Go to page of
Similar user manuals
-
Marine RADAR
Furuno 1824C-BB
236 pages 2.74 mb -
Marine RADAR
Furuno FR-2115/2125
79 pages 3.45 mb -
Marine RADAR
Furuno FR-7111
88 pages 2.49 mb -
Marine RADAR
Furuno FR-8122
129 pages 3.23 mb -
Marine RADAR
Furuno NX-300
65 pages 1.38 mb -
Marine RADAR
Furuno FAR-2167DS-BB
111 pages 4.57 mb -
Marine RADAR
Furuno 1941
95 pages 3.38 mb -
Marine RADAR
Furuno FR-1510D
110 pages 4.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Furuno FAR-2117, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Furuno FAR-2117 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Furuno FAR-2117. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Furuno FAR-2117 should contain:
- informations concerning technical data of Furuno FAR-2117
- name of the manufacturer and a year of construction of the Furuno FAR-2117 item
- rules of operation, control and maintenance of the Furuno FAR-2117 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Furuno FAR-2117 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Furuno FAR-2117, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Furuno service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Furuno FAR-2117.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Furuno FAR-2117 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
www .furuno .co .jp All brand and product names are trademarks, registered tr ademarks or ser vice marks of their respective holders. MARINE RADAR/ARP A F AR-21 17/2127/2817/2827 F AR-21 17-BB/2127-BB Installation Manual Comply with MSC.192(79) T ABLE OF CONTENTS SAFETY IINSTRUCTIONS ..................... i EQUIPMENT LISTS .........................[...]
-
Page 2
The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 A : JAN 2004 . Printed in Japan All rights reserved. K : DEC . 12, 2008 Pub. No. IME-35190-K *00014745418* *00014745418* ( HIMA ) FAR-2117/27/2817/2[...]
-
Page 3
i Mandator y Action Prohibitiv e Action W ARNING Indicates a potentially hazardous situation which, if not av oided, could result in death or serious injur y . CA UTION Indicates a potentially hazardous situation which, if not av oided, can result in minor or moderate injury . W ar ning, Caution SAFETY INSTR UCTIONS The operator and installer must [...]
-
Page 4
ii Be sure that the power supply is compatible with the voltage rating of the equipment. Do not install the monitor unit, processor unit or control unit where they may get wet from rain or water splash. Fire or damage to the equipment can result if a different cable is used. Connection of an incorrect power supply can cause fire or damage the equip[...]
-
Page 5
iii EQUIPMENT LISTS S t andard Supply Name T ype Code No. Qty Remarks XN12AF-RSB096-078 - F AR-21 17/21 17-BB/2817, 24 rpm, 1200 mm, W/CP03-24201 XN12AF-RSB097-078 - F AR-21 17/21 17-BB/2817, 42 rpm, 1200 mm, W/CP03-24201 XN20AF-RSB096-078 - F AR-21 17/21 17-BB/2817, 24 rpm, 2000 mm, W/CP03-19101 XN20AF-RSB097-078 - F AR-21 17/21 17-BB/2817, 42 rpm[...]
-
Page 6
iv Optional Equipment Name T ype Code No. Remarks Gyro Converter GC-10-2 000-080-440 See chapter 4. Performance Monitor PM-31 000-080-438 Mandatory for IMO radar RU-1803 - Converts 440 V AC to 100 V AC, for processor unit T ransformer Unit RU-3305 - Converts 1 10/1 15/220/230 V AC to 100 V AC, for de-icer RU-3424 - 1 15/230 V AC to 24 VDC, for proc[...]
-
Page 7
v OP03-28900 000-082-658 FR-FTPC-CY 10 m OP03-28910 000-082-629 FR-FTPC-CY 20 m LAN Cable Kit (with armor) OP03-28920 000-082-660 FR-FTPC-CY 30 m Modular connection MPS588-C, 2 pcs. FP03-09820 008-535-560 Hanger assy . for MU-201CR Accessories FP03-09830 008-536-020 Hanger assy . for MU-231CR Hand Grip FP03-09840 008-535-570 For monitor unit 03-163[...]
-
Page 8
vi SYSTEM CONFIGURA TION PROCESSOR UNIT RPU-013 EPFS (Navigator) IEC-61162 Serial Data (Input/Output) IEC-61162 Serial Data (Input) SDME (Speed Log) Gyrocompass AIS T rack Control Unit : Option : Doc kyard supply : Standard Rectifier R U-3424 R U-1746B-2 AD-100 MEMOR Y CARD INTERF ACE UNIT CU- 200-F AR VDR External Monitor Sub Display Alarm*** MONI[...]
-
Page 9
1-1 1. MOUNTING NO TICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solv ents that can damage coating and plastic par ts, especially plastic connectors. 1.1 Antenna Unit Mounting considerations • The antenna unit is generally inst alled either on top of the [...]
-
Page 10
1. MOUNTING 1-2 • Inst all the antenna unit away from interf ering high-power energy sources and other transmitting radio antenna. • Keep the lower edge of the antenna unit abov e the safety rail by 500 mm or more. • T wo antenna units should be mounted as below: more than 20 more than 1 m • No funnel, mast or derrick should be within t he [...]
-
Page 11
1. MOUNTING 1-3 Assembling the antenna unit The antenna unit consists of the antenna radi ator and the antenna unit chassis, and they are packed sep arately . Fasten the antenna radiat or to the antenna unit chassis as follows: 1. For the XN20AF , XN24AF , attach two guide pins to the underside of the antenna radiator . 2. Remove the waveguide cap [...]
-
Page 12
1. MOUNTING 1-4 O-ring Radiator bracket Waveguide Antenna radiator Hex bolt (M8x40), 8 pcs. (XN20AF, XN24AF) Hex. bolt (M8x35), 8 pcs. Flat washer Spring washer (XN12AF) Guide pin (XN20AF, XN24AF only) Fastening the radiator to the radiator bracket Fastening the antenna unit to the mounting plat form The antenna unit may be assembled before hoisti [...]
-
Page 13
1. MOUNTING 1-5 4. Place the antenna unit on the rubber mat, orienting the unit so the bow mark on its base is facing the ship’s bow . Ground terminal Rubber mat Bow mark Antenna unit, front view 5. Fasten the antenna unit to the mounting pl atform with M12x60 hex bolt s, nuts, flat washers and seal washers. 6. Using hex bolt (M6x25), nut (M6) an[...]
-
Page 14
1. MOUNTING 1-6 1.2 Monitor Unit The monitor unit can be flush mounted in a console panel, or mounted on a desktop using the optional accessories. Note: F AR-21 17-BB/2127-BB have no monitor unit. Prep are a suitable monitor locally . Recommended monitor: SXGA (1280x1024), aspect ratio 5:4 Mounting considerations When selecting a mounting location,[...]
-
Page 15
1. MOUNTING 1-7 570 4- φ 8 FIXING HOLES 598 (96) 505 4-FIXING HOLES 554 471 30 80 Monitor unit MU-231CR 570 ± 1 313 ± 1 (For FAR-2817/2827) 313 ± 1 ± 1 Flush mounting of monitor unit Panel hook Panel cover Fixing screw Attaching p anel hook and panel cover Note: If you need to remove the monitor unit from the mounting panel, remove the four pa[...]
-
Page 16
1. MOUNTING 1-8 Desktop mounting Use the optional accessories to m ount the monitor unit on a desktop. • For F AR-21 17/2127: FP03-09820 (Code No.: 008-535-560) • For F AR-2817/2827: FP03-09830 (Code No.: 008-536-020) Contents of FP03-09820/09830 Name T ype Code No. Qty Remarks Hanger L 03-163-1 1 1 1 100-305-141 1 Hanger R 03-163-1 1 12 100-30[...]
-
Page 17
1. MOUNTING 1-9 Panel cover Hex bolt (M6x25) Hanger (R) Hanger stay M12 bolts for fixing (Dockyard supply) Hanger (L) Hex bolt M10x30 Plastic rivet Hole plug Panel cover To remove this, insert fingernail in groove. Flat Washer M10 Spring Washer M10 Monitor Unit The hand grip is optionally availabl e for the desktop mounting monitor unit. Handle[...]
-
Page 18
1. MOUNTING 1-10 1. Desktop mounting: Fasten the fixing plates to the fixing holes with the hex head bolt s (supplied). Flush mounting: Fasten the display unit to the m ounting location, and then attach the fixing plates with four self-tapping screws. Fixing plate Fixing hole He x head bolt 2. Att ach the hood to the display unit (t he hood is outs[...]
-
Page 19
1. MOUNTING 1-1 1 Fixing with KB fixing plate 1. Fix the KB fixing plate to the bottom of the control unit. 2. Attach cushions (three for RCU-014, two for RCU-015/016) to the bottom of the control unit as shown below . 3. Fix it to a desired location with self-tapping screws (local supply). Cushion KB fixing plate Side view for RCU-014/015/016 Fixi[...]
-
Page 20
1. MOUNTING 1-12 Flush mounting Use the optional flush mount kit FP03-09870 to mount the control unit RCU-014, RCU-015 and/or RCU016 to a console panel. Name: Flush mount kit T ype: FP03-09870 Code No.: 008-535-630 No. Name T ype Code No. Qty 1 Mount plate 03-163-7531 100-306-261 4 2 Hex nut M5 000-863-108 4 3 Wing screw M5x40 000-162-682-10 4 4 Pa[...]
-
Page 21
1. MOUNTING 1-13 T o connect RCU-016 in series with RCU-014 1. Pass the cable derived from RCU-016. 2. Connect the connector of the cable to J502. 3. Clamp the copper part of the cable with the cable clamp. Inside of RCU-014[...]
-
Page 22
1. MOUNTING 1-14 T o change the cable entry T o change the cable entry from the side (default) to the bottom, modify the unit as shown below . Cable clamp 03-163-7804 J524 J521 Screw M3x8 Screw M4x8 2. Pull out the cable . 1. Remov e the cable clamp . 3. P ass the cable from this hole . 4. In here, clamp the copper par t of the cable with the cab l[...]
-
Page 23
1. MOUNTING 1-15 1.4 Processor Unit Mounting considerations When selecting a mounting location, keep in mind the following points: • Locate the processor unit away from heat sources because of heat that can build up inside the cabinet. • Locate the equipment away from places subject to water splash and rain. • Leave suf ficient sp ace at the [...]
-
Page 24
1. MOUNTING 1-16 This page is intentionally lef t blank.[...]
-
Page 25
2-1 2. WIRING Wiring consideration • T o lessen the chance of picking up electrical interference, avoid where possible routing the signal cable near other onboard electric al equipment (radars, transmitting radio antennas, etc.) Also avoid running the cable in parallel with power cables. When crossing with other cable, the angle should be 90 ° t[...]
-
Page 26
2. WIRING 2-2 2.2 Antenna Unit NOTE T ransceiver module (magnetron inside) Height more than 5 cm Non-ferrous block The magnetron in the transceiver module will de- magnetize if it contacts ferrous material. When dismounting the transceiver module, lay it on its side or on top of non-ferrous material as shown below . 1. Open the rear cover of the an[...]
-
Page 27
2. WIRING 2-3 Antenna unit, front view , cover removed 6. Fabricate the signal cable RW -9600 as shown below . a) Remove the outer vinyl sheath, by about 500 mm, then armor and inner sheath by about 470mm. b) Unravel the shield to expose the core wires. c) T rim each core wire (except coaxial wire) considering its location on the terminal board. d)[...]
-
Page 28
2. WIRING 2-4 8. Nip the armor between two washers, and trim the excess armor from around washers. And then pass the shield between the clamping ring and the washer as shown below . Fasten the clamping ring with the screws. 4-M4x16 Shield Rubber gasket (25B) Washer Clamping ring Armor Signal cable entrance 9. Connect the signal cable to the termina[...]
-
Page 29
2. WIRING 2-5 11. Set the transceiver module to the antenna unit, push it in until it stops, and then tighten fixing bolts (4 pcs.). Connect plugs P823, P803, P831, P921 and J91 1 (if installed). Fasten the shield wire to the wing nut on the transceiver module. CA UTION Push in transceiver unit until it stops. Failure to do so may cause leakage of [...]
-
Page 30
2. WIRING 2-6 2.3 Monitor Unit T wo cables are terminated at the display unit: the signal cable from the processor unit (5 m or 10 m cable) and the power cable from the ship’s mains. The signal cable comes with a connector preattached to it for connection to the monitor unit. Fabricate the power cable as below . Use DPYC-2.5 (Japan Industry S tan[...]
-
Page 31
2. WIRING 2-7 2.4 Processor Unit Four cables are terminated at the processor unit: the antenna unit cable, display unit cable, control unit cable and the power cable. Cables other than the power cable come with a connector preattached to them for connection to the processor unit. Fabricate the power cable as below . For the power cable, use DPYC-2.[...]
-
Page 32
2. WIRING 2-8 Connection of cables The power cable is connected to the terminal board on the rear panel and the signal cable from the monitor unit is connected to the DVI-D connector . Other cables are connected to the printed circuit board 03P9342. F1 1 2 ACK φ 18.9 AIS 17 AD100 8 GYRO 28 PSU004 24 φ 7.4 VDR IN φ 7 VDR OUT 24’ 26 9 14 17 15 D[...]
-
Page 33
2. WIRING 2-9 Location of connectors Open the processor unit as follows and the 03P9342 board appears. J621 J620 J619 J618 J612 J610 J608 J607 J606 J605 J604 J603 J602 J601 J617 J616 PSU External alarm J654 J615 J614 J613 Tx HV line J609 Cable clamp 03P9342 Gyro converter board or AD-100 Speed log Navigator Heading sensor Cable from the control uni[...]
-
Page 34
2. WIRING 2-10 Cable fabrication for the cables connected to the 03P9342 board x Signal cable RW -9600 (Between antenna unit and processor unit) Shield Armor Clamp here by cable clamp. Vinyl tape After exposing cores, wind shield around the armor . Vinyl sheath Coaxial cable 6 60 450 5 Conductor 59 Coaxial cable 14 Fold back shield. x Other c[...]
-
Page 35
2. WIRING 2-1 1 Connection of Sub-display A conventional remote display and/or F AR-2107 series radar can be connected to J617 and J618 in the processor unit as a sub-display . However , the control for GAIN and STC are different depending on J617 and J618. Refer to the t able to connect sub-displays. Port Conventional remote display F AR-2107 seri[...]
-
Page 36
2. WIRING 2-12 2.5 Changing AC Power Specification of Processor Unit To change AC power specification between 100 VAC and 220 VAC, add or remove jumper connector P108 on the PWR board 03P9339 and change the fuse on the processor unit according to ship’s mains as shown in the table below. The figures below and on the next page show the location of[...]
-
Page 37
2. WIRING 2-13 J104 J103 J106 J105 J101 PWR board (P)HV AC FIL P108/J108 R21 (OVER) 8 7 6 5 4 3 2 1 Jumper connector (VH8P) How to adjust the overvolt age detection circuit: 1. Add or remove the jumper connector P108 and change the fuse. 2. Rotate R21 fully clockwise on the PWR board. 3. Connect a variable transformer between ship's mains and [...]
-
Page 38
2. WIRING 2-14 This page is intentionally lef t blank.[...]
-
Page 39
3-1 3. SETTING AND ADJUSTMENT 3.1 DIP Switch Setting The processor unit is shipped for model F AR-21 17 or F AR-2127. If your model is F AR-2817/ 2827/21 17-BB/2127-BB, change the DIP switch setting as follows. 1. Remove the top cover of the processor unit. 2. Open the SPU assembly block. Shield cover SPU assembly block SPU board 03P9337 DIP switch[...]
-
Page 40
3. SETTING AND ADJUSTMENT 3-2 [ECHO] 1 BACK 2 2ND ECHO REJ OFF /ON 3 TUNE INITIALIZE 4 PM OFF /ON 5 SART OFF /ON 6 WIPER OFF /1/2 7 ECHO AREA* CIRCLE/WIDE/ALL 8 [PICTURE SELECT] 9 STC RANGE +00 3.2 Initializing T uning 1. T ransmit the radar on 48 nm range and rot ate the GAIN knob to show 70-80 of the gain bar . 2. Roll the trackball to choose the[...]
-
Page 41
3. SETTING AND ADJUSTMENT 3-3 3.3 Heading Alignment Y ou have mounted the antenna unit facing straight ahead in the direction of the bow . Therefore, a small but conspicuous target dead ahead visually should appear on the heading line (zero degrees). In practice, you will probably observe some small bearing error on the display because of the diffi[...]
-
Page 42
3. SETTING AND ADJUSTMENT 3-4 3. Read the target bearing. 4. Measure the bearing of the stationary t ar get on the navigation chart and calculate the difference between actual bearing and app arent bearing on the radar screen. 5. Press the [MENU] key to show the main menu. 6. While pressing and holding down the [HL OFF] key , press the [MENU] key f[...]
-
Page 43
3. SETTING AND ADJUSTMENT 3-5 How to Access the Installation Mode with the RCU-015 T rackball Style Controller 1. By using the trackball, move the pointer until it highlights the MENU box as shown. DO NOT CLICK the menu box, just leave the arrow over the menu. 2. Press and hold down the F1 key . Keep it held down during the next step. 3. Then , cli[...]
-
Page 44
3. SETTING AND ADJUSTMENT 3-6 3.4 Adjustment Sweep T iming Sweep timing differs with respect to the length of the signal cable between the antenna unit and the processor unit. Adjust sweep timing at installation to prevent the following symptoms: • The echo of a “straight” t arget (for example, pier), on the 0.25 m range, will appear on the d[...]
-
Page 45
3. SETTING AND ADJUSTMENT 3-7 3.5 Suppressing Main Bang If main bang appears at the screen center , suppress it as follows. 1. T ransmit the radar on a long range and then wait ten minutes. 2. Adjust gain to show a slight amount of noise on the display . 3. Select the 0.25 nm range. Adjust sea clutter control to suppress sea clutter . 4. Press [5] [...]
-
Page 46
3. SETTING AND ADJUSTMENT 3-8 3.6 Other Settings ECHO menu setting Open the ECHO ADJ menu as de scribed on page 3-3 and 3-4. [ECHO ADJ] 1 BA CK 2 CABLE A TT ADJ A UTO/MANU AL 30 3 HD ALIGN 000.0 ° 4 TIMING ADJ 0 5 MBS 0 6 DEF A UL T ANT HEIGHT 5/7.5/10/ 15 /20/ 25/30/35/40/45/ more 50 m 7 NEAR STC CUR VE 2/2.5/ 3 /3.5/4.2 8 MID STC CUR VE 3/ 4 /5/[...]
-
Page 47
3. SETTING AND ADJUSTMENT 3-9 Scanner setting 1. Open the INITIALIZE menu described on page 3-2. 2. Press [3] key to open the SCANNER menu. [SCANNER] 1 BA CK 2 BLIND SECT OR 1 ST AR T 000 ° ANGLE 000 ° 3 BLIND SECT OR 2 ST AR T 000 ° ANGLE 000 ° 4 ANT REV OLUTION LO/HI/ AU T O 5 ANT SW OFF/ ON /EXT 6 ANT ST OPPED STBY /TX 7 M SPEC OFF/ON 8 BB T[...]
-
Page 48
3. SETTING AND ADJUSTMENT 3-10 INST ALLA TION menu setting Open the INST ALLA TION menu by pre ssing [4] key on the INITIALIZE menu. [INST ALLA TION] 1 BA CK 2 RAD AR* MAIN /SUB 3 RANGE UNIT ** NM /SM/km/kyd 4 RAD AR NO*** 1 /2/3/4/5/6/7/8 5 RAD AR POSN FORE/ MAIN T OP / MAIN 2ND/MAIN 3RD/ AFT/POR T/ ST AR BOARD 6 MODEL 6/ 12 /25 UP/25 DO WN/ 50/30[...]
-
Page 49
3. SETTING AND ADJUSTMENT 3-1 1 TYPE Choose type of radar: IMO, A, B, C, or W . ON TIME and TX TIME These items show number of hours the radar has been turned on and transmitted, respectively . V alue can be changed; for example, after replacing magnetron TX T ime can be reset to 0. PM GAIN ADJ Note: If you install the Performance Monitor PM-31 at [...]
-
Page 50
3. SETTING AND ADJUSTMENT 3-12 OWN SHIP INFO menu setting Open the OWN SHIP INFO menu by pre ssing the [5] key on the INITIALIZE menu. [O WN SHIP INFO] 1 BA CK 2 LENGTH/WIDTH LENGTH 100 m WIDTH 50 m 3 SCANNER POSN BO W 0 m POR T 0 m 4 GPS1 ANT POSN BO W 0 m POR T 0 m 5 GPS2 ANT POSN BO W 0 m LEFT 0 m 6 CONNING POSN BO W 0 m POR T 0 m LENGTH/WIDTH a[...]
-
Page 51
3. SETTING AND ADJUSTMENT 3-13 TT PRESET menu setting Open the TT PRESET menu by pressing [6] key on the INITIALIZE menu. [TT PRESET] 1 BA CK 2 TT DA T A OUTPUT OFF/TTM/TTD REL/TR UE 4800/9600/ 19200/38400 3 MAX RANGE 24/32 4 ECHO LEVEL 16 5 QV DISPLA Y OFF/ON 6 TT W/O GYR O* OFF/ON 7 [TT PRESET] 8 [TRA CK PRESET] 9 [TT SENSOR D A T A] 0 DEF A UL T[...]
-
Page 52
3. SETTING AND ADJUSTMENT 3-14 TT W/O GYRO (Not on IMO radar) If a gyrocompass is not connected, choose the TT function, ON(working) or OFF (no working). LAND SIZE Set the land size in units of 100 m. The setting range is 100 to 3000 m. ANT SELECT Set the antenna radiator type of your radar . AUTO ACQ CORRE Set the correlation count of automatic ac[...]
-
Page 53
3. SETTING AND ADJUSTMENT 3-15 OTHER menu setting Open the OTHER menu by pressing [8] key on the INITIALIZE menu. [O THERS] 1B A C K 2 DEMO ECHO OFF/EG/TT -TEST/PC 3 EA V W/O GYRO OFF/ON 4 TT CA TEGOR Y SELECT CA T1/CA T2 3 5 INS OFF/SERIAL/LAN EA V w/o GYRO If a gyrocompass is not connected, choose th e echo average function, ON (working) or OFF ([...]
-
Page 54
3. SETTING AND ADJUSTMENT 3-16 3.7 Dual Radar Display (non IMO-type only) The image from both X-band and S-band radars may be shown together on one radar display. This allows you to take advantage of the best characteristics each type of radar has to offer. Two display formats are available, mixed and combine, and you may select desired format from[...]
-
Page 55
3. SETTING AND ADJUSTMENT 3-17 Note 2: In the dual radar display, a guard zone set on the main radar is also accommodated on the external radar. When the position of the antennas for the main and external radars is different and the No. 2 guard zone is se t on a close-in range, the on-screen guard zone may be shifted slightly from both the main rad[...]
-
Page 56
3. SETTING AND ADJUSTMENT 3-18 1. Push the right button four times to close the menu. Note 1 : The dual radar function becomes inoperative when the external radar is turned off, set to stand-by, or set as sub display. When this happens, the buzzer sounds and th e message "EXT RADAR STBY" (power off, stand-by only) appears. Note 2: The dua[...]
-
Page 57
3. SETTING AND ADJUSTMENT 3-19 3.7.2 S pecifying Sector Wi d th and Length When 2 DUAL RADA R in the DUAL RADAR menu is set for "COMBINE", specify the width and length o f the sector from the external radar to display on own radar. 1. Open the INITIALIZE menu. 2. Press the [3] key to show the SCANNER menu. 3. Select 9 [DUAL RADAR] and pus[...]
-
Page 58
3. SETTING AND ADJUSTMENT 3-20 7. Use the scrollwheel to set START and ANGLE, referring to the description and example below. Spin the scrollwheel to set and push it to confirm. A solid green line marks the dual radar display area. • START: Start point of the sector (in degrees, 000-359) • ANGLE: Width of the sector (in degrees, 000-359) In the[...]
-
Page 59
3. SETTING AND ADJUSTMENT 3-21 3.7.3 Choosing External Radar (image source) Select the external radar to use in the dual radar display. 1. Open the INITIALIZE menu. 2. Press the [3] key to show the SCANNER menu. 3. Select 9 [DUAL RADAR] and push the left button. 1B A C K 2 DU AL RADAR OFF/MIX/COMBINE 3 COMBINE MODE* O WN/EXT 4 COMBINE SECT OR* ST A[...]
-
Page 60
3. SETTING AND ADJUSTMENT 3-22 This page is intentionally lef t blank.[...]
-
Page 61
4-1 4. INST ALLING OPTIONAL EQUIPMENT 4.1 Gyro Converter GC-10 The Gyro Converter GC-10, incorporated inside the processor unit, converts analog gyrocompass reading into digit al coded bearing data for display on the radar screen. This section explains how to install the GC-10 (mainly consisting of the GYRO CONVERTER board) and set it up according [...]
-
Page 62
4. INST ALLING OPTIONAL EQUIPMENT 4-2 2. Fasten the GYRO CONVERTER board in the processor unit with five washer head screws and male connector 231-607/019-FUR (called J602) with two screws. Connector (231) 231-607/019-FUR 1 7 Connector (231) 231-107/026-FUR 1 1 7 7 GYRO CONVER TER board 64P1106A Screw M3x8 5 pcs Screw M2.6x10 2 pcs Attaching GYRO C[...]
-
Page 63
4. INST ALLING OPTIONAL EQUIPMENT 4-3 4. Connect the GYRO CONVERTER board and J602 with two connector assemblies 03-2089 and 03-2090. 1 1 4 1 12 1 3 1 2 1 3 1 12 1 5 1 7 XH-PH connector assy . 03-2088 (6-14P) NH connector assy . 03-2091 (5P) VH connector assy . 03-2089 (5P) VH connector assy . 03-2090 (3P) J1 P1 J603 P603 GYRO CONVER TER 64P1106A T[...]
-
Page 64
4. INST ALLING OPTIONAL EQUIPMENT 4-4 5. Confirm gyrocompass specifications and set up the DIP switches and jumper wires on the GYRO CONVERTER board according to gyrocomp ass connected: x Setting jumper wires and DIP switches by gyrocomp ass specifications: page 4-5 x Setting jumper wires and DIP switches by make and model of gyrocomp ass: pa[...]
-
Page 65
4. INST ALLING OPTIONAL EQUIPMENT 4-5 Connection of external power supply An external power supply is necessary when the repeater signal is step-by-step type and the step voltage is below 20 V or output volt age is less than 5 W . 1. Cut jumper wire JP1 on the GYRO CONVERTER board when an external power supply is used. 2. Connect gyro cable and pow[...]
-
Page 66
4. INST ALLING OPTIONAL EQUIPMENT 4-6 Setting method 1: DIP switch settings and gyrocompass specifications 1) Gyrocompass type 2) Frequency Gyrocompass type SW 1-4 SW 1-5 SW 1-6 JP1 Frequency SW 1-7 SW 1-8 Remarks AC synchronous OFF OFF OFF #1, #2, #3 50/60 Hz OFF OFF AC synchronous pulsating current DC synchronous OFF OFF OFF #2, #3, #4 400 Hz ON [...]
-
Page 67
4. INST ALLING OPTIONAL EQUIPMENT 4-7 Setting method 2: by make and model of gyrocomp ass r e k a Ms l e d o Mo n i t a c i f i c e p SS W 1 - 1 W S 2 - 1 W S 3 - 1 W S 4 - 1 W S 5 - 1 W S 6 - 1 W S 7 - 1 W S 8 - 1 W S 1 - 2 W S 2 - 2 W S 3 - 2 1 P J2 P J3 P J4 P J5 P J z t u h c s n A, 3 2 d r a d n a t Su s o n o r h c n y s C A z H 0 6 / 0 5 V 0[...]
-
Page 68
4. INST ALLING OPTIONAL EQUIPMENT 4-8 Location of DIP switches, jumper wires on the GYRO CONVERTER board 64P1106 JP5, JP4 (Supply voltage) JP2 (Stator voltage) JP3 (Rotor voltage) JP1 (Gyro type) Fuse (2A) J5 (Rotor signal input, external power input) J4 (Stator signal input) SW1 DIP switch J6 (IEC-61162-1 output port) J7 (Data output port #1) J8 ([...]
-
Page 69
4. INST ALLING OPTIONAL EQUIPMENT 4-9 4.2 Memory Card Interface Unit Mounting considerations When selecting a mounting location, keep in mind the following points: x Locate the memory card interface unit away from heat sources because of heat that can build up inside the cabinet. x Locate the unit away from places subject to water splash and [...]
-
Page 70
4. INST ALLING OPTIONAL EQUIPMENT 4-10 Desktop mount For desktop mount, the optional desktop mount ki t FP03-10201 is required. Refer to the end of this manual. 1. Fix the mounting bracket 19-023-3081 on the unit with four screws. 2. Mount the above assembly on a desktop with four tapping screws. Console mount For console mount, the optional consol[...]
-
Page 71
4. INST ALLING OPTIONAL EQUIPMENT 4-1 1 No .1 Processor unit J614 NETWORK No .2 Processor unit No .3 Processor unit No .4 Processor unit MJ-A3SPF0015-100 (10 m) Memor y card IF unit 12 VDC FR-FTPC-CY (10/20/30 m) (straight) FR-FTPC-CY (10/20/30 m) (straight) FR-FTPC-CY (10/20/30 m) (straight) FR-FTPC-CY (10/20/30 m) (straight) FR-FTPC-CY (10/20/30 [...]
-
Page 72
4. INST ALLING OPTIONAL EQUIPMENT 4-12 4.3 DVI-RGB Conversion Kit (for VDR connection) This information provides the procedure nece ssary for the installation of the DVI-RGB conversion kit. This kit is inst alled in t he processor unit to enable connection of a VDR (V oyage Data Recorder) or RGB monitor to re cord radar pictures into a VDR. When ch[...]
-
Page 73
4. INST ALLING OPTIONAL EQUIPMENT 4-13 1. Remove the top cover and open the upper part of the processor unit. D VI-D por t (Connect D VI cable at step 13) Processor unit 2. Fix the 03P9229B board (RGB-BUFF) with four screws. (See the figure below .) 3. Attach the connector assemblies to J1 and J3 on the 03P9229B board as follows. J 1 㧦 13-pin[...]
-
Page 74
4. INST ALLING OPTIONAL EQUIPMENT 4-14 J4 D VI-RGB Conv ersion board J9 J3 (Connect D VI cable at step 10.) Fixing the DVI-RGB conversion board 6. Attach the 10-pin connector from J1 on the 03P9229B board to J9 on the DVI-RGB board. 7. Attach the connector assembly 03-2092 to J4 on the DVI-RGB conversion board. 8. Remove connector housing J615 from[...]
-
Page 75
4. INST ALLING OPTIONAL EQUIPMENT 4-15 4.4 Performance Monitor PM-31 This kit is installed in the antenna unit of the F AR-2107/2807 series X-band radar to monitor radar performance. Name: Performance monitor T ype: PM-31 Code no.: 008-080-438 Name T ype Code number Qty Ԙ SCANNER COVER ASSY . PM-31 008-539-430 1 ԙ GREASE GASKET GREASE #2 50G 000-[...]
-
Page 76
4. INST ALLING OPTIONAL EQUIPMENT 4-16 Lifting fixture * A P922 View Fix the cable. Stern side Bow side Gasket Lifting fixture Scanner cover assy Scanner cover assy Relay plate TB board J911 is on rear side. 1.Insert the lifting fixture as shown below. Lifting fixture Coating face Note:Fix flat side of the fixture to the coating face. 2. Fix the li[...]
-
Page 77
4. INST ALLING OPTIONAL EQUIPMENT 4-17 4.5 BNC Connector Converter T o connect the VR-5000 (FURUNO V oyage Dat a Recorder) to this radar , the DVI-RGB conversion kit (mentioned at previous paragraph) and the BNC connector converter are required. Also VGA cable (between the processor unit and the BNC connector converter) and five 75 ohms coaxial cab[...]
-
Page 78
4. INST ALLING OPTIONAL EQUIPMENT 4-18 4.6 Junction Box If the length of the antenna cable is more than 100 m, the optional junction boxes are required. These boxes should be mounted at the location protected because it s waterproofing is IPX3. R W -9600 (Max 15 m) Junction box RJB-001 R W -9600 (Max 15 m) DPYCY-6 (3 pcs.) TTYCY-4 (1 pc.) RG-12/UY [...]
-
Page 79
4. INST ALLING OPTIONAL EQUIPMENT 4-19 Cable fabrication RW -9600 6 14 5 9 appro x. 450 5 20 Armor Units: mm Shield Vinyl sheath Pull out inner cab les from here. Shield Coaxial cable Crimp on lug for M8 DPYC-6 and TTYC-4 20 5 6 DPYC-6: approx. 130 TTYCY -4: approx. 150 Conductor S = 0.75 mm = 1.11 mm 2 TTYCY -4 (Four twisted pairs) Armor Sheath = [...]
-
Page 80
4. INST ALLING OPTIONAL EQUIPMENT 4-20 Connection Insert each cable to the cable gland as follows. Flat washer Cable gland Vinyl sheath Clamping gland Gasket Cut and trim ar mor . Connect each cable cores to the terminal board, referring to the interconnection diagram on next page. 15 14 13 12 11 10 9876 5 4 3 21 RG12/UY RG-12/UY TTYCY-4 DPYCY-6 RW[...]
-
Page 81
4. INST ALLING OPTIONAL EQUIPMENT 4-21 RED[B] GRN[B] WHT BRK GRN RED WHT[B] PPL[B] COAX GLY[B] BLU[B] YEL[B] ORG[B] BRN N.C. N.C. N.C. 03P9349 TB802 12 2 13 14 3 4 5 6 7 8 9 10 11 1 TB801 1 2 GND SIG-GND 1 2 Junction box Antenna unit GND IF_VIDEO RF_SPU_D_B RF_SPU_D_A SPU_RF_D_B SPU_RF_D_A MOTOR(-) MOTOR(-) MOTOR(+) MOTOR(+) 24V_MINUS 24V_PLUS N.C.[...]
-
Page 82
4. INST ALLING OPTIONAL EQUIPMENT 4-22 This page is intentionally lef t blank.[...]
-
Page 83
5-1 5. INPUT/OUTPUT DA T A Input and output data are shown in the t able below . Note: This radar accept s position dat a fix ed by WGS-84 geodetic datum only . Set the datum to WGS-84 on the EPFS (GPS, etc.) connecte d to this radar . If other type of datum is input, the error message "DA TUM" appears and the AI S feature is inoperative.[...]
-
Page 84
5. INPUT/OUTPUT DA T A 5-2 IEC 61 162 input sentence and priority Content s Sentence and priority S peed (STW) S peed (SOG) S peed (position) Heading (T rue) Position Datum W aypoint Route Date Depth T emperature Wind Set and Drift ALARM ACK VBW>VHW VBW VTG>RMC THS*>HDT* GNS>GGA>RMC>GLL DTM BWR>BWC> RMB WPL, RTE ZDA DPT >[...]
-
Page 85
%1&'01 6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ ).: ?[...]
-
Page 86
%1&'01 6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ (5: ?[...]
-
Page 87
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 ).: /7%4 0#/' 176.+0' &'5%4+26+10%1&'ͳ 36; ࡙࠾࠶࠻ 70+6 ␜ㇱ &+52.#;70+6 /7%45*-#6 [...]
-
Page 88
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 )/: /7%4 0#/' 176.+0' &'5%4+26+10%1&'ͳ 36; ࡙࠾࠶࠻ 70+6 ␜ㇱ &+52.#;70+6 /7%45*-#4 [...]
-
Page 89
%1&'01 6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ #%↪ ).:[...]
-
Page 90
%1&'01 6;2' (2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 #%%'5514+'5 ઃዻຠ ).: -$⋥ઃ㊄?[...]
-
Page 91
%1&'01 6;2' (2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 #%%'5514+'5 ઃዻຠ ).: 㩖㩡㨹㩆?[...]
-
Page 92
%1&'01 6;2' (2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 #%%'5514+'5 ઃዻຠ ).: ขᚻ *#0&am[...]
-
Page 93
%1&'01 6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ )1: ?[...]
-
Page 94
%1&'01 6;2' (2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 #%%'5514+'5 ઃዻຠ )1: 㩄㩧㩉㨺?[...]
-
Page 95
0#/' 176.+0' 36; &'5%4+26+10%1&'ͳ 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 ).: )% 0#/' 176.+0' 36; &'5%4+26+10%1&'ͳ ੍ຠ 52#4'2# 465 ੍ຠ 52#4'2#465 52 ?[...]
-
Page 96
%1&'01 6;2' 12 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ ).: ?[...]
-
Page 97
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 ).: 12 0#/' 176.+0' &'5%4+26+10%1&'ͳ 36; ߘߩઁㇱຠ 16*'4 2#465 㩏㩗㩨㩈㩛㩇$ 9#5*'4*'#&5%4'9 /:%9/$0+ [...]
-
Page 98
For antenna unit motor For display unit (MU-201CR/231CR, AC se t) For display unit (MU-201CR, DC set) A -27 %1&'01 6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 ⇟ภ 01 ?[...]
-
Page 99
For processor unit (24 VDC set) For GC-10 A -29 For display unit (MU-231CR, DC set) For processor unit (100 V AC set) For processor unit (220 V AC set) A -28[...]
-
Page 100
D-1[...]
-
Page 101
D-2[...]
-
Page 102
Jun.11'08 R.Esumi D-3[...]
-
Page 103
D-4[...]
-
Page 104
D-5[...]
-
Page 105
D-6[...]
-
Page 106
D-7[...]
-
Page 107
D-8[...]
-
Page 108
D-9[...]
-
Page 109
D-10[...]
-
Page 110
D-11[...]
-
Page 111
D-12[...]
-
Page 112
/C[ 4'UWOK D-13 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, email=ryosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:43:45 +09'00'[...]
-
Page 113
D-14[...]
-
Page 114
D-15[...]
-
Page 115
D-16[...]
-
Page 116
D-17[...]
-
Page 117
Jan.18'08 R.Esumi D-18[...]
-
Page 118
#RT4'UWOK D-1 9 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, email=r yosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:44:45 +09'00'[...]
-
Page 119
#RT4'UWOK D-20 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, email=ryosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:45:10 +09'00'[...]
-
Page 120
#RT4'UWOK D-21 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, em ail=ryosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:44:02 +09'00'[...]
-
Page 121
#RT4'UWOK D-22 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, email=ryosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:44:16 +09'00'[...]
-
Page 122
#RT4'UWOK D - 23 esumi 電子署名者 : esumi DN: cn=esumi, c=JP - 日本 , o=kisou, ou=toukatu, ema il=ryosuke.esumi@furuno.co.jp 日付 : 2007.12.26 17:44:31 +09'00'[...]
-
Page 123
D-24[...]
-
Page 124
D-25[...]
-
Page 125
D-26[...]
-
Page 126
D-27[...]
-
Page 127
D-28[...]
-
Page 128
D-29[...]
-
Page 129
D-30[...]
-
Page 130
D-31[...]
-
Page 131
Apr. 05 '04 D- 3 2[...]
-
Page 132
12 4 35 6 A B C D MASS SCALE DWG.No. APPROVED CHECKED DRAWN kg 名称 TYPE NAME *4 50-60Hz 100VAC,1φ, 220/230VAC, 110/115/ 1φ,50-60Hz 氷結防止用 FOR DE-ICER GYROCOMPASS A-D CONVERTER RGB EXT. MONITOR 03P9229A RGB バッファ 基板 RGB BUFFER PCB RW-4747 J615 J3 J4 SLB-FRN4-A DVI-RGB CONVERSION BOARD DVI-RGB変換基板 BNCコネクタ?[...]
-
Page 133
12 4 35 6 A B C D MASS SCALE DWG.No. APPROVED CHECKED DRAWN kg 名称 TYPE NAME 100/110/115/ 200/220/240VAC 1φ,50/60Hz DPYC-2.5 *1 *2 整流器 RECTIFIER RU-3424 *4 50-60Hz 100VAC,1φ, 220/230VAC, 110/115/ 1φ,50-60Hz 氷結防止用 FOR DE-ICER TTYCS-4 *1 MPYC-7 *1 GYROCOMPASS A-D CONVERTER RGB EXT. MONITOR 12-24VDC 03P9229A RGB バッファ ?[...]
-
Page 134
# $ % & /#55 5%#.' &9)0Q #22418'& %*'%-'& &4#90 MI ฬ⒓ 6;2' 0#/' *7$ 21465 * 8#%Ǿ 8#% Ǿ* ᳖⚿㒐ᱛ↪ (14 &&apos[...]
-
Page 135
# $ % & /#55 5%#.' &9)0Q #22418'& %*'%-'& &4#90 MI ฬ⒓ 6;2' 0#/' 8#% Ǿ* &2;% ᢛᵹེ 4'%6+(+'4 47 *7$?[...]