A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Gardena Comfort Pump 8500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Gardena Comfort Pump 8500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Gardena Comfort Pump 8500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Gardena Comfort Pump 8500 should contain:
- informations concerning technical data of Gardena Comfort Pump 8500
- name of the manufacturer and a year of construction of the Gardena Comfort Pump 8500 item
- rules of operation, control and maintenance of the Gardena Comfort Pump 8500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Gardena Comfort Pump 8500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Gardena Comfort Pump 8500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Gardena service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Gardena Comfort Pump 8500.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Gardena Comfort Pump 8500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    D GB F NL S DK FIN N I E P PL H CZ SK GR RUS SLO HR SRB BIH UA RO TR BG AL ES T LT LV GA RDE NA ® D Betriebsanleitung T auchpumpe / Schmutzwasserpumpe GB Operating Instructions Submersible Pump / Dirty W ater Pump F Mode d’emploi Pompe d’évacuation pour eaux claires / Pompe d’évacuation pour eaux chargées NL Instructies voor gebruik Dompe[...]

  • Page 2

    Intended use Liquids to be pumped Please note GARDENA Su bme r si bl e P ump 9000 / 13000 aquasensor / Di rty W ate r Pu mp 8500 / 13000 aquasensor T ranslation of the original instructions from Ger man. Please read these operating instructions carefully and obser ve the notes giv en. Use the instructions to familiarise yourself with the pump , its[...]

  • Page 3

    12 GB 2. Safety Instructions Electrical Safety According to DIN VDE (Ger man Electrical Engineers’ Association) 0100, submersible pumps and dir ty water pumps ma y only be used in swimming pools , garden ponds, and fountains if the pump is oper ated via a residual-current de vice with a residual-current rating of ≤ 30 mA. The pump must not be o[...]

  • Page 4

    13 GB Instructions for submer sible pumps When you pur chase your pump the s wivel feet are set to the flat suction position (1 mm). v For normal operation, turn the feet 1 80 ° to 5 mm. The pump is lifted 5 mm. v Clear the outlet line before use . Thermal protection s witch The pump is automatically switched off on ov erheating by the built-in th[...]

  • Page 5

    14 GB Automatic operation : 2. Only f or the submersible pumps Art. No. 1783 / 1785 : Inser t the non-return valve z V supplied into the universal connector 2 with the word UP pointing upwards . 3. Screw the univ ersal fitting 2 onto the pump . 4. Connect the hose to the univ ersal fitting 2 . We recommend 38 mm (1 ¹⁄₂ " ) 25 mm (1 "[...]

  • Page 6

    15 GB Manual operation : Only f or the submersible pumps : Flat suction / Normal operation The pump remains in operation continuously . The ON sensor 3 is lock ed in manual position and bridged via the contact 7 . 1. Push OFF sensor 4 and ON sensor 3 right down so that the ON sensor 3 touches the contact 7 . 2. Stand the pump on a firm surface – [...]

  • Page 7

    16 GB Flushing the Pump : Clean sensors : Cleaning the suction base and impeller : 6. Maintenance The pumps are vir tually maintenance-free. After having pumped chlorinated s wimming pool water or other liquids leaving residues , the pump should be r insed with clear wate r. The sensors will only w ork reliably if the y are cleaned regu- larly (at [...]

  • Page 8

    17 GB Problem Probable cause Remedy Pump is running, When star ting the pump , v Submerge pump deeper. but doesn’t deliver water height falls belo w the min. water lev el. The pump does not switch Sensors 3 / 4 and contacts 7 v Clean sensors (see on or off. Pump switches off are dir ty . 6. Maintenance). although the OFF sensor is in the water Pu[...]

  • Page 9

    18 GB 9. Ser vice / W arranty GARDENA guarantees this product f or 2 years ( from date of purchase). This guar antee covers all serious def ects of the unit that can be prov ed to be material or manufacturing faults . Under warranty w e will either replace the unit or repair it free of charge if the follo wing conditions apply : • The unit must h[...]

  • Page 10

    227 7000 Art. 1 783 / 1785 7500 Art. 1 797 / 1799 K ennlinie T auchpumpe P erformance characteristics Submersible Pump Courbe de performance Pompe d’évacuation pour eaux clair es Prestatiegrafiek Dompelpomp Kapacitetskurva Dränkbar pump Ydelses karakteristika Dykpumpe Ominaiskäyrä Uppopumppu Merkingslinje for Lensepumpe Curva di rendimento pe[...]

  • Page 11

    228 D Produkthaftung Wir weisen ausdrüc klich darauf hin, dass wir nach dem Produkthaftungsgesetz nicht für durch unsere Geräte hervorgerufene Schäden einzustehen haben, sof er n diese durch unsachgemäße Reparatur v er ursacht oder bei einem T eileaustausch nicht unsere Or iginal GARDENA T eile oder von uns freigegebene T eile verw endet werd[...]

  • Page 12

    230 D EG-Konf ormitätserklärung Der Unterzeichnete Husqvarna AB, 561 82 Huskvarna, Sweden bestätigt, dass die nachfolgend bezeichneten Geräte in der von uns in V erkehr gebrachten Ausführung die Anforderungen der harmonisierten EU-Richtlinien, EU-Sicherheitsstandards und produktspezifischen Standards erfüllen. Bei einer nicht mit uns abgestim[...]

  • Page 13

    231 Harmonisier te EN : EN ISO 12100 - 1 EN ISO 12100 - 2 EN 60335 - 1 EN 60335 - 2 - 41 Hinterlegte Dokumentation : GARDENA T echnische Dokumentation E. Renn 89079 Ulm Deposited Documentation : GARDENA T echnical Documentation E. Renn 89079 Ulm Documentation déposée : Documentation technique GARDENA E. Renn 89079 Ulm Anbringungsjahr der CE-Kennz[...]

  • Page 14

    232 Deutschland / Germany GARDENA GmbH Central Service Hans-Lorenser-Straße 40 D - 89079 Ulm Produktfragen: (+ 49) 731 490 - 123 Reparaturen: (+ 49) 731 490 - 290 service @ gardena.com Albania COBAL T Sh.p.k. Rr . Siri K odra 1000 Tirana Argentina Husqvarna Argentina S.A. Av .del Liber tador 5954 - Piso 11 - T orre B (C1428ARP) Buenos Aires Phone [...]