Go to page of
Similar user manuals
-
Furnace
Goodman GHS80453AXCA
10 pages 0.42 mb -
Furnace
Goodman GMS90453BXA
11 pages 0.28 mb -
Furnace
Goodman GDS80453AXCA
10 pages 0.34 mb -
Furnace
Goodman ACVC90704CXAA
12 pages 0.26 mb -
Furnace
Goodman AMV8
32 pages 1.31 mb -
Furnace
Goodman UPFLOW/HORIZONTAL GME8
16 pages 0.31 mb -
Furnace
Goodman GKS90453BXAA
11 pages 0.25 mb -
Furnace
Goodman CVC9/95
60 pages 1.42 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Goodman GKS9, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman GKS9 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Goodman GKS9. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Goodman GKS9 should contain:
- informations concerning technical data of Goodman GKS9
- name of the manufacturer and a year of construction of the Goodman GKS9 item
- rules of operation, control and maintenance of the Goodman GKS9 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman GKS9 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman GKS9, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman GKS9.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman GKS9 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
C US ® Copyright © 2006-2007, 2009 Goodman Manufacturing Company, L.P. This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. • Refer to Service Man[...]
-
Page 2
PRODUCT IDENTIFICA TION 2 Furnace Type S : Single Stage/Multi-Speed The model and manufacturing number are used for positive identification of component parts used in manufacturing. When engineering and manufacturing changes take place where interchangeability of components are affected, the manufactur- ing number will change. It is very important [...]
-
Page 3
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. When engineering and manufacturing changes take place where interchangeability of components are affected, the manufactur- ing number will change. GKS90453BX* GKS90703BX* GKS90704CX* GKS90904CX* GKS90905DX* GKS[...]
-
Page 4
4 PRODUCT DESIGN 2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace. 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fitt[...]
-
Page 5
5 COMPONENT IDENTIFICA TION 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Combustion Air Intake Connection / “Coupling” 4 Hot Surface Igniter 5 Burners 6 Rollout Limit 7 Flame Sensor 8 Flue Pipe Connection / “Coupling” 9 Flue Pipe (Internal) 1 0 Primary Limit 1 1 Pressure Switch 1 2 Gas Line Entrance 1 3 Rubber Elbow 1 4 Flue Pipe Connectio[...]
-
Page 6
COMPONENT IDENTIFICA TION 6 GKS9 NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues. Cabinet Size A B C D E 13-5/8 17-1/2 20-7/8 All dimensions are in inches. GKS90453BX* GKS90703BX* GKS90704CX * GKS90904CX * GKS90905DX * GKS91155DX * 16 19-1/2 23 17-1/2 21 [...]
-
Page 7
7 PRODUCT DESIGN * GKS9 furnaces are shipped without coil cover pressure switches. All GKS9 models are shipped from the factory as Dedicated Upflow but can be installed as a Horizontal Left or a Horizontal Right, ONLY after installing GKS9 Horizontal Installation Kit 0270K00012, which contains Pressure Switch 20197312. GKS90 453BX* -1.4 0 -1.20 -0.[...]
-
Page 8
8 PRODUCT DESIGN Part Numbe r 20162903 20162904 20162906 Open Setti ng (°F) 160 150 170 GKS90453B X* 1 GKS90703B X* 1 GKS90704C X* 1 GKS90904C X* 1 GKS90905D X* 1 GKS91155D X* 1 T.O.D. PRIM ARY LIMIT Part Number 10123514 or 10123533 Open Se tting (°F) 200 GKS90453BX* 1 GKS90703BX* 2 GKS90704CX* 2 GKS90904CX* 2 GKS90905DX* 2 GKS91155DX* 2 ROLLOUT [...]
-
Page 9
9 PRODUCT DESIGN Coil Matches: Coil Matches (for Goodman ® unit s using R22 and R-410A): • All CAPF coils in B, C, & D widths have insulated blank off plates for use with one size smaller furnaces. • All CAPF coils have a CAUF equivalent. • All CHPF coils in B, C & D heights have an insulated Z bracket for use with one size smaller f[...]
-
Page 10
10 PRODUCT DESIGN Thermost ats: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This f[...]
-
Page 11
FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altit[...]
-
Page 12
BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3. For[...]
-
Page 13
BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 11 0 12 0 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTP UT BT U/HR x 1 000 BTU OUTPU T vs TEMPERAT URE RISE CHART T EM P ER AT U R E R I SE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CF M x 1 .08 x RISE RISE = BTU OUTP UT 1.08 ÷ CFM 800[...]
-
Page 14
14 WIRING DIAGRAMS HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL I NJUR Y OR DE A TH . Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GKS9*****X** [...]