Fujitsu C120-E361-04EN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu C120-E361-04EN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu C120-E361-04EN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Fujitsu C120-E361-04EN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Fujitsu C120-E361-04EN should contain:
- informations concerning technical data of Fujitsu C120-E361-04EN
- name of the manufacturer and a year of construction of the Fujitsu C120-E361-04EN item
- rules of operation, control and maintenance of the Fujitsu C120-E361-04EN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu C120-E361-04EN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu C120-E361-04EN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu C120-E361-04EN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu C120-E361-04EN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    [...]

  • Page 2

    [...]

  • Page 3

    C120-E361-04EN SP ARC ® Enterprise M4000/M5000/M8000/M9000 Server RCI Build Procedure[...]

  • Page 4

    [...]

  • Page 5

    C120-E361-04EN ABOUT THIS PRODUCT This product is designed and manufactured for use in standard applications such as office work, personal device, househol d appliance, and general industrial applications. This product is not intended fo r use in nuclear- reactor control systems, aeronautical and space systems, air traf fi c control systems, mass t[...]

  • Page 6

    [...]

  • Page 7

    C120-E361-04EN i Preface 1 This manual explains the RCI build procedure of the SP ARC Enterprise M 4000/M5000/M8000/M9000 server . This manual is intended for authorized service personnel who perform mainte nance work of the server or field engineers. In this manual, the verification of the standalone operation of the server is assumed to have been[...]

  • Page 8

    ii C120-E361-04EN Preface SP ARC Enterprise Mx000 Servers Documentation The manuals li sted below are provided for reference. (a) Manuals on the W eb The latest versions of all t he SP ARC Enterprise Series manua ls are available at the follo wing websites: Global Site http://www .fujitsu.com/s parcenterpr ise/manual/ Japanese Site http://primeserv[...]

  • Page 9

    C120-E361-04EN iii Preface (b) Documentation CD For the Documentation CD, please contact your local sales represen tative. - SP ARC Enterprise M4000/M5000 Serv ers Documentation CD (C120-E365) - SP ARC Enterprise M8000/M9000 Serv ers Documentation CD (C120-E364) . (c) Manual included on the Enhanced Support Facility x.x CD-ROM disk Remote maintenan[...]

  • Page 10

    iv C120-E361-04EN Preface Prompt Notations The notation used for prompts in th is manual is shown below .Syntax of the Command Line Interface (CLI) Synt ax of the Command Line Interface (CLI) The command syntax is described below . Command synt ax The command syntax is as follows: z A variable that requires inp ut of a value is enclosed in < >[...]

  • Page 11

    C120-E361-04EN v Reader's Comment Form Reader's Comment Form[...]

  • Page 12

    vi C120-E361-04EN Reader's Comment Form FOLD AND T APE FOLD AND T APE BUSINESS REPLY MAIL FIRST -CLASS MAIL PERMIT NO 74 1 SUNNYV ALE CA NO POST AGE NECESSAR Y IF MAILED IN THE UNITED ST ATES POST AGE WILL BE P AID BY ADDRESSEE FUJITSU COMPUTER SYST EMS AT T E N T I O N ENGINEERING OPS M/S 249 1250 EAST ARQUES A VENUE P O BOX 3470 SUNNYV ALE C[...]

  • Page 13

    C120-E361-04EN vii Content s Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Reader's Comment Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v CHAPTER 1RCI Build Procedure . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 14

    viii C120-E361-04EN Conten ts[...]

  • Page 15

    C120-E361-04EN ix Contents Figures Figure 1.1 Basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Figure 1.2 Cluster configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Figure 1.3 Duplicated configuration . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 16

    x C120-E361-04EN Conten ts[...]

  • Page 17

    C120-E361-04EN xi Contents T ables Table 1.1 Command list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Table A.1The Error Status Code and Exp lanation . . . . . . . . . . . . . . . . . . . . . . . . . . A-1[...]

  • Page 18

    [...]

  • Page 19

    C120-E361-04EN 1-1 CHAPTER 1 RCI Build Procedure This chapter explains the following items regarding the initial build procedure of the Remote Cabinet Interface (RCI) in the installation work. - RCI Overview - RCI command - RCI Setup 1.1 RCI Overview RCI is an interface to connect RCI Host (general name for ma in units supporting RCI and for RCI I/[...]

  • Page 20

    1-2 C120-E361-04EN CHAPTER 1 RCI Build Procedure Figure 1.2 Cluster configuration Figure 1.3 Duplicat ed configuration Figure 1.4 Mixture of duplicated and unduplicated configurations RCI I/O unit RCI I/O unit RCI RCI RCI RCI RCI Hosts RCI Hosts RCI#0 RCI#0 RCI#0 RCI#1 RCI#0 RCI#1 RCI Hosts RCI Hosts RCI I/O unit RCI I/O unit RCI#0 RCI#0 RCI#0 RCI#[...]

  • Page 21

    C120-E361-04EN 1-3 1.2 RCI command 1.2 RCI command RCI commands are used to display RCI configuration information and set node addresses. T o connect I/O units equi pped with RCI ports, a set up using RCI commands is required in addition to the connection with RCI cables. Remarks: When you use the terminal func tion of the External power controller[...]

  • Page 22

    1-4 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3 RCI Setup This section explains the RCI setup for the following cases: z New setup for a single RCI Host and two RCI I/O units z New setup of two RCI Hosts z When an RCI I/O unit is added later z When a RCI Host is added later Remarks: Please refer to Appendix A, "T roubleshooting." whe[...]

  • Page 23

    C120-E361-04EN 1-5 1.3 RCI Setup 4 Connect the main unit and I/O units with RCI cables (see Figure 1.5 ). Connect an RCI branching conne ctor to each of the RCI por ts, and connect them with RCI cables by using a daisy-chain connection. Connect an RCI terminating resistor to the branching connector at either end of the RCI connection. Refer to Sect[...]

  • Page 24

    1-6 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.2 New setup of two RCI Host s Figure 1.6 New set up of two RCI Hosts 1 Log in to the XSCF Shell. 2 On main unit A, exec ute the setrci -c stat comm and to display the RCI status. 3 V erify that the RCI address is 000f7fff . Remarks: 000f7ff f is the defa ult value of the RCI address. If the defau[...]

  • Page 25

    C120-E361-04EN 1-7 1.3 RCI Setup 7 On main unit A, execute the setrci -c set command to make the settings of the host node. Since main unit A is the first unit, host_no is 1. 8 On main unit B, execute the setrci -c set command to make the settings of the host node. Since main unit B is the second unit, host_no is 2. 9 On main unit A, execute the se[...]

  • Page 26

    1-8 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.3 When an RCI I/O unit is added later Figure 1.7 When an RCI I/O unit is added later 1 Connect the I/O unit to be added with an RCI cable by using a daisy-chain connection (see Figure 1.7 ). Connect an RCI branching conne ctor to the RCI port, and th en connect it with an RCI cable by using a dai[...]

  • Page 27

    C120-E361-04EN 1-9 1.3 RCI Setup 1.3.4 When a RCI Host is added later Figure 1.8 When a RCI Hosts is added later 1 Log in to the XSCF Shell. 2 On main unit B, which is to be added, execute the setr ci -c stat command to display the RCI status. 3 V erify that the RCI address is 000f7fff . Remarks: 000f7ff f is the default value of th e RCI address. [...]

  • Page 28

    1-10 C120-E361-04EN CHAPTER 1 RCI Build Procedure 7 Execute the setrci -c addconfig comm and on main unit B to expand the RCI configuration. 8 Display the RCI status by executing the setrci -c stat command on main unit A. 9 V erify that the added main unit is incorporated. 1.3.5 Connection of RCI According to the following procedure, c onnect dif f[...]

  • Page 29

    C120-E361-04EN 1-1 1 1.3 RCI Setup Remarks: Up to 32 RCIs including the RC I main unit can be connected. Use the repeater function of the external power controller to extend the cable length used and to increase the number of connected RCI device. Note that the maximum RCI cable length is 150 meters. Remarks: The external pow er controller is inclu[...]

  • Page 30

    [...]

  • Page 31

    C120-E361-04EN A-1 Appendix A T roubleshooting A This appendix explains how to deal with possible prob lems during the RCI setup. z In the Case Where Setrci Command E nded Abnormally and Displayed “Operation Failed Error S tatus: XX” z In the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE A.1 In the Case Where Setrci Command [...]

  • Page 32

    A-2 C120-E361-04EN Appendix A T roubleshooting 20 Detected the duplicate RCI address in RCI I/O unit (Expansion file unit, External power controller). Pattern C 30 Detected the duplicate RCI address in RCI I/O unit (Line selector switch). Pattern F fd RCI construction cannot be co nstructed, or it was cancelled. Pattern G fe Other RCI unit is const[...]

  • Page 33

    C120-E361-04EN A-3 A.1 In the Case Where Setrci Command Ended Abnorm ally and Displayed “Operation Failed Error S tatus: XX” Remedy p attarn z Pattern A 1 Check the RCI setup procedure, the RCI address value and the connection. 1 Check the setting of the RCI address and the duplicate of the RCI address by setrci -c stat command. 2 Check whether[...]

  • Page 34

    A-4 C120-E361-04EN Appendix A T roubleshooting A.2 In the Case Where RCI S t atus of RCI Host Changes From ACTIVE to INACTIVE Remarks: When this probl em has occurred, do not replac e the XSCF unit because it is not a failure of the XSCF unit. This problem is occurred by the mistake of the RCI construction procedure and the RCI connection. t occurr[...]

  • Page 35

    [...]

  • Page 36

    Back Cover[...]