Go to page of
Similar user manuals
-
Air Conditioner
GE AJCH 08 ACA, AJCH 10 ACA, AJCH 10 DCA, AJCH 12 DCA, AJCS 06 LCA, AJCS 08 ACA, AJCS 10 ACA, AJCS 09 DCA, AJCS 10 DCA, AJCS 12 DCA, AJES 09 DCA, AJES
16 pages 0.53 mb -
Air Conditioner
GE ASV18DK
2 pages 0.16 mb -
Air Conditioner
GE ASP12
20 pages 0.81 mb -
Air Conditioner
GE ASP10
20 pages 0.8 mb -
Air Conditioner
GE AGE14
20 pages 0.44 mb -
Air Conditioner
GE AJEH 12
76 pages 2.05 mb -
Air Conditioner
GE ASP12
20 pages 0.84 mb -
Air Conditioner
GE ACB AJCS 09
72 pages 2.07 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GE 49-7419-2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE 49-7419-2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GE 49-7419-2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GE 49-7419-2 should contain:
- informations concerning technical data of GE 49-7419-2
- name of the manufacturer and a year of construction of the GE 49-7419-2 item
- rules of operation, control and maintenance of the GE 49-7419-2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE 49-7419-2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE 49-7419-2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE 49-7419-2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GE 49-7419-2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
49-7419-2 04-02 JR Air Con di t i o n ers Safety Instr uctions . . . . . . . . . . .2 Operating Instr uctions Controls—Dip Switches . . . . . .3–5 Controls—T erminal Connections . . . . . . . . . . . . . .6, 7 On/Off Switch . . . . . . . . . . . . . . .8 V entilation Control . . . . . . . . . . .8 Care and Cleaning Air Filters . . . . . . . .[...]
-
Page 2
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire, electric shock, or to prevent property damage, personal injury , or loss of[...]
-
Page 3
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 3 Controls–dip switches. GEAppliances.com The dip switch controls are located behind the front case panel, through an opening on the front of the unit. T o access the dip switches, remove the front case panel by removing the filter , taking out th[...]
-
Page 4
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 4 Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RA VRMS) When this switch is enabled (UP) , it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN) , the freeze sentinel is activated which auto[...]
-
Page 5
5 Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support GEAppliances.com T emperature Limiting (Requires room air sensor kit–RA VRMS) T emperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. T[...]
-
Page 6
6 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Controls—terminal connections. Controls–T erminal Connections The terminal connections are located behind the front case panel through an opening on the front of the unit. T o access the terminal connections, remove the front panel by removing[...]
-
Page 7
Remote Thermostat The unit will be controlled by a remote thermostat. IMPORT ANT : The Zoneline thermostat connections provide 24V AC only . If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat. CAUTION: Damage to a wall thermostat or to the Zoneline electron[...]
-
Page 8
8 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Other features of your Zoneline. About Heat Pumps (on some models) Heat pumps can reduce operating costs by exchanging heat from the outside air—even when the outside temperature is below freezing— and releasing that heat indoors. T o get the [...]
-
Page 9
Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly . If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE ser vice center . Y ou will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on the exhaust side. 9 Safety Instructions Operating I[...]
-
Page 10
BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Obser ve all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the owner . • Note to O[...]
-
Page 11
11 Installation Instructions ELECTRICAL REQUIREMENTS 230/208 VOL T ELECTRICAL SUPPL Y T andem 15 Amp 230/208 volt receptacle configuration Perpendicular 20 Amp Large T andem 30 Amp • Use ONLY the wiring size recommended for single outlet branch circuit. • Proper current protection is the responsibility of the owner . A power supply kit must be [...]
-
Page 12
REMOVE JUNCTION BOX COVER • Remove the junction box cover by taking out the front two screws. 1 Junction box Installation Instructions 12 DIRECT CONNECT APPLICA TIONS FOR 265 VOL T DIRECT CONNECT APPLICA TIONS ONL Y IMPORT ANT: Connection of a 265V AC product to a branch circuit MUST be done by direct connection in accordance with the National El[...]
-
Page 13
13 Installation Instructions DIRECT CONNECT APPLICA TIONS MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 2. Select the applicable wiring situation and follow the instructions accordingly: 3. Be sure that all wire leads are inside the junction box a[...]
-
Page 14
Installation Instructions 14 ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.) Architectural Louver RA V AL1 W all Plenum RA VWP6 - 6 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP8 - 8 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP12 - 12 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H[...]
-
Page 15
Installation Instructions 15 TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONL Y) Side View T op View Architectural Louver 10 ″ duct Door/access panel 3 ″ min. 5 ″ min. Unit front 3 ″ min. Exterior/Outside Unit Outside wall Wall plenum Inside wall Air discharge outlet Rigid ductwork Flexible or rigid duct Wall plenum divider 31 ″ O[...]
-
Page 16
Installation Instructions 16 UTILITY CLOSET CONNECTION LOCA TIONS IMPOR T ANT : Plan and locate plenum, wall plug, drain and thermostat carefully to avoid interference. Hard-to-reach locations will make installation and service difficult! Refer ence Dimensions A Thermostat cable: 9 1 ⁄ 2 ′ long B Power cord: 60 ″ long C Case width and depth: [...]
-
Page 17
Installation Instructions 17 RETURN AIR GRILLE INST ALLA TION OPTIONS The room return air grille may be installed toward the front or either side of the unit. Improper return air arrangements will cause per formance problems. There are three indoor Return Air Grille Installation options. Choose the option that best suits your installation requireme[...]
-
Page 18
BUILD AND INST ALL THE ZONELINE BASE PLA TFORM 1. Construct a 23 1 ⁄ 4 ″ min. x 23 1 ⁄ 4 ″ min. square platform. NOTE: The platform must have a load-bearing capacity of 175 lbs. minimum. 1 Installation Instructions 18 W ALL PLENUM AND ARCHITECTURAL LOUVER INST ALLA TION • Install the appr opriate wall plenum through the exterior wall in a[...]
-
Page 19
INST ALL THE DRAIN An exter nal or an inter nal drain must be attached to the drain connector . Exter nal Drain Attach a 90° PVC elbow to the unit’ s female 3/4 ″ NPT drain connector . Use the other end of the elbow to run a 3/4 ″ Sch.40 PVC pipe through the knockout holes of both the wall plenum and the architectural louver to the outside. [...]
-
Page 20
INST ALL AND CONNECT THE CASE 1. Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case to the plenum opening and attach with six screws. 2. Adjust all four leveling legs until the case is level. 3. Using field-supplied [...]
-
Page 21
T op duct Clamp Case top duct adjusting screws MAKE UNIT ELECTRICAL CONNECTIONS 1. Connect the thermostat wires to the unit and set the dip switches to the appropriate settings. NOTE: See the Controls–T erminal Connections and Controls–Dip Switches sections of this manual and the manual with the separate thermostat for proper connections and se[...]
-
Page 22
Installation Instructions SERVICING W ARNING: Before ser vicing, switch power off at the ser vice panel and lock the area to prevent power from being switched on accidentally . When the area cannot be locked, securely fasten a prominent warning device, such as a tag, to the ser vice panel. NOTE: W e strongly recommend that any ser vicing be per for[...]
-
Page 23
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support Before Y ou Call For Service… GEAppliances.com T roubleshooting T ips Problem Possible Causes What T o Do Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged. into the outlet. The fuse is blown/circui[...]
-
Page 24
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 24 Normal Operating Sounds Y ou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency . Y ou may hear re[...]
-
Page 25
25 General Electric Company W ar ranty Registration Depar tment P .O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here[...]
-
Page 26
26 Consumer Pr oduct Ownership Registration Important Mail T oday! General Electric Company Louisville, Kentucky GEAppliances.com First Name Mr . ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Y ear Zip Code Apt. # Last Name Phone Number _ _ Consumer Pr oduct Ownership Registration Dear Customer[...]
-
Page 27
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support 27 V ertical Zoneline Warranty . For The Period Of: GE Will Replace: One Y ear Any part of the Zoneline which fails due to a defect in materials or workmanship. During this From the date of the full one-year warranty , GE will also provide, free of [...]
-
Page 28
Printed in China Consumer Support. GE Appliances W ebsite GEAppliances.com Have a question or need assistance with your appliance? T ry the GE Appliances W ebsite 24 hours a day , any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can [...]