Fujitsu PRIMERGY TX150 S4 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu PRIMERGY TX150 S4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu PRIMERGY TX150 S4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Fujitsu PRIMERGY TX150 S4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Fujitsu PRIMERGY TX150 S4 should contain:
- informations concerning technical data of Fujitsu PRIMERGY TX150 S4
- name of the manufacturer and a year of construction of the Fujitsu PRIMERGY TX150 S4 item
- rules of operation, control and maintenance of the Fujitsu PRIMERGY TX150 S4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu PRIMERGY TX150 S4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu PRIMERGY TX150 S4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu PRIMERGY TX150 S4.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu PRIMERGY TX150 S4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRIMERGY TX 150 S4 System configurator and order-information guide Contents Instructions Configuration diagram Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI Controller VIII Disk array IX Communication/Network X System management options XI Miscellaneous XII Country s[...]

  • Page 2

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/ System-Architect. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Ra[...]

  • Page 3

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Configuration diagram PRIMERGY TX150 S4 System unit ( I ) SIDE VIEW FRONT VIEW 3 x 5.25" or PS (I) 5.25" x 1.6" 1. PSU 2. PSU Redundant power supply option 5.25" x 1.6" Modul 1 Pentium 4 Modul 3 Modul 2 Accessible drives ( V ) Modul 4 Proces[...]

  • Page 4

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator IA32 with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system VMware-Software software is not allowed, - VCMS VirtualCenter Management Server apart from few VMware - GSX [...]

  • Page 5

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator EM64T with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system software is not allowed, apart from few VMware add-ons For all SW products please refer to the correspondin[...]

  • Page 6

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 Section I Basic unit System unit consisting of: * Housing including standard power supply (no redundancy) * Sliding screen with lock (only for floorstand version) Systemboard with: * 7 PCI slots: 1x PCIe x 1 1x PCIe x 4 (x8 Slot) 1x PCI-X 66 [...]

  • Page 7

    System configurator and order-information guide A PRIMERGY TX150 S4 Status 25.11.2005 Floorstand version SCSI basic unit 19" Rack version SCSI basic unit (5 U) Pentium 4 processor, memory Pentium 4 processor, memory PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V136 PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V336 PD 820 2.8GHz/800MHz/2x1MB 1G[...]

  • Page 8

    System configurator and order-information guide B1 B2 PRIMERGY TX150 S4 Status 25.11.2005 PRIMERGY Floorstand PRIMERGY Rack PRIMECENTER- Rack SNP:SY-F1647E301-P "rack-mounting ex factory" Installation ex works for one This service is to be ordered once server or subsystem per installable server/storage Hereby the rack will be delivered su[...]

  • Page 9

    System configurator and order-information guide C PRIMERGY TX150 S4 Status 25.11.2005 Section II Processor Section III Memory There are 2 memory banks with 2 DIMM slots each. Single channel memory configuration allow maximum flexibility: Additional memory can be configured as single memory modules. Dual channel memory configurations for maximum per[...]

  • Page 10

    System configurator and order-information guide D PRIMERGY TX150 S4 Status 25.11.2005 Section V Accessible drives There are 3x 5.25" bays for accessible drives: - 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive - 2 x 5.25" bays remaining, can be occupied by 2x accessible drives Setup TX150 S4 by ServerStart is suppo[...]

  • Page 11

    System configurator and order-information guide E PRIMERGY TX150 S4 Status 25.11.2005 S26361-F2814-E6 Backup drive and hard disk should run on separate channels 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to If internal HDD's are connected at the RAID controller separate SCSI controller (not IME/ZCR), then for[...]

  • Page 12

    System configurator and order-information guide F PRIMERGY TX150 S4 Status 25.11.2005 Section VII SCSI-Controller All internal cables and adapters are included within the basic units and components respectively Cabeling priorities: internal HDs are cabled according to following priorities. (Prio 1 - 3 ): 1.) For a configuration without any Disk Arr[...]

  • Page 13

    System configurator and order-information guide G PRIMERGY TX150 S4 Status 25.11.2005 B. SCSI controller for internal backup drives S26361-F2399-E2 SCSI 160 Controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50-pin or Ultra[...]

  • Page 14

    System configurator and order-information guide H PRIMERGY TX150 S4 Status 25.11.2005 continued on previous E. 2-Kanal Ultra 320 SCSI Controller für Disk Array page S26361-F3090-E256 2-channel RAID Controller U320 LSI 320-2x 256MB SDRAM ECC Cache 1x default with TBBU plug: internal 2x HD68; external: 2x VHDCI without cable 64/133 PCI-X controller,[...]

  • Page 15

    System configurator and order-information guide I PRIMERGY TX150 S4 Status 25.11.2005 Section IX Communication / Network Gigabit Ethernet Contr. on-board The Intel LAN controllers 1000MT can be used Broadcom with the on-board controller in Teaming Mode ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel S26361-F3053-E1 S26361-F3142-E1 Gigabit Ethe[...]

  • Page 16

    System configurator and order-information guide J PRIMERGY TX150 S4 Status 25.11.2005 Section X System management options S26361-F2425-E103 RSB S2 LP 3HU RemoteView Service Board S2 Low Profile Version with 3 U bracket for one standard PCI-slot incl. cables and RV SW max. 1x per system S26361-F2425-E305 RSB S2 LP external power supply RemoteView Se[...]

  • Page 17

    System configurator and order-information guide K PRIMERGY TX150 S4 Status 25.11.2005 Section XII Country specific / rack specific options A country specific power cord has to be ordered for all floorstand versions: - once per basic unit and an additional second cable - if an second hot plug, redundant power supply modul is ordered. PRIMERGY TX150 [...]

  • Page 18

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Cange Report Date Order number Changes 2005-11-23 S26361-F1809-E2 ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available 2005-03-31 First release Fujitsu Siemens Computers Enterprise Products - PRIMERGY Server 18 of 18[...]