Go to page of
Similar user manuals
-
Air Conditioner
Goodman Mfg MSC/MSH 9
12 pages 0.9 mb -
Air Conditioner
Goodman Mfg RT6100004R13
69 pages 1.43 mb -
Air Conditioner
Goodman Mfg ARUF363616CA
10 pages 0.25 mb -
Air Conditioner
Goodman Mfg SS-CKF50
4 pages 0.19 mb -
Air Conditioner
Goodman Mfg ARUF182416CA
10 pages 0.25 mb -
Air Conditioner
Goodman Mfg CKLB18-1
8 pages 0.37 mb -
Air Conditioner
Goodman Mfg CKLB30-1D
8 pages 0.37 mb -
Air Conditioner
Goodman Mfg CKLB24-1E
8 pages 0.37 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg DSXC16, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg DSXC16 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg DSXC16. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Goodman Mfg DSXC16 should contain:
- informations concerning technical data of Goodman Mfg DSXC16
- name of the manufacturer and a year of construction of the Goodman Mfg DSXC16 item
- rules of operation, control and maintenance of the Goodman Mfg DSXC16 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg DSXC16 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg DSXC16, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg DSXC16.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg DSXC16 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
DRAFT SS-DSXC16 www .goodmanmfg.com 11/13 Supersedes 9/13 D S X C 1 6 S plit S yStem A ir C onDitioner U p t o 1 6 Seer C ooling C Ap ACity : 2 4,000 - 57 ,000 BtU/ h Contents Nomenclatur e ....................................... 2 Product Specica tions .......................... 3 Expanded Cooling Data ........................ 4 AHRI R atings .[...]
-
Page 2
2 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS n omenClA tUre C 4 Brand Engineering * D Goodman ® Brand Minor Revision Product Category Engineering * S Split System Major Revision Unit T ype Electrical C Condenser R-22 1 208/230 V , 1 Phase, 60 Hz X Condenser R-410A 2 220/240 V , 1 Phase, 50 Hz H Heat Pump R-22 3 208/230 V , 3 Phase, 60[...]
-
Page 3
SS-DSXC16 www .goodmanmfg.com 3 P roduct S Pecifica tionS S peCifiCA tionS DSX C16 0241AA/B DSX C16 0241AC DSX C16 0361AA/B DSX C16 0361AC DSX C16 0481B* DSX C16 0601B* Cooling Cap acity Nominal Cooling (BTU/h) 24,000 24,000 36,000 36,000 48,000 60,000 Decibels 71 71 70.4/70.9 70.4/70.9 74 75 Compre ssor RLA 10.3 11.7 16.7 15.3 21.2 28.8 LRA 52.0 5[...]
-
Page 4
4 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 675 MBh 18.0 18.7 20.4 - 17.6 18.2 20.0 - 17.2 17.8 19.5 - 16.7 17.4 19.0 - 15.9 16.5 18.1 - 14.7 [...]
-
Page 5
SS-DSXC16 www .goodmanmfg.com 5 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 675 MBh 18.6 19.0 20.3 21.7 18.2 18.6 19.9 21.2 17.8 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.5 16.8 [...]
-
Page 6
6 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 900 MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 [...]
-
Page 7
SS-DSXC16 www .goodmanmfg.com 7 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 900 MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 21.5 22.0 [...]
-
Page 8
8 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 904 MBh 24.9 25.8 28.3 - 24.3 25.2 27.6 - 23.8 24.6 27.0 - 23.2 24.0 26.3 - 22.0 22.8 25.0 - 20.4 [...]
-
Page 9
SS-DSXC16 www .goodmanmfg.com 9 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 904 MBh 25.8 26.3 28.1 30.1 25.2 25.7 27.5 29.4 24.6 25.1 26.8 28.7 24.0 24.5 26.2 28.0 22.8 23.3 [...]
-
Page 10
10 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1356 MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 30.0 31.1 34.0 - 27.[...]
-
Page 11
SS-DSXC16 www .goodmanmfg.com 11 P roduct S Pecifica tionS Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1356 MBh 35.1 35.9 38.3 41.0 34.3 35.0 37.4 40.0 33.5 34.2 36.5 39.0 32.6 33.4 35.6 38.1 31.0 31.[...]
-
Page 12
12 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60481B* / CA *f4860*6**+tXV/mBVC2 000** l ow St Age Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1238 MB[...]
-
Page 13
SS-DSXC16 www .goodmanmfg.com 13 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60481B* / CA *f4860*6**+tXV/mBVC2 000** l ow St Age ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 [...]
-
Page 14
14 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60481B* / CA *f4860*6**+tXV/mBVC2 000** h igh St Age Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1800 M[...]
-
Page 15
SS-DSXC16 www .goodmanmfg.com 15 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60481B* / CA *f4860*6**+tXV/mBVC2 000** h igh St Age ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71[...]
-
Page 16
16 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60601B* / CA *f496 1*6A *+tXV / mBV C2000**- 1** l ow S t Age Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 [...]
-
Page 17
SS-DSXC16 www .goodmanmfg.com 17 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60601B*/CA *f496 1*6A *+tXV / mBV C2000**- 1** l ow S t Age ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 6[...]
-
Page 18
18 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60601B* / CA *f496 1*6A *+tXV / mBV C2000**- 1** h igh S tA ge Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71[...]
-
Page 19
SS-DSXC16 www .goodmanmfg.com 19 P roduct S Pecifica tionS e Xp AnDeD C ooling D A t A — DSXC1 60601B*/CA *f496 1*6A*+tXV / mB VC2 000**- 1** h igh S t Age ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 [...]
-
Page 20
20 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS See Notes on Page 29. Ahri r A tingS Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0241A* A VPTC30C14A* 23,000 16,800 16.00 12.50 830 5924460 CA*F3636*6D*+EEP+TXV 24,000 17,600 14.50 12.00 820 5357193 CA*F3636*6D*+[...]
-
Page 21
SS-DSXC16 www .goodmanmfg.com 21 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0241A* (cont.) CHPF3636B6C*+TXV G*VM960604CXB* 24,000 17,600 16.00 12.50 800 5620640 CHPF3642C6C*+TXV G*VM960603B XB* 24,[...]
-
Page 22
22 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0361A* (cont.) CA*F3642*6D*+TXV G*VC950905CXB* 34,600 24,800 15.50 12.00 1,150 5620665 CA*F3642*6D*+TXV G*VC951155DXB* 34[...]
-
Page 23
SS-DSXC16 www .goodmanmfg.com 23 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0361A* (cont.) CA*F3743*6D*+TXV A*VM961005DXB* 34,000 24,400 16.00 12.50 1,150 6497674 CA*F3743*6D*+TXV G*VM960603BXB* 34[...]
-
Page 24
24 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0361A* (cont.) CHPF3642C6C*+MBVC1600**-1A*+TXV 34,600 24,800 16.00 12.50 1,200 3654024 CHPF3642C6C*+TXV G*VC80604B*B* 34,[...]
-
Page 25
SS-DSXC16 www .goodmanmfg.com 25 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0361A* (cont.) CHPF3743C6B*+TXV A*VM960805D XB* 34,600 24,800 16.00 12.00 1,150 6497710 CHPF3743C6B*+TXV G*VC80805C*B* 34,600 24,800 16.00 12.5[...]
-
Page 26
26 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0361A* (cont.) CHPF4860D6D*+TXV G*VM960603BXB* 34,600 24,800 16.00 12.50 1,130 5620693 CHPF4860D6D*+TXV G*VM960805CXB* 35[...]
-
Page 27
SS-DSXC16 www .goodmanmfg.com 27 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0481B* (cont.) CA*F4860*6D*+TXV G*VC950905DXB* 46,000 34,600 16.00 12.30 1,400 5620750 CA*F4860*6D*+TXV A*VM961005DXB* 46[...]
-
Page 28
28 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) See Notes on Page 29. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furna ces T ot al¹ Sens.¹ SEER² EER³ DSX C16 0481B* (cont.) CHPF4860D6D*+TXV G*VM961155DXB* 47,000 35,200 16.00 12.30 1,350 5620772 CHPF4860D6D*+TXV G*VC950905DXB* 47[...]
-
Page 29
SS-DSXC16 www .goodmanmfg.com 29 P roduct S Pecifica tionS Ahri r A tingS ( Cont .) [...]
-
Page 30
30 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS DSX C160241A* 26 26 32¼ DSX C160361A* 29 29 38¼ DSX C160481B* 35½ 35½ 36¼ DSX C160601B* 35½ 35½ 38¼ D imenSionS[...]
-
Page 31
SS-DSXC16 www .goodmanmfg.com 31 P roduct S Pecifica tionS w iring D iAgrAm Wiring is subject to change. Alw ays ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning Disconnect all power before servicing or installing this unit. Mulple power sources may be present. Failu[...]
-
Page 32
32 www .goodmanmfg.com SS-DSXC16 P roduct S Pecifica tionS Goodman Manufacturing Company , L.P ., reserves the right to discontinue, or change at any time, specica tions or designs without notice or without incurring obligations. © 2013 • Goodman Manufacturing Company , L.P . • Houston, T exas • Printed in the USA. A CCeSSorieS ?[...]