Go to page of
Similar user manuals
-
Air Conditioner
Fujitsu ASU9D
20 pages 1.18 mb -
Computer Drive
Fujitsu DX8100 S2/DX8700 S2
1066 pages 24.42 mb -
Printer
Fujitsu DL3600
196 pages 4.62 mb -
Photo Scanner
Fujitsu FI-6240Z
211 pages 17.4 mb -
Desktop
Fujitsu ESPRIMO P900
75 pages 2.02 mb -
Scanner
Fujitsu ScanPartner fi-4220C
196 pages -
Printer
Fujitsu FTP-634MCL002
7 pages 0.08 mb -
All in One Printer
Fujitsu 10V
148 pages 3.76 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu FCN-087, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu FCN-087 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Fujitsu FCN-087. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Fujitsu FCN-087 should contain:
- informations concerning technical data of Fujitsu FCN-087
- name of the manufacturer and a year of construction of the Fujitsu FCN-087 item
- rules of operation, control and maintenance of the Fujitsu FCN-087 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu FCN-087 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu FCN-087, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu FCN-087.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu FCN-087 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 2mm PITCH METRIC CONNECT ORS FOR PCB CONNECTION FCN-086 /087 SERIES n OVERVIEW Fujitsu’s 2mm hard metric connector F-P ACK-3 (FCN-086/087 series) are connectors for connecting boards developed to support high-speed transmission/high density packaging of communication equipment, conforms to IEC 917 (DIN 43355) and IEC 61076-4-101, and supports c[...]
-
Page 2
2 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change n CONFIGURA TION OF F&T 2 MM H.M. CONNECTOR 1. Basic conguration of socket/plug There are ve types of sockets: three basic types: type A (1 10 contacts), type B (125 contacts), and type C (55 contacts), and a 1 10 contact [...]
-
Page 3
3 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change The contact pins have a three-level sequence structure and can be connected/disconnected in an ac- tive state. The terminal side can support various applications with four types of length. These combi- nations allow 20 types of term[...]
-
Page 4
4 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change ?[...]
-
Page 5
FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change n TRANSMISSION CHARACTERISTICS The transmission characteristics were designed to an optimum level by repeating various transmission characteristics simulations when the structure was designed, so as to improve the transmission cha[...]
-
Page 6
FCN-086 /087 Series Compact PCI / VME 6-6 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change n ST ANDARD AND HOT SW AP P ART NUMBERS Coding Keys for Daughter Card Coding Keys for Midplane/Backplane Backplane P5 P 4 P 1 P 2 P 3 M ale P i n H ea de rs J 5 J 4 J 1 J 2 J 3 1 60.0 (6. 3 0) 3 U =1 00.0 ( 3 . 93[...]
-
Page 7
FCN-086 /087 Series Compact PCI / VME 6-7 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 5.6 mm (.055 to .220 in.) Drill hole Diameter: φ 0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): φ 0.6 ±0.05 mm (.024) n DIMENSIONS ?[...]
-
Page 8
FCN-086 /087 Series Compact PCI / VME 6-8 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 5.6 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) n DIMENSIONS [...]
-
Page 9
FCN-086 /087 Series Compact PCI / VME 6-9 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 5.6 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) n DIMENSIONS n MOUNTING HOLE LA YOUT Unit: [...]
-
Page 10
FCN-086 /087 Series Compact PCI / VME 6-10 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 5.6 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) n DIMENSIONS n MOUNTING HOLE LA YOUT Unit:[...]
-
Page 11
FCN-086 /087 Series Compact PCI / VME 6-1 1 Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 5.6 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) n DIMENSIONS n MOUNTING HOLE LA YOUT Unit[...]
-
Page 12
12 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Part Numbers DISCONTINUED, NO AL TERNA TE Parts available 90º 0.4 0 -0.1 (0.016 0 ) -0.004 1±0.1 (0.139±0.004) (16.2) [0.638] 0.4±0.05 (0.016±0.002) 10.85 (0.427) 4 x (6-1)=20 (0.787) 6.7 (0.264) 21.7±0.2 (0.854±0.008) 4±0.[...]
-
Page 13
13 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change FCN-086J095-G/MSD-BCR (bottom shield plate) Thickness: 1.4 to 2.0 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) ?[...]
-
Page 14
14 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Unit: mm (in.) Thickness: 1.4 to 2.0 mm (.055 to .220 in.) Drill hole Diameter: Ø0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): Ø0.6 ±0.05 mm (.024) SOCKET : 1 10 CONT ACTS n MOUNTING HOLE LA YOU[...]
-
Page 15
FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 2.0 mm (.055 to .220 in.) Drill hole Diameter: ∅ 0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): ∅ 0.6 ±0.05 mm (.024) SOCKET : 1 10 CONT ACTS WITHOUT KEY n ORDERING P ART [...]
-
Page 16
16 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Unit: mm (in.) Thickness: 1.4 to 2.0 mm (.055 to .220 in.) Drill hole Diameter: ∅ 0.7 ±0.025 mm (.028 in.) Through hole diameter (after plating): ∅ 0.6 ±0.05 mm (.024) ?[...]
-
Page 17
17 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change CODING KEY n DIMENSIONS n ORDERING P ART NUMBER: 8.9 (0.350) 2.2 (0.087) 5.75 (0.226) 6.55 (0.258) 2.9 (0.1 14) 7.9 (0.31 1) 3.15 (0.124) 2.35 (0.093) 6.1 (0.240) 9.2 (0.362) 2 (0.079) 3.8 (0.150) 6.75 (0.266) n ORDERING P ART NUMB[...]
-
Page 18
18 FCN-086 / 087 Series Dimensions are in millimeters (inches) www .fcai.fujitsu.com Specications subject to change Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku T okyo 141, Japan T el: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: promothq@ft.ed.fujitsu.com Web: www .fcl.fujitsu.com ?[...]