Go to page of
Similar user manuals
-
Ventilation Hood
GE BF100S
2 pages 0.24 mb -
Ventilation Hood
GE ZV850
16 pages 0.27 mb -
Ventilation Hood
GE JV334R
4 pages 0.06 mb -
Ventilation Hood
GE JV248PSS
2 pages 0.2 mb -
Ventilation Hood
GE GE Profile JV696SCC
2 pages 0.09 mb -
Ventilation Hood
GE JV965
24 pages 0.4 mb -
Ventilation Hood
GE ZVB36BN
4 pages 0.52 mb -
Ventilation Hood
GE GE Deluxe JV247PWW
2 pages 0.21 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GE ZV421, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE ZV421 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GE ZV421. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GE ZV421 should contain:
- informations concerning technical data of GE ZV421
- name of the manufacturer and a year of construction of the GE ZV421 item
- rules of operation, control and maintenance of the GE ZV421 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE ZV421 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE ZV421, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE ZV421.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GE ZV421 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
If you have questions , call 800.GE.CARES or visit our website at: monogram.com Installation Instructions Island V ent Hoods Models: ZV42 I ZV54 I[...]
-
Page 2
2 Installation Instructions W ARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY , OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer . If you have any questions, contact the manufacturer . B. Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent p[...]
-
Page 3
3 Design Information 42” HOOD DIMENSIONS Model ZV42 I Model ZV54 I CONTENTS Design Information Product Dimensions ......................................................................3 Duct Cover Accessories ..............................................................4 Product Clearances ........................................................[...]
-
Page 4
4 Design Information DUCT COVER ACCESSORIES ZV42 I * 9" for ceiling heights 7’11" to 8’5" using the supplied support frame and duct cover . Order ZX42DC10 for ceiling heights of 8"6" to 10’4". ZV54 I * 5" for ceiling heights 7’11" to 8’5" using the supplied support frame and duct cover . Order [...]
-
Page 5
5 Advance Planning ADV ANCE PLANNING Ductwork Planning • These vent hoods are equipped for 10” round ductwork. • Determine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors. • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 150 ft. equiv[...]
-
Page 6
INST ALLA TION HEIGHT REQUIREMENTS • These vent hoods must be installed 30" min. and 36" max. above the cooking surface – regardless of the ceiling height. Therefore, installation height of the hood depends on the exact ceiling height of the kitchen. • Accessories are available for ceiling heights 8’6" and up to 10’4".[...]
-
Page 7
Use this chart to compute maximum permissible lengths for duct runs to outdoors. For best results, use 10" diameter duct. Note: Do not exceed maximum permissible equivalent lengths! Maximum recommended duct length for these hoods: 150 feet Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should b[...]
-
Page 8
8 Installation Preparation TOOLS AND MA TERIALS REQUIRED (NOT SUPPLIED) Pencil and tape measure Pliers Electric or battery operated drill and 3/16", bits, Phillips and Flat Blade Screwdriver bits. 120V 60Hz. 15 or 20 Amp, 2-wire with ground. Properly grounded branch circuit. Key Hole Saw Hammer Wire cutter/stripper Step ladder Metal Snips Sabe[...]
-
Page 9
9 Installation Preparation P ARTS PROVIDED Locate the parts packed with the hood. HARDW ARE P ACKAGE Locate and check contents. Screws shown actual size. 2 Grease trays (3 with 54" hood) Implement rods with standoffs Duct collar Support frame for 8 ft. ceiling with 4 large pan head screws installed on the bottom corners. 2-piece decorative duc[...]
-
Page 10
10 Plan the Location of the Hood and Ductwork • Use a plumb bob to check the location. The countertop/cooktop below the hood must be centered with the hood. • The hood should extend beyond the front and rear edge of the cooking appliance. • The duct in the ceiling must be centered over the cooktop. STEP 1 CONSTRUCT CEILING SUPPORT Installatio[...]
-
Page 11
11 T op View – Ceiling Joists Run Perpendicular to Front of Hood T op View – Ceiling Joists at Angle with Front of Hood Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT CONTINUED 12-3/4 ” (42 ” Hood) 17 ” (54 ” Hood) Install Cross- Framing Symmetrically About Duct/Cooktop Centerline 16 ” Joist Spacing 8 5/8 ” 10 ” Duct F[...]
-
Page 12
12 STEP 1 CONSTRUCT CEILING SUPPORT CONTINUED Installation Instructions Ductwork • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 150 feet equivalent length for any duct configuration. • Refer to “ Duct Fittings ” chart to compute the maximum permissible length for duct runs to[...]
-
Page 13
13 • Select the template for your hood size. • Align the template with the marks on the ceiling and tape in place. – Be sure the template is oriented correctly , with the front of the hood. • Use a plumb to check to be sure the mounting holes will provide parallel alignment with the countertop below . • Center punch all hole locations. ?[...]
-
Page 14
14 Installation Instructions STEP 4 INST ALL ACCESSORY (OR SUPPLIED) SUPPOR T AND DUCT COVERS Install supplied support frame OR telescoping accessory frame • Hang the supplied support frame or telescoping accessory frame to the ceiling joists and cross framing on the 4 hex head screws by engaging the keyhole slots on the frame. • Check to be su[...]
-
Page 15
15 Installation Instructions STEP 5 INST ALL DUCT TRANSITION WITH DAMPER IMPORT ANT : Remove shipping tape from damper and check that damper moves freely . • Place the transition piece over the hood exhaust and secure with 4 Screws C provided. • Use duct tape to seal the connection. Check to be sure the damper moves freely . STEP 6 INST ALL HOO[...]
-
Page 16
16 Installation Instructions STEP 8 CONNECT ELECTRICAL V erify that power is turned off at the source. W ARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer . When house wiring is aluminum, be sure to use UL approved anti-oxidant compound and aluminum-to-copper connectors. A TTENTION – Si le c â b[...]
-
Page 17
17 Installation Instructions STEP 11 INST ALL FIL TERS • Insert the filter into the upper opening and drop into the trays. • T o remove the filters, grasp the knobs and push the filter up and lift out. STEP 12 INST ALL RODS • Use a flat blade screwdriver to install stand-offs into the bottom of the hood. • Align implement rod to stand-offs [...]
-
Page 18
18 STEP 13 INST ALL SUPPLIED DUCT COVER AND TOP COVER STEP 14 FINALIZE INST ALLA TION • Check all lamps to assure tightness in sockets. • T urn power on at the circuit breaker . • Refer to the Owner ’ s Manual for operating and cleaning instructions. • Engage tabs into slots on each side at the top of the hood. The covers should lay flat [...]
-
Page 19
19 STEP 15 INST ALLA TION CHECKLIST Check Blower Safety Screw ■ ■ Ensure that blower safety screw is securely tightened. See page 16, Step 9. If screw is missing, order replacement parts bag. Check Operating Sound and Proper Air -Flow ■ ■ T urn blower to each speed setting and listen for rattles and vibration. Y ou should notice an audible [...]
-
Page 20
Pub. No. 49-80209-3 01-08 JR Note: While performing installations described in this book, safety glasses or goggles should be worn. For Monogram ® local ser vice in your area, call 1.800.444.1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change withou[...]