A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Genie POWERLIFT 900, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Genie POWERLIFT 900 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Genie POWERLIFT 900. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Genie POWERLIFT 900 should contain:
- informations concerning technical data of Genie POWERLIFT 900
- name of the manufacturer and a year of construction of the Genie POWERLIFT 900 item
- rules of operation, control and maintenance of the Genie POWERLIFT 900 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Genie POWERLIFT 900 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Genie POWERLIFT 900, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Genie service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Genie POWERLIFT 900.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Genie POWERLIFT 900 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For Answers and Assistance: 1.800.354.3643 or visit www .geniecompany .com SAVE THIS MANUAL FOR FUTURE REFERENCE INST ALLER: LEAVE THIS MANUAL WITH HOMEOWNER GARAGE DOOR OPENER MODELS P owerMax ® 1200/1500, SC 1200/1500, T riloG TM 1200/1500, P owerLift ® 900, GP ower TM 900, SilentMax ® 1000/1200, CB 1000/1200, IntelliG ® 1000/1200 SCREW/BEL T[...]

  • Page 2

    Safety Information Safety Notifications .......................................... 3 Important Safety Instructions ............................ 3 Infrared Protection Function ............................. 3 Features Safety .............................................................. 4 Opener ......................................................[...]

  • Page 3

    SafetyInformation 1 OVERVIEW OF PO TENTIAL HAZARDS READ THIS SAFETY INFORMA TION CONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large, heavy objects tha t move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety o[...]

  • Page 4

    Features 2 SAFETY FEA TURES Safe-T -Beam ® (STB) Non-Contact Reversing System Puts an invisible beam across the door opening. The door stops and reverses to the full open position if anything passes through the beam. LED indicator lights on the powerhead and on the STBs provide a self-diagnostic code if an operational problem exists. Safe-T -Rever[...]

  • Page 5

    Required Programming 3 NOTE: Before you begin programming, check to make sure there are no objects in the garage door opening. INTRODUCTION Now that your Genie gara ge door opener is installed, you will want to program the opener so that the door opens and closes properly and all remote devices operate correctly . The following steps guide you thro[...]

  • Page 6

    TRA VEL LIMITS NOTE: If shuttle/bullet has NOT been enga ged to carriage, do so now . See page 17. NOTE: Before setting limits confirm wall console red indicator light (or backlight) is ON. If not illuminated, check for correct wiring or the Sure-Lock switch may be activated. Closing Garage Door (Down Limits) NOTE: Y ou have 30 seconds to execute [...]

  • Page 7

    Required Programming 3 The DOWN (closed) limit is programmed. Opening Garage Door (Up Limits) NOTE: Beginning with garage door c losed is recommended but not necessary . The UP (open) limit is programmed. BOTH DOOR LIMITS ARE NOW PROGRAMMED . PROGRAM SET PROGRAM – + 5 Press and release the Program Set button (both LEDs flash blue and go off). PRO[...]

  • Page 8

    R quired Pr ramming Required Programming 3 MODEL AC SR3 THE GENIE COMPANY FCC ID: B8Q AC SR3 Residential Door Operator IC: 2 33A-CS 1D 120V. 60HZ. 5A S/N:10XXXX XXXXXXX STB BWC IWC NOT USED NOT USED NOT USED NOT USED FROM STBs FROM W ALL CONSOLE STB BWC IWC FROM STBs FROM W ALL OM STB CONSOLE B/W W Open/Close Button Opens and closes door from insid[...]

  • Page 9

    Required Programming 3 Force and Speed Control These controls are factory programmed and automa tically set themselves when you use the Wall Console to open and c lose the garage door for the rst time. The door MUST complete a full cyc le from open to close and c lose to open before it is fully set. NOTE: Force or Speed controls DO NOT require p[...]

  • Page 10

    Required Programming 3 REMOTES / New Intellicode 2 Openers NOTE: The following instructions are for the remote control transmitters (“Remotes”) provided with this opener . This Remote is preset for use with the Intellicode 2 Access Security System. Refer to page 14 for additional information on Intellicode 1 and 2 Remotes and how to switch from[...]

  • Page 11

    The Remote button is now programmed. Repeat as necessar y for additional Remotes. T o program the same Remote for other garage door openers, repeat the steps above using one of the other two Remote buttons. Each Remote can be programmed for three door openers. BASIC PROGRAMMING IS COMPLETE AND YOUR GARAGE DOOR IS READ Y TO USE! NOTE: F or Car2U and[...]

  • Page 12

    Optional Programming 4 Setting Up a PIN 1. Press in order 3–5–7. 2. Press the Program key . 3. Enter your new PIN (3-8 characters). 4. Press Program key . Y our keypad is ready for programming. Programming Locate Y our Opener’ s Programming Buttons and LED Synchronizing Keypad to Opener 1. Press and hold Program Set key for 2 seconds. (The ro[...]

  • Page 13

    Optional Programming 4 CLEARING MEMOR Y FOR REMOTES If the memory has been cleared, the Remote will not activate the door opener . NOTE: The garage door opener will operate normally using the Wall Console. NOTE: When the remote is pressed the round LED will flash blue but will not activate the door opener . NOTE: Clearing Remotes from the P o werh[...]

  • Page 14

    INTELLICODE 1  REMOTES  Remotes provided with this unit can operate other (Intellicode® 1) models of Genie® garage door openers . The default Intellicode ® 2 setting must be changed to Intellicode® 1. (Follow these same steps to change Intellicode® 1 back to Intellicode® 2.) NOTE: Thebuttondirectlyabovethelogoont[...]

  • Page 15

    One-Piece Doors 5 A TT ACHING DOOR BRA CKET TO DOOR NOTE: Center bracket on door as high as possible, preferably top edge . A TT ACHING DOOR ARM T O DOOR BRACKET 1 Using bracket, mark holes on door or frame and drill 5/32" hole completely through door frame. Door centerline Door centerline 2 Secure bracket with 5/16" x 2" or 5/16&quo[...]

  • Page 16

    Maintenance and Adjustments 6 If you have any questions, please do not hesitate to contact customer service a t: 1-800-35-GENIE or visit www .geniecompany .com IMPOR T ANT SAFETY INSTRUCTIONS REGULAR MAINTENANCE Basic monthly maintenance tasks include: •ContactReverse •Safe-T -Beam®SystemCheck • Doorbalance • Lubric[...]

  • Page 17

    W ARNING •Useextremecautionwhenworkingfromaladderorstepstool. • Whenreplacinglightcover , makesurewiresarenotpinchedor near moving parts. Maintenance and Adjustments 6 REGULAR MAINTENANCE (continued) •  Screwdrivemodels: V erifyshuttlereleaselever?[...]

  • Page 18

    Maintenance and Adjustments 6 CAUTION Door closing force is F ACTOR Y set and requires no adjustment for normal operation. • NEVER adjust the force settings to compensate for damage, including an unbalanced door , binding door track, or broken spring. •PerformmonthlyaCONT ACTREVERSE TEST .  See page 8 . ADJUSTMENT [...]

  • Page 19

    Maintenance and Adjustments 6 ADJUSTMENT GUIDES (continued) Speed Settings (DC motors only) Speed settings are pre-programmed at the factor y for the maximum speed. Speed settings should not need adjustment with this unit. However , travel speed for the opener can be adjusted to a slower speed in both the Open and Close directions, to minimize wear[...]

  • Page 20

    Opener circuit wiring diagram. This wiring diagram is for reference only . WiringDiagram 7 1 2 3 4 5 6 1 2 3 7 6 POWERCORD CONNECTOR WHITE BLACK GREEN WHITE WHITE BLACK RED BLACK STRIPEDWHITE WALLCONSOLE SCREWDRIVEMOTOR STRIPEDWHITE SAFE-T-BEAM ® 5 4 3 2 1 (PurchasedSeparately) INTELLIGENTWALLCONSOLE 4 BLACK RED BLACK[...]

  • Page 21

    Troubleshooting 8 OPERA TION Need help or have questions? DO NOT RETURN to the store. Call us: 800-354-3643 PROBLEM WHA T TO DO Opener does NO T run from wall console. •Checkpowersource. – Plug a lamp into outlet used for powerhead. If lamp works, power source is OK. – If not, check fuse or circuit breaker . • Ifpoweris[...]

  • Page 22

    Troubleshooting 8 Powerhead LED Possible Problem Solution Round LED Long LED OFF OFF Normal operation. None required. No response from unit. Check power supply. Contact a trained door system technician. ON/RED/ STEADY ON/RED/ STEADY Limits NOT set properly. Re-program limits, see page s 6-7 . ON/RED/ FLASHING ON/RED/ FLASHING Program error. Unplug [...]

  • Page 23

    PowerMax ® 1200/1500, SC 1200/1500, TriloG ™ 1200/1500, PowerLift ® 900, GPower ™ 900, SilentMax ® 1000/1200, CB 1000/1200, IntelliG ® 1000/1200 LIMITED WARRANTY GMI Holdings, Inc d/b/a The Genie Company ("Seller") warrants to the original purchaser of the below identified, SilentMax® 1000/1200, CB 1000/1200, IntelliG® 1000/1200[...]

  • Page 24

    Looking for Leading-Edge T echnolog y or the P erfect Update/Replacement? Genie ® Has the Answer! L ea ding- Edge Techn ol og y Closed Conrm™ W ireless Remote (Works with Rev olution Series 1500, 1200 and 1000 Models) • Sleekandcompactdesign • Beepsandashesgreenwhengarage doorcloses.Givesw arni[...]