Go to page of
Similar user manuals
-
Water Pump
Giant GP8060
12 pages 0.21 mb -
Water Pump
Giant P57
8 pages 0.13 mb -
Water Pump
Giant LP123 Series
12 pages 0.37 mb -
Water Pump
Giant P219-3100
16 pages 0.47 mb -
Water Pump
Giant LP255 Series
12 pages 0.37 mb -
Water Pump
Giant P217-5100
16 pages 0.47 mb -
Water Pump
Giant P205
11 pages 0.23 mb -
Water Pump
Giant LP301A-5100
12 pages 0.56 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Giant P227-5100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Giant P227-5100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Giant P227-5100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Giant P227-5100 should contain:
- informations concerning technical data of Giant P227-5100
- name of the manufacturer and a year of construction of the Giant P227-5100 item
- rules of operation, control and maintenance of the Giant P227-5100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Giant P227-5100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Giant P227-5100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Giant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Giant P227-5100.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Giant P227-5100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Contents: Installation Instructions: page 2 Pump Specifications: pages 3- 9 Exploded View: page 10 Parts List / Kits: page 11 Torque Specifications: page 11 Repair Instructions : pages 12-13 Pump mounting selection Guide: page 13 Trouble Shooting Guide Recommened Spare Parts List: page 14 Dimensions: page 15 Warranty Information: back page Triplex [...]
-
Page 2
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pr[...]
-
Page 3
3 Specifications Model P217A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. U.S. (Metric) 1750 RPM + Ratings ......................................................... 1.8 GPM @ 2000 PSI ...... (6.8 LPM @ 137 bar) 3450 RPM + Ratings .................[...]
-
Page 4
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. Specifications Model P218A-3100/5100 U.S. (Metric) V olume ......................................................... 3.4 GPM ................... (12.5 LPM) Discharge Pressure ...................................[...]
-
Page 5
5 Specifications Model P219A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.75 5.25 1150 2.7 1.5 2.2 2.8 3.2 3.7 7.75 6.50 1450 3.5 1.9 2.9 3.6 4.1 4.8 7.75 7.25 1750 4.2[...]
-
Page 6
6 Specifications Model P220A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.75 5.25 1150 3.1 1.7 2.6 3.2 3.6 4.3 7.75 6.50 1450 3.9 2.2 3.2 4.0 4.6 5.4 7.75 7.75 1750 4.7[...]
-
Page 7
7 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil [...]
-
Page 8
8 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil [...]
-
Page 9
9 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil [...]
-
Page 10
10 Exploded View - P200A-3100/5100 Series[...]
-
Page 11
11 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301-0100 Dipstick 1 3 08302 Crankcase Plug Cover 1 3A 07190-0100 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185-0100 Oil Drain Plug with seal 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.S. 4 7 08303 Bearing Cover I 2 8 08490 Sight Glass 1 9 08492 O-Ring 1 10 07225[...]
-
Page 12
12 REPAIR INSTRUCTION - P200A-3100/5100 SERIES 1. With a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspect the o-ring (33) for wear and replace if dam- aged. 2. Using a needle nose pliers, remove the inlet and discharge valve assemblies (27-30) and o-ring (31). Inspect all parts for wear and replace as [...]
-
Page 13
13 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1 ) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). To remove the crankshaft (13), remove the bearing cover (7) and sight glass (8). Using a rubber mallet, remove the crankshaft axially through the[...]
-
Page 14
14 Preventative Maintenance Check-List & Recommended Spare Parts List Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change X X Seal Spare Parts (1 kit/pump) X (See page 11 for kit list) Oil Seal Kit (1 kit/pump) X (See pag[...]
-
Page 15
15 P200A-3100/5100 DIMENSIONS - INCHES (mm)[...]
-
Page 16
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our othe[...]