Go to page of
Similar user manuals
-
Air Conditioner
Fujitsu P/N9359944058
18 pages 0.58 mb -
Air conditioner
Fujitsu ASYG 07 LL
6 pages 0.54 mb -
Air Conditioner
Fujitsu 9332280012-02
20 pages 2.05 mb -
Air Conditioner
Fujitsu ASU12CQ
18 pages 3.55 mb -
Air conditioner
Fujitsu ASYG 24LF
22 pages 0.91 mb -
Air Conditioner
Fujitsu AOU15RLQ
20 pages 0.59 mb -
Air conditioner
Fujitsu ABY 45 LB-LC
19 pages 0.89 mb -
Air Conditioner
Fujitsu AOVG12LLCA
6 pages 0.59 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu ASYA24LCC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu ASYA24LCC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fujitsu ASYA24LCC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fujitsu ASYA24LCC should contain:
- informations concerning technical data of Fujitsu ASYA24LCC
- name of the manufacturer and a year of construction of the Fujitsu ASYA24LCC item
- rules of operation, control and maintenance of the Fujitsu ASYA24LCC item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu ASYA24LCC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu ASYA24LCC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu ASYA24LCC.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu ASYA24LCC item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . . 3 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . 4 ERROR CONTENTS . . . . . . . . . . . . . . . . 5 INDOOR PCB CIRCUIT DIAGRAM . . . . . 8 [...]
-
Page 2
1 2006.03.22 SPECIFICATIONS INDOOR UNIT ASYA24LCC OUTDOOR UNIT AOYR24LCC COOLING CAPACITY 7.10 kW HEATING CAPACITY 8.10 kW POWER SOURCE 230 V FREQUENCY 50Hz RUNNING CURRENT COOLING 9.7 A HEATING 9.8 A INPUT WATTS COOLING 2,21 kW HEATING HEATING 2,24 kW E.E.R. COP 3.21 kW 3.62 kW MOISTURE REMOVAL 3.0 L/hr AIR CIRCULATION -High 1,100 m 3 /hr ELECTRIC[...]
-
Page 3
315 66 790 540 508 20 125 320 48 347 578 10 OUTLINE AND DIMENSIONS Unit : mm OUTDOOR UNIT INDOOR UNIT 998 228 320 2 2006.06.26[...]
-
Page 4
REFRIGERANT SYSTEM DIAGRAM 2-Way valve Strainer Strainer Strainer 3-Way valve Muffler 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Cooling Heating Models : ASYA24LCC / AOYR24LCC Refrigerant pipe diameter Liquid : 1/4" (6.35 mm) Gas : 5/8" (15.88 mm) 3 2006.02.28[...]
-
Page 5
CIRCUIT DIAGRAM 4 2006.02.28 INDOOR UNIT OUTDOOR UNIT[...]
-
Page 6
CN1 1 B07B-9ASK CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 CN6 B05B-XASK CN2 SJH20-05WS CN5 SJH20-06WS CN8 B06B-P ASK CN10 B06B-XARK CN3 2P-SCN CN14 B2B-XH CN16 B3B-XH CN1 2P-SAN CN13 B5P-SHF-1AA 1[...]
-
Page 7
5V V A6 470V <TNR> R106 1.0K </2W>8 TM2 (3) D14 DAN202K Q1 1 DTC124EUA 1 2 3 3 2 1 2 3 1 Q10 DTC124EUA C54 0.01 <B> R1 14 390 <1/10W> 10 5 4 3 2 1 14 18 8 27 6 5 4 I C26-14 I C26-10 3 2 1 I C1-6 I C1-47 I C1-46 R105 10K <1/10W> 5V C50 0.01 <B> (95) R103 390 <1/10W> 280V 5V (90) I C27 PS2501L-1 <KD / KE&g[...]
-
Page 8
CN201 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261R 5V D201 SLR-325 D203 SLR-325 D202 SLR-325 5 4 6 1 2 3 7 2 1 3 VCC OUT GND INDICA T OR PCB ASSY K05CY -0500HSE-D0 Model : ASY A24LCC 7 2006.02.28[...]
-
Page 9
UL1007 AWG24 RED TM101 TM102 W16 D100 D25XB60 + B W17 B B B B B B B B B B B B B B B W3 W18 B W17 W19 W20 W9 W21 EARTH CN100 W28 W29 TM301 TM302 B B W12 W13 W307 W306 + L1 L2 P N1 N2 I O CHOKE COIL L = 0.3MH 30A TM600 TM601 B W4 COMPRESSOR EMI FIL TER EMI FIL TER W1 W2 F200 TLC 25A - 250V , B EMI FIL TER EMI FIL TER N L 3 2 1 UL1015 AWG14 WHITE UL10[...]
-
Page 10
C64 10K <1/10W> C64 10K <1/10W> CONTROLLER PCB ASSY K05CU-0500HUE-C1 Model : AOYR24LCC 9 2006.02.28[...]
-
Page 11
POWER SUPPL Y PCB K05CW-0500HUE-FL0 Model : AOYR24LCC 10 2006.02.28[...]
-
Page 12
TR PCB ASSY ( I P M ) K05CZ-0500HUE-TR0 Model : AOYR24LCC 11 2006.02.28[...]
-
Page 13
C202 660/ 450V R200 220K <2W> B B B B W13 VIOLET W12 WHITE BLUE YELLOW + C201 660/ 450V C200 660/ 450V + + POWER_G B B N P W7 YELLOW W8 BLUE SMOOTHING CIRCUIT CAP ACITOR PCB ASSY K05DG-0500HUE-P0 Model : AOYR24LCC 12 2006.02.28[...]
-
Page 14
ERROR CONTENTS Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oeration Serial signal (forward) error, at operation start up Serial signal (forward) error, during operation Indoor unit thermistor error 2 flash 8 flash [...]
-
Page 15
4 2 2 4 6 1 5 5 2006.02.28 14 DISASSEMBLY ILLUSTRATION Model : ASYA24LCC[...]
-
Page 16
2006.02.28 15 33 29 30 8 9 31 27 35 36 34 28 32 Model : ASYA24LCC[...]
-
Page 17
26 23 22 2006.03.22 16 Model : ASYA24LCC 10[...]
-
Page 18
52 42 16 40 47 48 49 55 53 41 39 37 38 Model : ASYA24LCC 17 2006.02.28[...]
-
Page 19
1 7 18 5 10 20 24 32 13 12 6 39 3 35 22 21 14 36 37 11 4 34 8 16 Model : AOYR24LCC 18 2006.03.22 38 50 53 54 51 52 33[...]
-
Page 20
25 Model : AOYR24LCC 19 2006.03.22 42 40 44 43 41 55 46 45[...]
-
Page 21
1 Front Panel Total Assy 9315335012 2 Intake Grille Assy 9315336019 4 Air Filter 9315014016 5 Clamper Grille 9306755010 6 Receiver Window 9315010018 8 Crossflow Fan Assy 9315024015 9 Bearing C Assy 9306628017 10 Casing Assy 9315331014 22 R and L Louver 9311997016 23 Spacer B 9312441013 26 Drain Cap 9367677009 27 Evaporator Assy 9315347015 28 Evapor[...]
-
Page 22
OUTDOOR UNIT AOYR24LCC Ref No. Parts No. Description 11 9900056018 Pulse Motor Valve 10 9900163013 4-Way Valve 44 9703457012 ACTPM 14 313728262708 Thermistor Spring A 20 9315296023 Base Assy 33 9703516108 Outdoor Temp. Thermistor 38 9704219091 Discharge Thermistor 37 9704220059 Heat Exchanger Thermistor 40 9707121056 Inverter PCB Assy 41 9707128055[...]
-
Page 23
9305642045 Remote control unit holder Name and Shape Part No. 9315023018 9315027139 0600185534 0700076046 9310519004 9312153060 9311925071 Remote control unit Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket STANDARD ACCESSORIES 9301102000 Tapping screw (small) 0700019036 Air cleaning filter Drain pipe 9368568009 Air cleaning fil[...]
-
Page 24
0512G2974[...]