Goodman Mfg SSZ 14 SEER manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg SSZ 14 SEER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg SSZ 14 SEER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg SSZ 14 SEER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodman Mfg SSZ 14 SEER should contain:
- informations concerning technical data of Goodman Mfg SSZ 14 SEER
- name of the manufacturer and a year of construction of the Goodman Mfg SSZ 14 SEER item
- rules of operation, control and maintenance of the Goodman Mfg SSZ 14 SEER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg SSZ 14 SEER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg SSZ 14 SEER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg SSZ 14 SEER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg SSZ 14 SEER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SSZ 14 SEER S plit System Heat Pump s • Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. RT6213005 Rev. 3 August 2010 Cop[...]

  • Page 2

    PRODUCT IDENTIFICA TION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause p[...]

  • Page 3

    PRODUCT IDENTIFICA TION 3 The United States Environmental Protection Agency (“EPA”) has issued various regulations re- garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by ju[...]

  • Page 4

    PRODUCT DESIGN 4 SSZ14 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then dis- charged out of the top of the cabinet. These units are designed for[...]

  • Page 5

    HEA T PUMP SPECIFICA TIONS 5 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial[...]

  • Page 6

    HEA T PUMP SPECIFICA TIONS 6 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/ circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. S S Z 140181AF S S Z 140241AJ S S Z 140301AF S S Z 140361AH S S Z 140421AF S S Z 140481AF S S Z[...]

  • Page 7

    7 COOLING PERFORMANCE DA T A SSZ140181A* EXP AN DE D PE RFORM ANCE DA T A C OOL I N G OP E R A TION M O DE L : S S Z 1 40181A* / CA*F 3131*6A* + TX V / M BR800** - 1 O ut door Am bi e nt Te m per at ure 65 75 8 5 95 105 115 E nter i ng I ndo or Wet B u lb Te m pe rat ure I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 [...]

  • Page 8

    8 COOLING PERFORMANCE DA T A SSZ140181A* EXP AN DE D PERF O RM ANCE DA T A C OOL I N G OP E R ATION M O DE L : S S Z 1 40181A* / CA*F 3131* 6A* + T X V / M BR8 00**-1 O ut door Am bi e nt Tem pe ra ture 65 75 8 5 95 105 115 E nter i ng I ndoor W e t B u lb Te m pe rat ur e I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 9[...]

  • Page 9

    9 COOLING PERFORMANCE DA T A SSZ140241A* EXPANDED PERF O RM ANCE DA T A C OOL I N G OP E R ATIO N M O DE L : S S Z 14 0241A* / CA*F3 636*6A*+ T X V / M B R800**-1 O utdoor Am bi e nt Te m pe r ature 65 75 85 95 105 1 15 E nte ring I ndoor We t B ulb Te m pe r ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 36 77 [...]

  • Page 10

    10 COOLING PERFORMANCE DA T A SSZ140241A* EX PANDED P ERF ORM ANCE DAT A C OOL IN G OP E R ATION M ODEL: S S Z 140241A* / CA*F3636*6A*+ T X V / M BR800**-1 O utdoor Am bi e nt Tem pe r ature 65 75 85 95 105 115 E nte r ing I ndoor We t B ul b Te m pe r ature I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 36 77 15 96 3[...]

  • Page 11

    11 COOLING PERFORMANCE DA T A SSZ140301A* EXPA NDED PERFO RM ANC E DA T A C OOLI N G OP E R ATI O N M O D EL: S S Z 140301A* / CA*F 3642*6A*+T X V / M BR1600**- 1 O utdoo r Am bi e nt Te m pe ra ture 65 75 85 95 105 11 5 E nte r ing I ndoor We t B ul b Te m pe r a ture I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15 96 [...]

  • Page 12

    12 COOLING PERFORMANCE DA T A SSZ140301A* EX PANDED PERF O RM ANCE DAT A C O O L IN G O P E R A T IO N M O D EL: S S Z 140301A* / CA*F 3642*6A*+ TX V / M BR1600**-1 O utdoo r Am bi e nt T e m pe ra ture 65 75 85 95 105 115 E nte r i ng Indoo r We t B ul b Te m pe r at ure I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15 [...]

  • Page 13

    13 COOLING PERFORMANCE DA T A SSZ140361A* EXPA N DED PER FORM AN CE D ATA M ODEL: S S Z 140361A* / CA* F 4860*6A*+ TX V / M BR1600* *-1 O utdoo r Am bie nt Te m pe r a tur e 65 75 85 95 105 115 E n t e r in g In d o o r We t B u lb T e m pe r at u r e ID B Air flo w 5 9 63 67 71 59 6 3 67 71 59 63 67 71 59 63 67 71 59 63 67 71 5 9 63 67 71 M Bh 33.[...]

  • Page 14

    14 COOLING PERFORMANCE DA T A SSZ140361A* EX PANDED PE RF O RM ANCE DATA C OOL IN G OP E R AT ION M ODEL: S S Z 140361A* / CA* F 4860*6A*+ TX V / M BR1600* *-1 O utdoor Am bie nt Te m pe r a tur e 65 75 85 95 105 115 E nter ing I nd oor Wet B u l b T e m pe r ature I D B * A i r f l o w 5 9 6 3 6 77 1 5 9 6 36 7 7 1 5 9 6 3 6 77 15 9 6 3 6 7 7 15 9[...]

  • Page 15

    15 COOLING PERFORMANCE DA T A SSZ140421A* EXPAN DED PERFORMAN CE DATA M ODEL : S S Z140421A* / CA*F 4860*6 A*+ T X V / M BR 2000**-1 O utdoor Am bi e n t Te m p e rature 65 75 85 95 105 115 E nte r ing I ndoo r We t B ulb Te m pe r atur e ID B A ir flo w 59 63 67 71 59 63 67 71 5 9 63 67 71 59 63 67 71 59 63 6 7 71 59 63 67 71 M Bh 39. 2 40.6 4 4.5[...]

  • Page 16

    16 COOLING PERFORMANCE DA T A SSZ140421A* EXPA NDED PER F O RM AN CE DA TA C OOL I N G OP E R AT I ON M O DE L : S S Z140421A* / CA*F 4860*6 A*+ TX V / M BR2000* *- 1 O u tdoor Am bi e n t Te m pe r ature 65 75 85 95 105 115 E nte r ing I ndoo r We t B ulb Te m pe r atur e I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7 15[...]

  • Page 17

    17 COOLING PERFORMANCE DA T A SSZ140481A* EXPA ND ED PER FOR M AN CE D ATA C OOL I N G OP E R ATIO N M O DEL: S S Z 14 0481A* / CA*F 4860*6A* + T X V / M BR20 00**-1 O u tdoor Am bi e n t Te m pe rature 65 75 85 95 105 115 E n te r ing Ind o o r We t Bulb T e m p e r at u r e I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6 7 7[...]

  • Page 18

    18 COOLING PERFORMANCE DA T A SSZ140481A* EXPA ND ED PER FO RM AN CE D ATA C OOLIN G OP E R AT I O N M O DEL: S S Z 14 0481A* / CA*F 4860* 6A*+ T X V / M BR2000* *-1 O utdoor Am bi e n t Te m pe rature 65 75 85 95 105 115 E n te r in g In d o o r W e t B u lb Te m p e r a t u r e I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 9 6 3 6 77 15 9 6 3 6[...]

  • Page 19

    19 COOLING PERFORMANCE DA T A SSZ140601A* EXP AND E D PERF O RM A NCE DATA C OOL I N G OP E R ATION M O DE L: S S Z 140601 A* / CA*F4860*6 A*+ T X V / M BE2 000**- 1 O utdoor A m bi e nt Te m pe r a ture 65 75 8 5 95 105 115 E nter i ng I ndoor W e t B ul b Te m p e ra ture ID B Air flow 59 63 67 71 5 9 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 [...]

  • Page 20

    20 COOLING PERFORMANCE DA T A SSZ140601A* EXP AND E D PERF ORM ANCE DAT A C OOL I N G OP E R ATION M ODEL: S S Z 140601A* / CA*F4860*6A *+ TX V / M BE 2000**- 1 O utd oor Am bi e nt Te m pe ra ture 65 75 8 5 95 105 115 E nter i ng I ndoor W e t B ul b Te m peratu r e I D B * A i r f l o w 5 96 36 77 15 96 36 77 15 96 36 77 15 9 6 3 6 7 7 15 96 36 7[...]

  • Page 21

    21 PERFORMANCE DA T A Out door Temp. ° F . Total Btuh Sensible Btu h La te nt Btuh Total Wat ts 75° 36,330 24,713 11,617 2,662 80° 35,898 24,729 11,169 2,742 85° 35,465 24,738 10,727 2,822 90° 35,033 24,830 10,203 2,892 95° 34,600 24,912 9,688 2,963 100° 33,735 24,749 8,986 3,0 23 105° 32,870 24,563 8,307 3,0 83 110° 31,659 23,757 7,902 3,[...]

  • Page 22

    22 EXPA NDED PERFORM A NCE DATA M ODEL: SSZ140361A * / CA*F4860C6A *+TXV / M BR1600**-1 HEATING O PERATION Outdoo r Ambient Tem p era ture 65 60 55 50 47 45 40 35 30 25 2 0 17 15 10 5 0 -5 -10 MBh 4 3.5 41.2 38.8 36.2 34.6 33.5 31 .1 28.7 28.8 26.6 24.5 23. 1 22 .3 20.0 17.7 1 5.5 13.2 10.8 Delta T 38.4 36.3 34.2 31.9 30.5 29. 6 27.5 25.3 2 5.4 23.[...]

  • Page 23

    23 EXPANDED PERFORM ANCE DA TA MO DEL: SSZ140481A* / CA*F4860*6A *+TXV / MBR2000**-1 HEA T ING OPERATION Outdoor Ambie nt Temperat ure 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 - 5 -10 MBh 57.8 5 4.7 5 1.5 48. 2 46.0 4 4.6 41.4 38.2 36 .6 33.8 31.1 29. 4 28.3 25.4 22. 5 19.6 16.8 13. 7 D e l t a T 3 4 . 53 2 . 73 0 . 82 8 . 8 2 7 . 5 2 6 . 62 4[...]

  • Page 24

    24 HEA TING SPECIFICA TIONS capacit y btuh c.o.p. 4.8 9.6 1 4.4 19. 2 65 22.63 4.23 39.01 55.39 71.77 88.16 60 21.42 4.09 37.80 54.18 70.57 86.95 55 20.16 3.93 36.54 52.92 69.31 85.69 50 18.85 3.75 35.23 51.61 67.99 84.38 45 17.44 3.54 33.82 50.21 66.59 82.97 40 16.20 3.36 32.58 48.96 65.35 81.73 35 14.94 3.16 31.32 47.70 64.09 80.47 30 12.80 2.70 [...]

  • Page 25

    25 HEA TING SPECIFICA TIONS capaci t y btuh c. o. p. 4 .8 9.6 14. 4 19. 2 65 51.5 4 4 .44 67 .92 84. 30 100. 68 117. 07 60 48.7 9 4 .28 65 .17 8 1. 55 97. 94 114. 32 55 45.9 2 4 .11 62 .30 7 8. 68 95. 07 111. 45 50 42.9 3 3 .92 59 .31 7 5. 69 92. 07 108. 46 45 39.7 3 3 .70 56 .11 7 2. 49 88. 88 105. 26 40 36.9 0 3 .50 53 .28 6 9. 66 86. 05 102. 43 [...]

  • Page 26

    26 PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a [...]

  • Page 27

    WIRING DIAGRAMS 27 HIGH VOL T AGE! DIS CONNECT ALL POWER BEFORE SERVICING OR INST A LLIN G THIS UNIT . MUL T IPLE POW ER SOURCES MA Y BE PRESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY DAMAGE, PERSONAL I NJURY OR DEA TH . Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. SSZ140[18,30,42-60[...]

  • Page 28

    WIRING DIAGRAMS 28 HIGH VOL T A GE! DISCO NNECT A LL POWE R BEFORE SERVICI NG OR INS T A LLIN G THIS UNIT . M UL T IPLE POW ER SOURCES MA Y BE PRESENT . F AI LURE TO DO SO MA Y C AUS E PROP ERTY DAMAG E, PERSONAL I NJURY OR DE A TH . USE N.E .C. CL ASS 2 WI R E NOTES: 1) TO INDO OR UNI T LO W VOLT A GE TER M IN AL BLOC K & IN DO O R T H E R MO [...]