Fujitsu PRIMERGY RX100 S5 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu PRIMERGY RX100 S5, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu PRIMERGY RX100 S5 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Fujitsu PRIMERGY RX100 S5. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Fujitsu PRIMERGY RX100 S5 should contain:
- informations concerning technical data of Fujitsu PRIMERGY RX100 S5
- name of the manufacturer and a year of construction of the Fujitsu PRIMERGY RX100 S5 item
- rules of operation, control and maintenance of the Fujitsu PRIMERGY RX100 S5 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu PRIMERGY RX100 S5 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu PRIMERGY RX100 S5, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu PRIMERGY RX100 S5.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu PRIMERGY RX100 S5 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRIMERGY RX100 S5 System configurator and order-information g uide Contents Instructions Configuration diagr am Configurator 0 System software I Basic unit II Processor III Memory IV Riser Card V Graphics VI Accessible drives VII Hard disk drives VIII SCSI controller IX Disk array X Communication/Netw ork XI System M anagement Products (RemoteView)[...]

  • Page 2

    System c onfigurator and or der-information guide PRIMERGY RX 100 S5 St atus 2010-04-30 Instructions This document contains basic product and configuration information that will enable you to configure y our system via PC-/System-Architect Only these tools will ensure a fast and proper configur ation of your PRIMERGY server or yo ur complete PRIMER[...]

  • Page 3

    System c onfigurator and or der-information guide PRIMERGY RX 100 S5 St atus 2010-04-30 Configuration diagram PRIM ERGY RX100 S5 Sy stem unit ( I ) Standard Modul 1 Xeo n 3xx x / Celeron Power supply Pentium Dual Core Modul 3 Core 2 Duo Bay for 3,5"x 0,5" CSS 5.25"x0.5" Empty / ODD Modul 2 A ccessible drives ( VI ) Modul 4 Proce[...]

  • Page 4

    PRIMERGY-Softwar e Configurators and Release Lists Start PRIMER GY RX100 S5 PRIMERGY RX 100 S5 St atus 2010-04-30 SW - Configurator 32 bit wit h OEM-Software wit hout OEM-Software for PRIMERG Y Server for PRIMERG Y Server OEM-SW is bou nd to HW and VMw are-Software is not a llow ed to be orde red - VCMS Vi rtualC enter M anagemen t Server separatel[...]

  • Page 5

    PRIMERGY-Softwar e Configurators and Release Lists Start PRIMER GY RX100 S5 PRIMERGY RX 100 S5 St atus 2010-04-30 SW - Configurator EM64T wit h OEM-Software wit hout OEM-Software for PRIMERG Y Server for PRIMERG Y Server OEM-SW is bou nd to HW and For all SW produ cts please refer to the correspo ndi ng is not a llow ed to be orde red software con [...]

  • Page 6

    System configurat or and order-informat ion guide Start PRIMERGY RX100 S5 PRIMERGY RX100 S5 Stat us 2010-04-30 Section 1 I Basic u nit System un it con sisting o f: * 1U Housi ng in cludin g stand ard power su pply -Standard Power Supply Unit * Fans - Fans for Powe r Supply an d Chassis * Drives / Bays - 2 bays 3 .5" for "easy cha nge&quo[...]

  • Page 7

    System configurat or and order-informat ion guide A PRIMERGY RX100 S5 Stat us 2010-04-30 Base Un it (for 19'' racks ) with SA TA RAI D controller Base Un it (for 19'' racks ) with SA S RA ID con troller - S26361 -K1160-V101 - S26361 -K1160-V201 S26361-F3 436-E4 no TPM Disable fun ction for Trusted Pl atform Use according to i mp[...]

  • Page 8

    System configurat or and order-informat ion guide B PRIMERGY RX100 S5 Stat us 2010-04-30 Section 2 II Processor N o t e ** : T h e C P U i s n o t i n c l u d e d i n t h e b as e u n i t an d h as t o b e c o n f i g u r ed s ep ar a t el y . One of foll owing CPU´s has to be selected for an orde rable basic unit Dual-Core CPU`s - 1x 64-bit I nte[...]

  • Page 9

    System c onfigurator and or der-information guide C PRIMERGY RX 100 S5 St atus 2010-04-30 Section 6 VI Acc essible drives Setu p PRIMERGY RX100 S5 by ServerStart is su pported w ith fol low ing con figuratio ns: no DVD, no CD: remote in stallatio n on ly ( PXE service & DHCP server required ) built in DVD or USB DVD: UNC Netw ork share reach ab[...]

  • Page 10

    System c onfigurator and or der-information guide D PRIMERGY RX 100 S5 St atus 2010-04-30 Section 7 VII Hard disk drive s Every SA TA base un it is prepare d for easy ch ange SATA stan dard h ard disks. D1 An o ption for hot plu g hard d isks is possible to orde r. S2636 1-F3461-E1 60 S2 6361-F32 72-E250 S2636 1-F3272-E5 00 HD 160GB 7.2krpm 3.5&quo[...]

  • Page 11

    System c onfigurator and or der-information guide D1 PRIMERGY RX 100 S5 St atus 2010-04-30 Harddi sk Bay ho t plug 2x 3.5" Alw ays in clu ded in SAS Base Un it S2636 1-F3861-E1 60 S26361-F32 65-E250 S2636 1-F3265 -E500 HD 160GB 7.2krpm 3.5" HD 250G B 7.2krpm 3.5" HD 500GB 7.2krpm 3.5" 7200rpm,<9.0 ms, 8MB Ca che 7200rpm,<9[...]

  • Page 12

    System c onfigurator and or der-information guide F PRIMERGY RX 100 S5 St atus 2010-04-30 Section 8 VIII SCSI/SA S-Controller SCSI/SA S-Controller Low Profile Sl o t s u i t ab l e f o r St an dar d /L ow P r o f i l e PCIe o n l y 1x p er Sy st em 2 slots PCIe x8 ( w ired x8 ) avai lable SCSI-controller for external drives and periphera l devices [...]

  • Page 13

    System c onfigurator and or der-information guide G PRIMERGY RX 100 S5 St atus 2010-04-30 Sections 9 IX Disk Array On board Hot Plug / Easy Chan ge The system is equ ipped with a 4-ch SAS on-b oard controller and emb edded "IME". SATA RAID Co ntroller I ME (In tegrated Mirrori ng Enh an ced) offers the RAID l evels 0, 1, 1E w ithou t an y[...]

  • Page 14

    Sy stem configurato r and orde r-information guide H PRIMERGY RX100 S5 Statu s 2010-04 -30 Section # X Communication / Network Dual Gi gabit Ethernet Contr. Teaming: Failover, Load Balancing onboard The Intel LAN Control lers 1000GT, 1000MF, 1000PT, 1000PF Broadcom BDC57 15C can be used with the on-boar d controller i n Teaming Mode ext: 2x RJ 45 c[...]

  • Page 15

    System c onfigurator and or der-information guide I PRIMERGY RX 100 S5 St atus 2010-04-30 Section # XI System Manag ement Products (RemoteView) S2636 1-F1790-E2 41 iRM C S2 (inte grated Remote Man agemen t Controll er) onbo ard server managemen t iRMC S2 advan ced pack control ler wi th dedi cated 10/10 0 Service LAN-po rt and in tegrated graph ics[...]

  • Page 16

    System con figurator and order-inform ation gu ide PRIMERGY RX 100 S5 Sta tus 2010 -04-30 Change Report Date Order number Changes 2009-09-30 S26361-F38 70-E516 4GB Memory available on special release 2009-07-31 S26361-F34 76-E760 Core2 Duo E760 0 - now a vailable 2009-07-31 S26361-F34 76-E630 Core2 Duo E630 0 - now a vailable 2009-03-31 S26361-F32 [...]