Go to page of
Similar user manuals
-
Heat Pump
Goodman RP-526A
13 pages 0.33 mb -
Heat Pump
Goodman GSZ/VSZ 13 SEER
55 pages 0.74 mb -
Heat Pump
Goodman GPH1324M41AB
12 pages 0.38 mb -
Heat Pump
Goodman GSZ11
9 pages 0.46 mb -
Heat Pump
Goodman GSH 10 SEER
9 pages 0.3 mb -
Heat Pump
Goodman SSZ 14 SEER
39 pages 0.58 mb -
Heat Pump
Goodman R-410A
47 pages 1.54 mb -
Heat Pump
Goodman GSC140481A
25 pages 0.88 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Goodman RP-526A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Goodman RP-526A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Goodman RP-526A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Goodman RP-526A should contain:
- informations concerning technical data of Goodman RP-526A
- name of the manufacturer and a year of construction of the Goodman RP-526A item
- rules of operation, control and maintenance of the Goodman RP-526A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Goodman RP-526A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Goodman RP-526A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Goodman service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Goodman RP-526A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Goodman RP-526A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Light Commercial 3 - 6 Ton Belt Drive Packaged Heat Pumps REPAIR PARTS RP-526A This manual is to be used by qualified technicians only. www.goodman mfg.com www.am ana-hac.com This manual replaces RP-526 © 2008-2009 Goodman Manufacturing Company, L.P. ◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 April 2009 CPH036 XXX3BXJ XB A CPH036XXX3BXXX[...]
-
Page 2
Important Informatio n For assistance within the U.S.A. contact: International Divisi on Goodman Company, L.P. 7401 Security Way Housto n, Texa s 77040 713-861-2500-Telephone 713-863-2382-Facsimile For assistance outside the U.S.A. contact: Index Functi onal Par ts List This system uses R410A refrigera nt. If seale d system work is required, use ap[...]
-
Page 3
Functional Parts Part No: Description: 0130M00025S 24V RELAY (M3, M4, M7, M 8, M9, M 10, M13, M14, M 15, M 16, M19, M20, M 21, M22) PCBFM103S BOARD , ELECTRONIC BLOW ER TIME DELA Y RELAY CAP050000370VA S CAPA CITOR 5/370V ZP31K5ET F5830 COMPRESS OR 31200, 200/230/60/3 (M1, M 2) ZP31K5ET FD830 COMPRESS OR 31200, 460/60/3 (M3, M 4) ZP39K5ET F5830 COM[...]
-
Page 4
Top Panel/Tub i ng Assy 4 RP-526 A www. goodm anm fg.com www. am a na -ha c .c om[...]
-
Page 5
Top Panel/Tubing Assy Ref. No: Part No: Description: Ref. No: Part No: Descri ption: Image 1: INSULATED ASSY, TOP PANEL 0270L00086S 11 COND MOTOR 1/3 HP, 1 SP, 6 PL (M17, M18) 0131M00008PS 21 COND MOTOR 1/3 HP, 460V (M19, M20) B13400249S 21 COND MOTOR 1/4 HP, 1 SP, 6 PL (M1, M2, M5, M6, M11, M12) 0131M00007PS 21 COND MOTOR 380/460 50/60 CYCLE (M3, [...]
-
Page 6
Cabinet A ssy 6 RP-526 A www. goodm anm fg.com www. am a na -ha c .c om[...]
-
Page 7
Cabinet Assy Ref. No: Part No: Description: Ref. No: Part No: Descri ption: Image 1: INSULATED ASSY, FILTER DOOR (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13, M14, M15, M16) 0270L00080 11 INSULATED ASSY, FILTER DOOR (M17, M18, M19, M20, M21, M22) 0270L00139 11 INSULATED ASSY, ECONOMIZER DOOR 0270L00081 21 POST-SIDE SUPPORT (M 1, M2, M3, [...]
-
Page 8
Partition A ssy 8 RP-526 A www. goodm anm fg.com www. am a na -ha c .c om[...]
-
Page 9
Partition Assy Ref. No: Part No: Description: Ref. No: Part No: Descri ption: Image 1: TUBING ASSY, COND COI L (M2, M4) 0201L00038S 11 TUBING ASSY, COND COIL (M12, M14, M16) 0201L00039S 11 TUBING ASSY, COND COIL (M6, M8, M10) 0201L00040S 11 TUBING ASSY, COND COIL (M11, M13, M15) 0201L00043S 11 TUBING ASSY, COND COIL (M5, M7, M9) 0201L00044S 11 TUBI[...]
-
Page 10
Belt Drive A ssy 10 RP-526 A www. goodm anm fg.com www. am a na -ha c .c om[...]
-
Page 11
Belt Drive Assy Ref. No: Part No: Description: Ref. No: Part No: Descri ption: Image 1: BELT DRIVE MOTOR (230/460)/60/3P (M17, M18, M19, M20) B3240007 11 BELT DRIVE MOTOR 1 HP (M1, M2, M3, M4, M5, M6, M7, M8, M11, M12, M13, M14) 0131L00003S 11 BELT DRIVE MOTOR 1.5 HP 575V (M9, M10, M15, M16, M21, M22) 0131L00004S 11 BLOWER SIDE ANGLE (QTY 3) 0121L0[...]
-
Page 12
Control Box A ssy 12 RP-526 A www. goodm anm fg.com www. am a na -ha c .c om[...]
-
Page 13
Control Box Assy Ref. No: Part No: Description: Ref. No: Part No: Descri ption: Image 1: DEFROST CONTROL BOARD PCBDM101S 11 TRANSFORMER 208/230, 24V (M1, M2, M5, M6, M11, M12, M17, M18) B1141643 21 TRANSFORMER 480V, 75VA, RESETTABLE (M3, M4, M7, M8, M13, M14, M19, M20) B1141672 21 TRANSFORMER 575/24V (M9, M10, M15, M16, M21, M22) 0130M00045S 21 24V[...]