance Service This section explains briefly how you can help us to provide you with high - quality mainten ance service. Since it is practically impossible for the Fujitsu service staff to be aware of every detail of your daily scanning operation, please understand that our staff may sometimes be unable to answer your question immedi[...]
-
Page 114
108 TWAIN Scanner/Driver Utility “Scanner Utility for Microsoft® Windows®” Users Guide 32 bit version First Edition June 2001 2nd Edition August 200 1 All Rights Reserved, Copyright FUJITSU LIMITED 200 1 • The contents of this document may change for improvements without prior notice. • Fujitsu takes no responsibilities for infringeme[...]