Goodman Mfg SSZ140181A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Goodman Mfg SSZ140181A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman Mfg SSZ140181A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Goodman Mfg SSZ140181A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Goodman Mfg SSZ140181A should contain:
- informations concerning technical data of Goodman Mfg SSZ140181A
- name of the manufacturer and a year of construction of the Goodman Mfg SSZ140181A item
- rules of operation, control and maintenance of the Goodman Mfg SSZ140181A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman Mfg SSZ140181A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman Mfg SSZ140181A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman Mfg service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman Mfg SSZ140181A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman Mfg SSZ140181A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SSZ 14 SEER S plit System Heat Pumps • Refer to Service Manual RS6200005 for installation, op- eration, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. RT6213005 May 2006 TECHNICAL INFORMA TION MANUAL Copyright ?[...]

  • Page 2

    PRODUCT IDENTIFICA TION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. WARNING WARNING WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to d[...]

  • Page 3

    PRODUCT IDENTIFICA TION 3 WARNING WARNING WARNING WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serio[...]

  • Page 4

    PRODUCT DESIGN 4 SSZ14 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then dis- charged out of the top of the cabinet. These units are designed for[...]

  • Page 5

    HEA T PUMP SPECIFICA TIONS 5 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial[...]

  • Page 6

    6 COOLING PERFORMANCE DA T A SSZ140181A* EXPA NDED PERFORMAN CE DA TA COOLING OPE RA TION MODEL: SSZ140181A * / CA *F3131*6 A* +TXV / M BR800**-1 D esign Subcooling 9 ± 3 °F @ the liqui d service valve, A RI 95 test conditio ns Outdoor A mbient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature I D B * A i r f l o w 5 96 36 77 1[...]

  • Page 7

    7 COOLING PERFORMANCE DA T A SSZ140181A* EXPA NDED PERFORMAN CE DATA COOLING O PERATION MODEL: SSZ140 181A * / CA *F3131*6A * +TXV / M BR800**-1 D esign Subc ooling 9 ±3 °F @ t he liquid service v alve, A RI 95 test c onditio ns Outdoor A mbient Temperature 65 75 85 95 105 115 Entering Indoor W et Bulb Temperatur e I D B * A i r f l o w 5 96 36 7[...]

  • Page 8

    8 COOLING PERFORMANCE DA T A SSZ140241A* EXPA ND ED PERFORM A NCE DATA COOLING OP ERA TION MODEL: SS Z140241A * / CA *F3636*6 A *+TXV / MBR80 0**-1 Design Subco oling 9 ±3 °F @ the liquid service val v e, A RI 95 tes t condition s Outdoor A mbient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperatur e I D B * A i r f l o w 5 96 3 6[...]

  • Page 9

    9 COOLING PERFORMANCE DA T A SSZ140241A* EXPA NDED PERFO RMA NCE DA T A COOLING OPERA TION MO DEL: SSZ140241A* / CA *F3636* 6A *+TXV / MB R800**-1 Design Subcoo ling 9 ±3 °F @ the liqui d service valv e, ARI 95 test condit ion s Out door A mbient Temp eratur e 65 75 85 95 105 115 Enteri ng I ndoor W et Bulb Temperatur e I D B * A i r f l o w 5 96[...]

  • Page 10

    10 COOLING PERFORMANCE DA T A SSZ140301A* EXPA NDED PERFORMA NCE DA TA COOLING OPERA TION M ODEL: SSZ140301A* / CA *F3642*6A*+TXV / MBR1600**-1 Design Subcooling 9 ±3 °F @ the liquid service valv e, AR I 95 test conditio ns Outdoor A mbient Temperature 65 75 85 95 105 1 15 Enterin g Indo or W et Bul b Temperatur e I D B * A i r f l o w 5 96 36 77[...]

  • Page 11

    11 COOLING PERFORMANCE DA T A SSZ140301A* EXPA NDED PERFORMA NC E DA TA COOLING OPERA TION M ODEL: SSZ 140301A * / CA*F3642*6A *+T XV / MB R1600**-1 Design Subcooling 9 ±3 °F @ th e liquid serv ice valve, ARI 95 test conditio ns Outdoor A mbi ent Temper atu re 65 75 85 95 105 115 Enterin g Indo or W et Bulb Temperature I D B * A i r f l o w 5 96 [...]

  • Page 12

    12 COOLING PERFORMANCE DA T A SSZ140361A* EXPA NDED PER FOR M A NCE DA T A MODEL: SSZ140 361A * / CA*F4860*6A*+TXV / M BR1600 **- 1 Desig n Subco oli ng 9 ±3 ° F @ th e li qu id serv i ce va lv e, A RI 95 t est co ndi ti o ns Outdo or A mbient T emperature 65 75 85 9 5 105 115 Entering I ndoor Wet Bulb Te mperature IDB Airfl ow 59 63 67 71 59 63 [...]

  • Page 13

    13 COOLING PERFORMANCE DA T A SSZ140361A* EXPA ND ED PERFO RM A NCE D A TA COOLING OP ERATION MODEL: SSZ140361A* / CA *F4860*6A*+TXV / M BR1600 **- 1 Desig n Subco oli ng 9 ±3 ° F @ th e li qu id serv i ce va lv e, A RI 95 te st cond it i o ns Outdo or A mbient T emper ature 65 75 85 9 5 105 115 Entering I ndoor Wet Bulb Te mperature I D B * A i [...]

  • Page 14

    14 COOLING PERFORMANCE DA T A SSZ140421A* EXPA NDED PERFORMA NCE DA T A MODEL: S SZ1404 21A * / CA *F4860*6 A*+TXV / M BR2000 **-1 Design Sub cooling 9 ±3 °F @ the li quid service valve, A RI 95 test conditio ns Outdoor A mbient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature IDB A irf lo w 59 63 67 71 59 63 6 7 71 59 63 67 7[...]

  • Page 15

    15 COOLING PERFORMANCE DA T A SSZ140421A* EXPANDED PERFORMANCE DA T A COOLING OP ERA TION MODEL: SSZ14 0421A * / CA *F4860*6A *+TXV / MBR2000 **-1 Design Sub cooli ng 9 ±3 °F @ the liquid s ervice valve, A RI 95 test condi t io ns Outdoor A mbient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature I D B * A i r f l o w 5 96 36 7[...]

  • Page 16

    16 COOLING PERFORMANCE DA T A SSZ140481A* EXPA NDED PERFORMANCE DA TA COOLING O PERA TION MODEL: SS Z140 481A * / CA *F48 60*6A *+TXV / MBR20 00**-1 Design Sub cooling 9 ±3 °F @ the liq uid service va lve, A RI 95 test con ditio ns Outdoor A mbient Temperatur e 65 75 85 95 1 05 115 Entering Indoor Wet Bulb Te mperature I D B * A i r f l o w 5 96 [...]

  • Page 17

    17 COOLING PERFORMANCE DA T A SSZ140481A* EXPA NDED PERFORMA NCE DATA COOLING O PERA TI ON MODEL: S S Z140481 A* / C A*F4 860*6A *+TXV / MBR2000**-1 Design S ubcool ing 9 ±3 °F @ the liquid s ervice valve, A RI 95 tes t conditio ns Outdoor A mbient Temperature 65 75 85 95 1 05 115 Entering Indoor Wet Bulb Temperatur e I D B * A i r f l o w 5 96 3[...]

  • Page 18

    18 COOLING PERFORMANCE DA T A SSZ140601A* EXPA NDED PERFORMA N CE DA TA COOLING O PERATION MODEL: SSZ140 601A * / CA *F4860*6A *+TXV / MBE200 0**-1 Design S ubcooling 9 ±3 ° F @ the liquid s ervice valve, A RI 95 test conditio ns Outdoor A mbie nt Temperat ure 65 75 85 9 5 105 115 Entering Indoor W et Bulb Temperature IDB A irf lo w 59 63 67 71 5[...]

  • Page 19

    19 COOLING PERFORMANCE DA T A SSZ140601A* EXPA NDED PERFORMA NCE DAT A COOLING O PE RA TI ON MODEL: SSZ140 601A * / CA *F4860*6 A *+TXV / MBE2000** -1 Design Subcooling 9 ±3 ° F @ the liquid service valve , A RI 95 test conditio ns Outdoor A mbie nt Temperat ure 65 75 85 9 5 105 115 Entering Indoor W et Bulb Temperature I D B * A i r f l o w 5 96[...]

  • Page 20

    20 PERFORMANCE DA T A Out door Temp. ° F . Tota l Btuh Sen sibl e Btu h La te nt Btuh Total Wat ts 75° 36,330 24,713 11,617 2,662 80° 35,898 24,729 11,169 2,742 85° 35,465 24,738 10,727 2,822 90° 35,033 24,830 10,203 2,892 95° 34,600 24,912 9,688 2,963 100° 33,735 24,749 8,986 3,023 105° 32,870 24,563 8,307 3,083 110° 31,659 23,757 7,902 3[...]

  • Page 21

    21 EXPA NDED PERFORM ANCE DA TA M ODEL: SSZ140361A * / CA*F4860C6A *+T XV / M BR1600**-1 HEATING O PERATION Outdoo r Ambient Tem p era ture 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 43.5 41.2 38.8 36.2 34.6 33.5 31. 1 28.7 28.8 26.6 24.5 23. 1 22. 3 20.0 17.7 1 5.5 13.2 10.8 Delta T 38.4 36.3 34.2 31.9 30.5 29.6 27.5 2 5.3 2 5.4 23.5[...]

  • Page 22

    22 EXPANDED PERFORM ANCE DA TA MO DEL: SSZ140481A* / CA*F4860*6A *+TX V / MBR 2000**-1 HEA T ING OP ERATION Outdoor A mbient Te mperat ure 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -1 0 MBh 57.8 5 4.7 5 1.5 48. 2 46. 0 44.6 41 .4 38.2 36 .6 33 . 8 31.1 29. 4 28.3 25 .4 22 .5 19.6 16. 8 13.7 D e l t a T 3 4 . 53 2 . 73 0 . 8 2 8 . 8 2 7 . 5 2[...]

  • Page 23

    23 HEA TING SPECIFICA TIONS capacit y btuh c.o.p. 4.8 9.6 1 4.4 19.2 65 22.63 4.23 39.01 55.39 71.77 88.16 60 21.42 4.09 37.80 54.18 70.57 86.95 55 20.16 3.93 36.54 52.92 69.31 85.69 50 18.85 3.75 35.23 51.61 67.99 84.38 45 17.44 3.54 33.82 50.21 66.59 82.97 40 16.20 3.36 32.58 48.96 65.35 81.73 35 14.94 3.16 31.32 47.70 64.09 80.47 30 12.80 2.70 2[...]

  • Page 24

    24 HEA TING SPECIFICA TIONS capaci t y btuh c. o.p . 4. 8 9. 6 14.4 19 . 2 65 51.5 4 4. 44 67. 92 84. 30 1 00. 68 117. 07 60 48.7 9 4. 28 65. 17 81. 55 9 7.9 4 114 .32 55 45.9 2 4. 11 62. 30 78. 68 9 5.0 7 111 .45 50 42.9 3 3. 92 59. 31 75. 69 9 2.0 7 108 .46 45 39.7 3 3. 70 56. 11 72. 49 8 8.8 8 105 .26 40 36.9 0 3. 50 53. 28 69. 66 8 6.0 5 102 .4[...]

  • Page 25

    25 PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a [...]

  • Page 26

    WIRING DIAGRAMS 26 TO AVOID POSSI BLE ELECTRICAL SHOCK, PERSONAL INJURY, OR DEATH, DI SCONNECT THE POWER BEFORE SERVI CING. WARNING ! Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. SSZ140[18-60]1A* COM P IO T1 C M A I N R A U X 5 S SR SA 2 1 RCCF SC T2 C L1 L2 C H C F M A I N A U X IO CM [...]