Go to page of
Similar user manuals
-
Portable Generator
Generac Power Systems GR160
4 pages 0.12 mb -
Portable Generator
Generac Power Systems A4021
32 pages 1.81 mb -
Portable Generator
Generac Power Systems SVP5000 97193
16 pages 0.63 mb -
Portable Generator
Generac Power Systems 1.6L 18 kW
64 pages 4.61 mb -
Portable Generator
Generac Power Systems 02010-1
64 pages 10.07 mb -
Portable Generator
Generac Power Systems 17 kW LP
192 pages 18.53 mb -
Portable Generator
Generac Power Systems GUARDIAN 04758-0
56 pages 3.94 mb -
Portable Generator
Generac Power Systems 00802-3
48 pages 2.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Generac Power Systems GUARDIAN 04758-0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Generac Power Systems GUARDIAN 04758-0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Generac Power Systems GUARDIAN 04758-0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Generac Power Systems GUARDIAN 04758-0 should contain:
- informations concerning technical data of Generac Power Systems GUARDIAN 04758-0
- name of the manufacturer and a year of construction of the Generac Power Systems GUARDIAN 04758-0 item
- rules of operation, control and maintenance of the Generac Power Systems GUARDIAN 04758-0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Generac Power Systems GUARDIAN 04758-0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Generac Power Systems GUARDIAN 04758-0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Generac Power Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Generac Power Systems GUARDIAN 04758-0.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Generac Power Systems GUARDIAN 04758-0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled A utomatic Standb y Generators Models: 04758-0 (6 kW NG, 7 kW LP) 04759-0 (12 kW NG, 12 kW LP) 04760-0 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utility or in life-support app[...]
-
Page 2
I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weather , metal enclo- sure that is [...]
-
Page 3
T able of Cont ents Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IFC How to Obtain Service ........[...]
-
Page 4
2 Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rule[...]
-
Page 5
3 ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, terminals, con- nections, etc., w[...]
-
Page 6
Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in[...]
-
Page 7
Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5 1.4 Y OU R GEN ER A T OR Control P anel Battery Compartment Fuel Regulator Air Filter Exhaust Enclosure Oil Filter Data Decal Control Panel Air Filter Exhaust Enclosure Battery Compartment Fuel Regulator Oil Filter Oil Dipstick Data Decal Figure 1.2 – 12 k[...]
-
Page 8
6 Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04758 Model 04759 Mo de l 04760 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP† Rated V oltage 120/240 120/240 120/240 Rated Max. Continuous Load Cu[...]
-
Page 9
7 1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources Board for tamper -proof dua[...]
-
Page 10
5. Remove the small brass hose fitting from the idle circuit port of the regulator housing . 6. Remove the small jet (0D5698A) located in the side of the regulator housing and install it into the small threaded hole in the idle circuit port on the regulator . 7. Refit the brass hose fitting to the idle circuit port of the regulator . Use pipe threa[...]
-
Page 11
9 1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's Auto/Off/Manual switch to OFF . 2. T urn off utility power supply to the transfer switch[...]
-
Page 12
10 The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it of f immediately with water; • Where electr olyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electrolyte is to be washed down with an [...]
-
Page 13
11 8. Connect an accurate AC voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, voltage reading should be 121- 126 volts[...]
-
Page 14
12 2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If you experience engine problems at high[...]
-
Page 15
13 Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Figure 2.3 — Engine Governor Adjustment 2.7 .2 1 2 KW AND 15 KW UN IT S 1. Loosen governor clamp bolt (See Figure 2.3). 2. Completely remove the idle spring . 3. W ith governor arm at wide open throttle position, rotate governor shaft fully clockwise. Tighten clamp[...]
-
Page 16
14 Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 8. T urn ON the utility power supply to the transfer switch, which will allow the transfer switch to transfer back to utility power . The unit will con- tinue to run for one minute and then shut down. 9. Allow the unit to cool. 10. Drain the oil and remove the oil fi[...]
-
Page 17
15 D . Utility V oltage Pickup Sensor • This sensor monitors utility power supply volt- age. When that voltage is restored to above 70 percent of the nominal source voltage, a retrans- fer time delay starts timing . E. Retransfer Time Delay • This timer runs for about 15 seconds. • At end of a 15- second delay , circuit board action de - ener[...]
-
Page 18
16 3.6 SE T TI NG TH E EXERCISE TI M ER Y our generator is equipped with an exercise timer . Once it is set, the generator will start and exercise once every seven days, on the day of the week and at the time of day you complete the following sequence. During this exercise period, the unit runs for approx- imately 12 minutes and then shuts down. Tr[...]
-
Page 19
17 4.1 F USE The generator panel’s 15 amp fuse (Figure 4.1) protects the DC control circuit against overload. The fuse is wired in series with the battery output lead to the panel. If the fuse element has melted open, you cannot crank or start the engine. Y ou should replace the fuse using only an identical 15-amp replacement. The generator panel[...]
-
Page 20
18 4.3.2 OI L CHANGE PROCEDU R E T o change the oil, proceed as follows: 1. Run the engine until it is thoroughly warmed up then shut OFF the engine. 2. Immediately after the engine shuts OFF , pull the oil drain hose (Figure 4.4) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container . Figure 4.4 – O[...]
-
Page 21
19 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 (P age 22) for maintenance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark pl[...]
-
Page 22
20 4.8 ADJ US TI NG V AL VE CLEAR ANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. Important: If you feel uncomfortable about doing this procedure or you don't have the proper tools, please contact your Generac Authorized dealer for service assistance. This is a very important step to insure long[...]
-
Page 23
21 4.1 0 A TTENTION AF TER S U B M ERSION If the generator has been submerged in water , it MUST NOT be started and operated. F ollowing any sub- mersion in water , have a Generac Authorized Dealer thor- oughly clean and dry the generator . 4.1 1 C OR ROSION P RO TECTION P eriodically wash and wax the enclosure using automo- tive type products. F r[...]
-
Page 24
22 Section 4 — Maintenance Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by your nearest Generac Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify D[...]
-
Page 25
23 Section 5 — T roubleshooting Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GUI DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables as necessary . 3. Defective sta[...]
-
Page 26
24 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00 BATTERY CUSTOMER SUPPLIED 12V HTO BLACK 86 LOP 85 IM2 1 - 20 Vac Sense Transformer L.E.D - ALARM INDICATORS 3 - 50 Hz Operation 2 - Remote Not Auto 4 - SPARE 86 RED SM IC PRINTED CIRCUIT BOARD ON - INDI[...]
-
Page 27
25 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00 CLOSEST TO BEARING 0 4 STATOR GRD 225 225 14 16 17 15 224 15 17 10 11 12 13 7 8 9 15A 0 66A 3 4 5 61 2 18 14 194 23 4 224 351 13 224A N1 225A CONNECTION MANUAL AUTO 15 15 239 13 15A 13A 17 351 351 SW1 2[...]
-
Page 28
26 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 IM1 - IGNITION MODULE, CYLINDER #1 IM2 - IGNITION MODULE, CYLINDER #2 LOP - LOW OIL PRESSURE SWITCH SP1, SP2 - SPARK PLUGS SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH SM - STARTER[...]
-
Page 29
27 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 2 15 34 J2 2 1 3 2 1 8 14 16 17 15 11 13 12 10 9 J1 7 5 6 3 4 2 1 15 0 224A 239 IM2 15A 15 18 SP2 240V IM1 0 15 194 13 17 17 15 23 15 239 SW1 194 15A N1 N2 22 11 23 11 22 11 SP1 44 POWER WINDING[...]
-
Page 30
0 4 STATOR CLOSEST TO BEARING GRD TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.) ENGINE WIRING IM - IGNITION MODULE LOP - LOW OIL PRESSURE SWITCH SP - SPARK PLUG SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH SM - STARTER MOTOR TB - INSULATED TERMINAL BLOCK BCR - BATTERY CHARGE RELAY BA - BRUSH ASSEMBLY CB1 - MAIN OUTPUT B[...]
-
Page 31
29 0 4 STATOR STATOR CLOSEST TO BEARING CLOSEST TO BEARING GRD GRD 239 MANUAL 15 AUTO 17 SW1 240V GENERATOR OUTPUT TO TRANSFER SWITCH CONTACTOR SW2 18 14 56 23 194 0 15A 13A 13 351 N1 N2 351 224 225 13 0 194 N1 N2 0 CB1 351 11 CUSTOMER CONNECTION N2 33 N1 194 23 22 44 23 55 22 33 4 224 225 13A 66A 0 4 162 REGULATOR VOLTAGE 162 22 0 6 4 11 0 4 6 224[...]
-
Page 32
IM - IGNITION MODULE LOP - LOW OIL PRESSURE SWITCH SP - SPARK PLUG SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH SM - STARTER MOTOR TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.) CB1 - CIRCUIT BREAKER, MAIN OUTPUT FS - FUEL SOLENOID F1 - FUSE 15 AMP HTO - HIGH OIL TEMPERATURE SWITCH HM - HOUR RUN METER BCR - BATTERY CHARG[...]
-
Page 33
31 2 15 34 J2 2 1 3 2 1 8 14 16 17 15 11 13 12 10 9 J1 7 5 6 3 4 2 1 224A 239 15A 0 15 18 240V IM 0 15 194 13 17 17 15 23 15 239 SW1 194 15A N1 N2 22 11 23 11 22 11 SP 44 POWER WINDING 120V 120V 33 NEUTRAL N2 N1 23 CUSTOMER CONNECTIONS 194 0 17 66A 0 SC FS 56 14 BATTERY CUSTOMER SUPPLIED SM 12V SC N2 N1 13 225 224 TX 239 56VA 1VA C2-6 C2-5 CB1 (STA[...]
-
Page 34
32 A A 51 23 36 24 37 49 35 26 47 46 49 2 43 49 43 32 33 34 18 50 7 51 4 35 25 51 15 51 48 21 1 90 91 70 93 13 49 42 39 10 3 93 25 35 14 88 54 9 8 27 35 22 51 49 50 51 49 49 11 50 16 17 51 5 47 19 12 6 31 44 47 30 29 28 87 86 41 40 55 57 56 58 52 49 20 52 72 60 44 62 48 61 64 65 66 59 67 63 45 71 69 68 71 68 69 38 58 89 73 75 46 74 76 82 78 77 80 8[...]
-
Page 35
33 ITEM P ART NO . QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE (12KW / 15KW) 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPORT , ROOF FOLDING 3 0C7061 1 ENCLOSURE, FRONT 4 0C7062 1 ENCLOSURE, EXHA UST SIDE (12KW / 15KW) 0C7062A 1 ENCLOSURE, EXHAUST SIDE (7KW) 5 0C7063 1 ENCLOSURE, SIDE & BA CK (12KW / 15KW) 0C7063A 1 ENCL[...]
-
Page 36
34 46 22 37 7 38 83 2 8, 9 27 44 47 0 13 19 14 15 35 17 49 14 15 5 3 4 16 23 36 39 38 45 48 2 28 29 17 16 4 6 7 23 27 42 12 45 44 20 40 11 1 43 35 14 30 29 28 3 41 24 4 5 47 3 1 47 45 31 3 13 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No. 0D85 03-E[...]
-
Page 37
35 ITEM P ART NO . QTY . DESCRIPTION 1 0A9947E 1 CIRCUIT BREAKER 30 X 2 240V SQD QOU230 (7KW) 0A9947G 1 CIRCUIT BREAKER 40 X 2 240V SQD QOU240 (8.5KW) 0A9947F 1 CIRCUIT BREAKER 50 X 2 240V SQD QOU250 (12KW) 0A9947C 1 CIRCUIT BREAKER 60 X 2 240V SQD QOU260 (13KW) 0A9947D 1 CIRCUIT BREAKER 70 X 2 240V SQD QOU260 (15KW) 2 0A1801 1 ASSEMBL Y , BA TTER [...]
-
Page 38
36 17 15 18 21 22 14 13 12 9 7 8 31 24 3 27 29 28 32 19 23 6 5 65 64 63 62 61 60 59 58 52 51 50 49 48 47 46 45 44 43 57 1 42 41 38 37 36 35 34 33 39 3 3 40 2 3 26 10 4 34 25 11 30 20 66 2, 5, 19, 20, 39, 40, 47, 64, 93, 140 8, 11, 12, 13 67 4, 5, 6 68 16A, 16B, 17, 18 69 7, 48, 49, 50, 51, 52, 53, 54, 55, 56, 58, 59, 60 70 48, 49, 50, 51, 52, 53, 5[...]
-
Page 39
37 ITEM P AR T NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0C3008 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 8 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0C3003 3 SEP ARA T OR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S 8 071983 4 RET AINER, PISTON P[...]
-
Page 40
38 112 112 111 108 107 106 105 104 103 102 100 109 99 92 95 96 91 89 90 89 88 86 85 83 84 82 81 130 99 118 114 126 94 93 117 79 78 76 77 75 74 122 125 123 125 119 120 137 136 134 133 132 131 127 129 135 113 101 110 121 112 128 124 124 80 87 98 97 98 97 138 139 115 116 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW a[...]
-
Page 41
39 ITEM P ART NO . QTY . DESCRIPTION 74 0C5136A 2 KNOB, AIR CLEANER 75 0C3024 1 CO VER, AIRBO X NG/LP 76 0C3040 1 PRE-CLEANER, 77 0C8127 1 ELEMENT , AIR CLEANER 78 0D8564A 1 ASSEMBL Y , MIXER/AIRBO X 990 0D8564B 1 ASSEMBL Y , MIXER/AIRBO X 760 79 0D2595 4 SCREW SHOULDER (8MM) M6-1.0 X 18 80 0D4417 4 W ASHER,R UBBER 1/4" X 1/8" THICK 81 0C[...]
-
Page 42
40 37 6 51 7 8 21 38 9 3 2 1 4 5 23 11 31 31 12 25 22 14 20 38 15 30 24 26 32 10 19 16 28 27 17 10 19 32 28 31 32 17 32 31 33 28 13 39 18 10 40 29 28 34 35 34 41 42 43 44 48 49 30 45 46 34 36 47 31 50 52 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-B[...]
-
Page 43
41 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-B ITEM P ART NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C9935H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0C6043A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8" CUR VED BLADE 6 0C9593 1 MUFFLER 7 0D3220 [...]
-
Page 44
42 36 35 37 6 34 7 8 21 38 9 3 2 1 4 5 2 11 24 31 1 2 2 5 22 14 2 0 38 1 5 30 24 2 6 32 1 0 1 9 1 6 2 8 27 17 10 19 2 8 31 3 2 17 32 31 33 2 9 2 8 1 3 39 1 8 1 0 4 0 2 9 41 42 41 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-B[...]
-
Page 45
43 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-B ITEM P ART NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C7930 1 ST A TOR 12KW 0D2359 ST A T OR 15KW 3 0C7944 1 RO TOR 12KW 0D2356 R O T OR 15KW 4 0C6043 1 CARRIER, REAR BEARING 5 [...]
-
Page 46
44 11 47 33 34 36 35 37 27 45 43 39 18 19 20 23 32 44 48 24 46 11 22 29 28 31 30 17 52 1 14 13 26 38 25 25 40 41 12 21 15 16 6 1 2 4 42 10 5 7 3 8 9 49 51 50 54 53 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-B P art 1[...]
-
Page 47
45 ITEM P ART NO . QTY . DESCRIPTION 1 071978 1 ASSEMBL Y , CONNECTING ROD 2 071980 1 PIN, PIST ON D20 3 021533 1 SET , PISTON RING 90MM 4 0C5848 1 PISTON, HC 5 071983 2 RET AINER, PISTON PIN 20 6 0D4287 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GO VERNOR RC45 8 078658 1 PIN, "R" GO VERNOR ARM 9 078659 2 W ASHER, GO VERN[...]
-
Page 48
46 20 22 6 24 23 21 29 25 3 40 41 42 43 44 2 4 1 6 6 6 5 13 7 9 8 10 11 14 15 16 17 19 12 6 38 37 36 27 28 18 26 33 18 35 34 35 18 30 31 32 39 6 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-B P art 2[...]
-
Page 49
47 ITEM P ART NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLO WER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GU ARD , F AN 5 088434 1 WRAPPER, BO TT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLO W CHROME 7 088433B 1 WRAPPER, T OP 8 0C3794 1 BUMPER, NEOPRENE 9 021544 1 ST ARTER ASSEMBL Y , EA T ON 10 0409[...]
-
Page 50
1 2 5 4 10 3 6 7 8 12 11 28 26 15 14 17 13 22 23 24 25 19 20 18 29 16 21 31 18 29 16 26 14 15 17 13 21 20 19 24 22 25 23 10 9 28 11 12 27 37 35 32 10 33 34 37 36 FOR GT 760 ENGINE ONLY 32 48 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Gas Regulator – Drawing No. 0D8 7 2 0-B[...]
-
Page 51
49 ITEM P ART NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA T OR HOUSING 2 0C5765 1 SOLENOID , TWIN REGULA T OR 3 0C4647 1 GASKET , SOLENOID 4 0C4680 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 6 022985 4 W ASHER, FLA T #6 7 022264 4 W ASHER, LOCK M4 8 075475 4 SCREW PPHM M4-0.7 X 10 9 0C5760A 1 JET , GN 410 EN[...]
-
Page 52
50 Section 8 — Mounting Dimensions Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIE W F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S Ø 3 0.2mm [ Ø 1 .19" ] R [...]
-
Page 53
51 Section 9 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators[...]
-
Page 54
52 Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators NOTE: This Emission Control W arranty Statement pertains to this product only IF the generator size is 15 kW or below . CALIFORNIA AND FEDERAL EMISSION CONTR OL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The California Air Resources Board (CARB) [...]
-
Page 55
53 Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators EMISSION CONTROL SYSTEM W ARRANTY Emission Control System Warranty (ECS W arranty) for 1997 and later model year engines: (a) Applicability: This warranty shall apply to 1997 and later model year engines. The ECS Warranty Period shall begin on the date the new engi[...]
-
Page 56
Part No. 0E1370 Revision A (07/31/02) Printed in U.S.A. Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GEN ERAC PO WER SY STEMS S T AN D AR D "T WO YEAR" LIM ITED W ARR ANT Y FOR GU AR DIAN “EM ERGENCY AUT OMA TIC S T AN DBY GENER A T ORS” F or a period of two years from the date of original sale, Ge[...]