Go to page of
Similar user manuals
-
Air Conditioner
Fujitsu AUU18RC
19 pages 0.71 mb -
Air Conditioner
Fujitsu AOU18RLXFZ
8 pages 0.9 mb -
Air Conditioner
Fujitsu AOU9RL2
22 pages 6.19 mb -
Air conditioner
Fujitsu ASYG 7
21 pages 1.84 mb -
Air conditioner
Fujitsu ARYA 36 LB LC
13 pages 0.75 mb -
Air Conditioner
Fujitsu AOU36RC
19 pages 0.71 mb -
Air Conditioner
Fujitsu RO-36FA
27 pages 6.34 mb -
Air Conditioner
Fujitsu RY-36UA
27 pages 6.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu ASU30CLX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu ASU30CLX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fujitsu ASU30CLX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fujitsu ASU30CLX should contain:
- informations concerning technical data of Fujitsu ASU30CLX
- name of the manufacturer and a year of construction of the Fujitsu ASU30CLX item
- rules of operation, control and maintenance of the Fujitsu ASU30CLX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu ASU30CLX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu ASU30CLX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu ASU30CLX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu ASU30CLX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . . 4 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . 5 ERROR CONTENTS . . . . . . . . . . . . . . . . 6 INDOOR PCB CIRCUIT DIAGRAM . . . . [...]
-
Page 2
1 2006.01.31 SPECIFICATIONS INDOOR UNIT ASU30CLX ASU36CLX OUTDOOR UNIT AOU30CLX AOU36CLX COOLING CAPACITY 30,700 BTU/hr 33,100 BTU/hr POWER SOURCE 208 V / 230 V 208 V / 230 V FREQUENCY 60 Hz 60 Hz RUNNING CURRENT 15.2 A 17.7 A INPUT WATTS 3,460 W 4,040 W SEER 15.0 15.0 MOISTURE REMOVAL 9.7 Pts/hr (4.6 L/hr) 10.1 Pts/hr (4.8 L/hr) AIR CIRCULATION-Hi[...]
-
Page 3
2006.01.31 OUTLINE AND DIMENSIONS Unit : inch (mm) INDOOR UNIT Model : ASU30CLX, ASU36CLX 2 39-1/4" (998) 9" (228) 12-5/8" (320)[...]
-
Page 4
Unit : inch (mm) OUTDOOR UNIT Models : AOU30CLX, AOU36CLX 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2006.01.31[...]
-
Page 5
REFRIGERANT SYSTEM DIAGRAM 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Cooling ASU30CLX / AOU30CLX ASU36CLX / AOU36CLX Models : Refrigerant pipe diameter Liquid : 3/8" (9.52 mm) Gas : 5/8" (15.8[...]
-
Page 6
CIRCUIT DIAGRAM 2006.01.31 5[...]
-
Page 7
CN1 1 B07B-9ASK CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 CN6 5P-SAN CN2 SJH20-05WS CN5 SJH20-06WS CN8 B06B-P ASK CN10 B06B-XARK CN3 2P-SCN CN1 2P-SAN CN13 B5P-SHF-1AA 1 2 1 2 1 2 3 4 5 CN3-1 BLACK CN[...]
-
Page 8
5V V A6 470V <TNR> R106 1.0K </2W>8 TM2 (3) D14 DAN202K Q1 1 DTC124EUA 1 2 3 3 2 1 2 3 1 Q10 DTC124EUA C54 0.01 <B> R1 14 390 <1/10W> 10 5 4 3 2 1 14 18 8 27 6 5 4 I C26-14 I C26-10 3 2 1 I C1-6 I C1-47 I C1-46 R105 10K <1/10W> 5V C50 0.01 <B> (95) R103 390 <1/10W> 280V 5V (90) I C27 PS2501L-1 <KD / KE&g[...]
-
Page 9
CN201 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261R 5V D201 SLR-325 D203 SLR-325 D202 SLR-325 5 4 6 1 2 3 7 2 1 3 VCC OUT GND INDICA TOR PCB ASSY K05CY -0500HSE-D0 Models : ASU30CLX ASU36CLX 2006.02.10 8[...]
-
Page 10
TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 CAP ACITOR PCB ASSY K05FB-0500HUE-P0 ACTPM CONTROLLER PCB ASSY AOU30CLX : K05CU-0503HUE-C1 AOU36CLX : K05CU-0504HUE-C1 POWER SUPPL Y PCB ASSY K05CW-0503HUE-FL0 INVERTER ASSEMBL Y AOU30CLX : EZ-00502HUE AOU36CLX : EZ-00503HUE Models : AOU30CLX AOU36CLX 2006.02.10 O U T D O O R P R I N T E D C I R C U I T B O A[...]
-
Page 11
C64 10K <1/10W> C64 10K <1/10W> 2006.02.10 CONTROLLER PCB ASSY AOU30CLX : K05CU-0503HUE-C1 AOU36CLX : K05CU-0504HUE-C1 Models : AOU30CLX AOU36CLX 10[...]
-
Page 12
2006.02.10 TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 Models : AOU30CLX AOU36CLX 11[...]
-
Page 13
POWER SUPPL Y PCB K05CW-0503HUE-FL0 2006.02.10 Models : AOU30CLX AOU36CLX 12[...]
-
Page 14
B B W13 VIOLET W12 WHITE R200 220K <2W> C200 C201 C202 C203 + + + + 660 / 450V x 4 SMOOTHING CIRCUIT B B W8 BLUE W7 YELLOW 2006.02.10 CAP ACIT OR PCB ASSEMBL Y K05FB-0500HUE-P0 Models : AOU30CLX AOU36CLX 13[...]
-
Page 15
ERROR CONTENTS Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oeration Serial signal (forward) error, at operation start up Serial signal (forward) error, during operation Indoor unit thermistor error 2 flash 8 flash [...]
-
Page 16
4 2 2 4 6 1 5 5 2006.02.10 15 DISASSEMBLY ILLUSTRATION Models : ASU30CLX , ASU36CLX[...]
-
Page 17
2006.02.0 7 16 Models : ASU30CLX, ASU36CLX 33 29 30 8 9 31 27 28 35 36 34 28 32[...]
-
Page 18
10 10 10 10 10 10 10 10 10 10 10 10 26 10 23 22 10 Models : ASU30CLX, ASU36CLX 2006.02.10 17[...]
-
Page 19
2006.02.07 Models : ASU30CLX, ASU36CLX 18[...]
-
Page 20
2006.02.07 19 Models : AOU30CLX AOU36CLX[...]
-
Page 21
2006.02.02 20[...]
-
Page 22
2006.02.07 21[...]
-
Page 23
2006.02.07 22[...]
-
Page 24
2006.02.07 23 When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. INDOOR UNIT PARTS LIST Ref. No. Description Part No. ASU30CLX ASU36CLX Ord. Q'ty 1 FRONT PANEL TOTAL ASSY 9315335036 9315335036 2 INTAKE GRILLE ASSY 9315336026 9315336026 4 AIR FILTER 9315014016 9315014016 [...]
-
Page 25
OUTDOOR UNIT Ref. Ord. No. AOU30CLX AOU36CLX Q'ty 1 TOP PANEL SUB ASSY 9374417032 9374417032 2 FRONT PANEL M 9374094066 9374094066 3 FAN GUARD 9374330010 9374330010 4 GRIP SIDE 9374173013 9374173013 5 SERVICE PANEL SA 9374415052 9374415052 6 RIGHT PANEL 9374095148 9374095148 7 EMBLEM-REAR 9351355005 9351355005 8 PROPELLER FAN ASSY 9366378020 9[...]
-
Page 26
9305642045 Remote control unit holder Name and Shape Part No. 9315023018 9315027160 0600185534 0700076046 9310519004 9312153060 9311925071 Remote control unit Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket STANDARD ACCESSORIES 9301102000 Tapping screw (small) 0700019036 Air cleaning filter Air cleaning filter frame 2006.02.07 2[...]
-
Page 27
0512G2975[...]