A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GarrettCom Magnum 6KQ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GarrettCom Magnum 6KQ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GarrettCom Magnum 6KQ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GarrettCom Magnum 6KQ should contain:
- informations concerning technical data of GarrettCom Magnum 6KQ
- name of the manufacturer and a year of construction of the GarrettCom Magnum 6KQ item
- rules of operation, control and maintenance of the GarrettCom Magnum 6KQ item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GarrettCom Magnum 6KQ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GarrettCom Magnum 6KQ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GarrettCom service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GarrettCom Magnum 6KQ.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GarrettCom Magnum 6KQ item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
i www Garre t t C om c om .. www Garre t t C om c om .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.GarrettCom .com email support@garrettc om.com Magnum 6KQ Managed Field Switch Hardware Installation and User Guide[...]
-
Page 2
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) i www Garre t t C om c om .. Magnum 6KQ Managed Field Switch Hardware Installation and User Guide Part #: 84-00180Z (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Labor[...]
-
Page 3
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) ii www Garre t t C om c om .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.GarrettCom .co[...]
-
Page 4
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) iii www Garre t t C om c om .. Table of Contents .............................................................................. Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Speci fications .................[...]
-
Page 5
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) iv www Garre t t C om c om .. 5.2.2. 6KQF-2MSC Fiber connector .................................................... 37 5.2.3 6KQF-2SSCL FX-SC-type, Sgl.M ........................................... 37 5.2.4 6KQ3-RJMSC “COMBO” connector ....................................... 3[...]
-
Page 6
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) www Garre t t C om c om .. THE MAGNUM LINE Industrial net working products "Designed and Manufactured i n the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM LINE OF INDUSTRIAL CONECTIVITY PR ODUCTS WITH INDUSTRY-STANDARD FUNCTIONALITY AND BUILT-IN FI[...]
-
Page 7
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1 www Garre t t C om c om .. 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward w ith IEEE 802.3x[...]
-
Page 8
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 2 www Garre t t C om c om .. 1000BASE-SX, full-duplex, multi-mode(50 m cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5 m cable) -5Km Fiber Multi-mode connector typ es supported: Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BA SE-FL Fiber Port, MTRJ-typ[...]
-
Page 9
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 3 www Garre t t C om c om .. 12 watts typical (for a small 4 port copper-only model) DC-DUAL POWER SOURCE (OPTIONAL) For DC internal power supplies at –48VDC, 24VDC and 125VDC, with the Dual-Source option ( for continuity of operation when either of the DC input sources are inter[...]
-
Page 10
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 4 www Garre t t C om c om .. 1.2 Ordering Information Magnum Managed Field Switch (16 ports max) MODEL DESCRIPTION Magnum 6KQ- 24VDC Magnum 6KQ Managed Field Sw itch, base unit with 24VDC power supply and four 10/100 copper ports. Ma y be configured with a selection of 10/100/1000 [...]
-
Page 11
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 5 www Garre t t C om c om .. 6KQF-4MT “4 ports” module, w/four 100Mb mm 2km FX MTRJ’s fiber ports 6KQF-4MLC “4 ports” module, w/four 100Mb mm 2km FX LC’s fiber ports 6KQF-4SLC “4 ports” module, w/four 100Mb Sm, 15km FX LC’s fiber ports 6KQF-2MST “2 ports” modu[...]
-
Page 12
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 6 www Garre t t C om c om .. 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of t[...]
-
Page 13
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 7 www Garre t t C om c om .. 2.2 Product Description - Magnum 6KQ Field Switch Magnum 6KQ Managed Field Switches provide m aximum configurability in their class. The fiber-rich 6KQ can be c onfigured with up to 12 100Mb fiber ports and two Gigabit ports. For 10/100 copper, re g[...]
-
Page 14
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 8 www Garre t t C om c om .. The 6KQ managed switches also provide PoE options via power – inside PoE modules on one of A, B or C slots and allows the users to select a wide option of combo PoE modules to support 802.3af pd de vices. See details for PoE modules in sec 5.2.10. The[...]
-
Page 15
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 9 www Garre t t C om c om .. 1 2 3 4 AC F/H ACT F/H LK LK LK LK ACT F/H ACT F/H Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and software through traps, providing a record of any losses of power signals and other user- defined software events. S ee S[...]
-
Page 16
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 10 www Garre t t C om c om .. on the port. A fiber cab l e must be c onne c t ed into a SFF port and the Link (LK) indica tor for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of opera[...]
-
Page 17
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 11 www Garre t t C om c om .. dependent upon the -48VDC input power to supply the PD power for these RJ-45 (10/100) ports. Each port supplies up to 15w atts to power the PoE PD devices. A maximum of 8 PoE ports can be configured in the A and B slots of a 6KQ switch with - 48vdc pow[...]
-
Page 18
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 12 www Garre t t C om c om .. 2.2.5 Two -Port 10 Mb mm Fiber ST Modules The 2-port @10Mb ST fiber modules behave the same as the 2@100Mb ST fiber modules except for the 10Mb speed. The default setup on the 10Mb fiber module is half-duplex, which allows the Magnum 6KQ Switch to conn[...]
-
Page 19
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 13 www Garre t t C om c om .. There are three LEDs mounted on each Gigabit port module. The Gigabit fiber has LEDs that indicate F/H (Full/Half duplex), LK (Link status) and ACT (receiving activity) on that port when lit. The copper Gigabit ports come with speeds indicating (10/100[...]
-
Page 20
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 14 www Garre t t C om c om .. load is greatest. When the Magnum 6KQ Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending it packets to cause “flow control”. Th is tells the sending[...]
-
Page 21
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 15 www Garre t t C om c om .. 2.3 Features and Benefits Managed switching for high performan ce Ethernet LANs Magnum 6KQ Switches provide unicast non-blocki ng (all ports can run at full speed at once) performance with standard Manage d Network Software (MNS-6K) included. They [...]
-
Page 22
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 16 www Garre t t C om c om .. 2.4 Applications Magnum 6KQ Field Switches offer high performance, modularity and availability. They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit (1000Mb) ports, w ith industry-standard LAN management soft[...]
-
Page 23
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 17 www Garre t t C om c om .. fiber media provide widespread options to th e users to mix and match their legacy and advance network needs. The modularity of the 6KQ Managed Field Switches make them an attractive choice for use in applications with LAN connections to an organizatio[...]
-
Page 24
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 18 www Garre t t C om c om .. power failure can bring the whole thing down, a ring switch can be reconfigured and up and running in milliseconds. The ring topology of the network consists of high speed LAN segments supported by 100Mbps full-duplex future-proof fiber media to provid[...]
-
Page 25
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 19 www Garre t t C om c om .. Example 3. In another application in an indus trial environment, a 12 port Nebs compliant, -24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV. The switch must be SNMP enabled and managed to [...]
-
Page 26
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 20 www Garre t t C om c om .. For DC power input data, see Appendix B. For Dual Source, see Appendix C . The rugged metal case of the Magnum 6KQ will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually monitor the[...]
-
Page 27
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 21 www Garre t t C om c om .. 2. Wipe clean the ends of the dual connect ors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting. Note: One strand of the duplex fiber optic cab le is coded using color bands at regu[...]
-
Page 28
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 22 www Garre t t C om c om .. NOTE : It is recommended that high quality CAT. 5 cable be used whenever possible in order to provide flexibility in a mixed-speed network, since 10/100 copper switched ports are auto-sensing for either 10 and 100Mb/s. The following procedure describes[...]
-
Page 29
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 23 www Garre t t C om c om .. 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers The small form-factor pluggable (SFP) is a co mpact optical transceiver used in optical communications for both telecommunication a nd data communications applications. Due to its com[...]
-
Page 30
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 24 www Garre t t C om c om .. The various SFPs transceivers supported by GarrettCom 6KQs D slot are- 3.2.6a Connecting Fib er Optic Cable to SFP Trans ceivers 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM. Save[...]
-
Page 31
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 25 www Garre t t C om c om .. fiber optic segment. 3. Find the Transmit (TX) and Receive (RX) m arkings on the SFP transceiver to verify the top side of it. Some of the transceiver marks arrow sign for up. 4. Position the SFP tra nsceiver correctly be fore insertion, and then inser[...]
-
Page 32
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 26 www Garre t t C om c om .. The Din Rail Latching clips are mounted on the upper side corners of the 6KQ unit. Two threaded holes are provided on the sides of 6KQ for DIN- Rail mounting purposes. See side view at the left. The required two screws are included with the DIN-Rail br[...]
-
Page 33
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 27 www Garre t t C om c om .. air circulation and cooling of th e rear part of the case. For best cooling of the 6KQ, attach the me tal brackets to metal (rather than wood or plastic). Attaching to metal helps condu ct heat away from the 6KQ through the metal brackets and into th e[...]
-
Page 34
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 28 www Garre t t C om c om .. consumption will range from about 20 up to 35 watts, depending on the port quantity and types in the configuration.. When connecti ng the Ethernet cabling, there is no need to power down the unit. Individual cable segm ents can be connected or disconne[...]
-
Page 35
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 29 www Garre t t C om c om .. The Alarm Contacts are on the front left area (next to the DC pow er source) of the Magnum 6KQ unit and are green in color as shown in the picture. 3.6 6KQ Port Module (6KPM) Installation Magnum 6KQ Switches are normally received from the factory with [...]
-
Page 36
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 30 www Garre t t C om c om .. The Hyper terminal configuration is exactly the same as all other 6K-Family managed switches. Please check the following URL for details- http://www.garrettcom.com /techsupport/sof tware/userguides/mns6k_CLI.pdf NOTE: The console RJ-45-Serial cable may[...]
-
Page 37
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 31 www Garre t t C om c om .. to the other ports where it is not needed . Traffic needed for m aintaining the un- interrupted operation of the network (such as occasional multi-cast p ackets) is forwarded to all ports. The Magnum 6KQ Switches operate in the store-and-forward switch[...]
-
Page 38
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 32 www Garre t t C om c om .. this manual to access the “6K-MNS(Rel 3) Software user guid e” One frequently-used application for the Managed Magnum 6KQ Switch copper ports is to connect one of them using a fi ber media converter to another Switch in the network backbone, or to [...]
-
Page 39
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 33 www Garre t t C om c om .. NOTE – Some NIC cards on ly auto-negotiate when the compu ter system that they are in is power ed. These are exceptions to the “n egotiate at LINK – enabled” rule above, but may be occasionally encoun tered. When operating in 100Mb half-[...]
-
Page 40
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 34 www Garre t t C om c om .. Worst case distance = {Wors t case OPB, in dB} / [Cable Loss, in dB/Km ] where the “Cable Loss” for 62.5/125 and 50/125 m (M.m) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Si[...]
-
Page 41
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 35 www Garre t t C om c om .. The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the full-duplex (factory default) setting fo r 100Mbps fiber ports must be used, and The worst-case OPB of the fiber link must be greater than the fiber cable’s passiv[...]
-
Page 42
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 36 www Garre t t C om c om .. Note: The 6KQ Port modules are n ot identical to the port modu les used in other 6K products such as the 6K25e and 6K16V . For information about other 6K products, please s ee the applicable manual. For a lis t of 6KQ Port Modules, refer to Section 1.2[...]
-
Page 43
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 37 www Garre t t C om c om .. the IEEE-standard 10Mbps dist ance limits, i.e., typically 2km at full-duplex and half- duplex. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, a[...]
-
Page 44
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 38 www Garre t t C om c om .. 5.2.4 6KQ3-RJMSC “COMBO” 2@ 10/100Mbps RJ-45 Ports and 1@100Mbps Multi-mode FX-SC-type, “snap-in” connector The Magnum 6KPQ-RJMSC is also a Combo module equipped with 2 dual speed copper ports and 1 Multi-mode SC-type connector. It provides an [...]
-
Page 45
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 39 www Garre t t C om c om .. The functionality of this 100BASE-FX multi-mode 4-port module is essentially the same as the ST and SC -types. It has the same LEDs per port indicating port activity (ACT), Link (LK), and FDX or HDX operation. 5.2.6 6KQ4-RJMT, “COMBO” 2@ 10/100Mbps[...]
-
Page 46
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 40 www Garre t t C om c om .. The cable end is a “plug-in” connector with both fiber strands terminated in one housing that cannot be improperly insert ed. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating proper connectivity with[...]
-
Page 47
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 41 www Garre t t C om c om .. “10/100” LED indicating 100Mb when lit (or 10 Mbps when off). Note: The 10/100 RJ-45 ports are supported with Auto-negotiation and Auto- crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-45 device and eliminate th e us[...]
-
Page 48
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 42 www Garre t t C om c om .. 5.2.11 SFPs, Gigabit (1000Mbps) port modules The Magnum 6KQ offers a Gigabit option with multiple choices of copper 10/100/1000Mbps or Gigabit SFP Fiber modules for the modular slot. While up to two Gigabit modules (maxm.) can be configur ed in the mod[...]
-
Page 49
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 43 www Garre t t C om c om .. 5.2.12 6KQ-BLNK The 6KQ-BLNK is a bl a nk face plate or cover plate that must be installed in any empty 6KQ PM slot to maintain proper cooling air flow, safety, etc. Two screws underneath the front panel hold the 6KQ-BLNK in place. 6.0 TROUBLESHOOTING [...]
-
Page 50
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 44 www Garre t t C om c om .. 6.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The [...]
-
Page 51
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 45 www Garre t t C om c om .. 1. P ackage the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation[...]
-
Page 52
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 46 www Garre t t C om c om .. APPENDIX B : DC Power Input B1.0 Specifications for Magnum 6KQ Sw itches, DC Power at 24V and – 48V and 125V DC Power input Each Magnum Model 6KQ Managed Switch requi res DC power input, at either 24VDC, -48VDC or 125VDC nominal. The wide range of DC[...]
-
Page 53
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 47 www Garre t t C om c om .. other communication companies. In addition, m any high availability equipment services, such as broadcasters, publis hers, newspaper operations, brokerage firms and other facilities often use a battery backup system to maintain operations in the event [...]
-
Page 54
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 48 www Garre t t C om c om .. secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block. B5.0 OPERATION Operation of Magnum 6KQ Switches with the optional -48VDC, 24VDC and 125VDC dual-source power input is identical to [...]
-
Page 55
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 49 www Garre t t C om c om .. C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four external power connection termin[...]
-
Page 56
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 50 www Garre t t C om c om .. “+ve potential”. The more “+ ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”. The connection procedure is straightforw ard. Simply connect the DC leads to the Switch’s power terminals, positive (+) and[...]