Go to page of
Similar user manuals
-
Pressure Washer
Graco Inc. 1840
20 pages 1.6 mb -
Pressure Washer
Graco Inc. 824-001
24 pages 0.87 mb -
Pressure Washer
Graco Inc. 308-532
25 pages 0.69 mb -
Pressure Washer
Graco Inc. 801-643
12 pages 0.86 mb -
Pressure Washer
Graco Inc. 2800
24 pages 0.87 mb -
Pressure Washer
Graco Inc. 800-671
24 pages 0.65 mb -
Pressure Washer
Graco Inc. 802-777
16 pages 1.29 mb -
Pressure Washer
Graco Inc. 308-507
16 pages 0.42 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco Inc. 800-905, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco Inc. 800-905 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco Inc. 800-905. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco Inc. 800-905 should contain:
- informations concerning technical data of Graco Inc. 800-905
- name of the manufacturer and a year of construction of the Graco Inc. 800-905 item
- rules of operation, control and maintenance of the Graco Inc. 800-905 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco Inc. 800-905 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco Inc. 800-905, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco Inc. service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco Inc. 800-905.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco Inc. 800-905 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTRUCTIONS-PARTS LIST This rnanulll mntains IMPORTANT WARNINGS and INSTRUCTIONS READ AND RETAIN FOR REFERENCE HYDRA-CLEAN 8 71 0,720, I 01 0,1020 ~~ Pressure Washer Model 800-902, Series A 230/460 Volt, 3 Phase, 10 GPM Model 800-904, Series A 230/460 Volt, 3 Phase, 20 GPM 700psi.(48 bar) OPERATING PRESSURE . 1100 psi (75 bar) MAXIMUM WORKING PRES[...]
-
Page 2
HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD General Safety mis pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid through your skin and in[...]
-
Page 3
GROUNDING INSTRUCTIONS mis Droduct must be grounded. If it should malfunction 1- DANGER or bieak down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This equipment is equipped with a cord grounding plug. The plug must be plugged into an having an equipment-grounding conductor and a aooromia[...]
-
Page 4
HOSE SAFETY High pressure fluid in the hoses can be very dangerous. If the hose develops a leak, split or rupture due to any kind of wear, damage or misuse, the high pressure spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage. ALL FLUID HOSES MUST HAVE STRAlN RELIEFS ON BOTH ENDS. The strain r[...]
-
Page 5
INSTALLATION PUMP OIL Check for Shipping Damage Check the unit for any damage that may have occurred in shipping. Notify the carrler Immediately If there Is any damage. Set UP. Before connectingthe unit, be sure the electrical sewice matches the specification in Technical Data (inside back cover) and the voltage label on the unit. With the unit off[...]
-
Page 6
STARTUP washer to help insure that the unit is ready to operate Use this procedure whenever starting the pressure and starting is done safely. 1. Check the oil level. Pump: Add SA€ 20 or 30 weight non-detergent oil as necessary. 2. lhm on the water supply. CAUTION Never run the unit dry. Costly damage to the pump will result. Always be sure the w[...]
-
Page 7
Trigger Safety Latch WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, ALWAYS engage the trigger safely latch whenever spraying stops, even for a moment. in the engaged position, the trigger safety latch prevents the gun from being triggered accidentally by hand or if it is dropped[...]
-
Page 8
~ ~~~~~ - ~~ .~ SHUTDOWN, FLUSHING AND STORAGE WARNING PRESSURE RELIEF PROCEDURE To reduce the risk of serious bodily injury, including fluid injection and splashing in the eyes, or on the skin, always follow this than 10 minutes, when shutting down, and procedure whenever you stop sprayingformore before checking or repairing any part of the system[...]
-
Page 9
TROUBLESHOOTING CHART WARNING To reduce the risk of serious bodily injury, Including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warning before proceeding. I pump NnS rough Inlet filter clogged. I Low pressure andlor Wom or wrong size tip. Worn packings, abrasives i[...]
-
Page 10
PUMP SERVICE Servicing the Plungers To reduce the risk of serious bodily injury, NOTE Plunger repair kit, P/N 803-677 is available to including fluid injection, splashing in the eyes or replace retainers, O-rings. washers and follow the Pressure Relief Procedure Warnlng on the skin, or injury from moving parts, always backup rings for three cylinde[...]
-
Page 11
Servicing the V-Psckings NOTE: mere are two types of packing kits: one is packings only, the other includes the packings, rings and retainers. 1. Remove the manifold as outlined in the Pumping Section. 2. Carefully pull the packing retainer from the cut or damaged. manifold. Examine the O-ring and replace it if it is 3. Remove the v-packing and hea[...]
-
Page 12
PARTS DRAWING 800-903 Hydra-Clean@ I010 Pressure Washer 800-902 Hydra-Clean@ 710 Pressure Washer For wiring diagrams, see pages 13 and 15 9’ 7 12 308-533[...]
-
Page 13
PARTS LIST 800-903 Hydra-Clean@ 1010 Pressure Washer 800-902 Hydra-Clean@ 710 Pressure Washer REF NO. 2 1 3 4 5 6 7 8 10 9 11 12 13 14 15 16 17 18 19 PART 803-566 NO. 801 -940 100-21 4 100-527 800-447 177-144 800-444 802-845 803-m 801 -020 172-981 176-250 803-560 801 -376 803-576 803-769 801-91 1 803-575 803-574 803-770 803-088 803-517 100-21 4 100[...]
-
Page 14
PARTS DRAWING 800-905 Hydra-Clean@ 1020 Pressure Washer 800-904 Hydra-Clean@ 720 Pressure Washer For wiring diagrams, see pages 13 and 15 I 40 I I I I 14 308-533[...]
-
Page 15
PARTS LIST 800-904 Hydra-Cleans 720 Pressure Washer 800-905 Hydra-Clean@ 1020 Pressure Washer REF NO. 2 1 4 3 5 6 7 8 10 9 11 12 13 14 15 16 17 18 19 NO. PART 803-566 801 -940 100-21 4 100-527 800-447 177-144 8w-444 802-845 803-777 801 -020 172-981 803-560 176-250 603-767 801 -623 803-878 803-879 803-575 803-574 603-880 803-776 803-517 100-133 802-[...]
-
Page 16
PARTS DRAWING 803-577 Pump Assembly, 10 GPM 16 308-533[...]
-
Page 17
REF NO. 2 1 8 9 11 10 12 13 14 15 16 17 19 18 20 22 21 24 23 25 26 28 27 29 30 PART NO. REF 803-657 SCREW, Cap, socket hd. DESCRIPTION QTY NO. 8 803-639 WASHER, Lock 16 31 KIT 62 VALVE ASSEMBLY 33 6 803-630 O-RING 34 6 35 803-61 6 COVER, Valve 803-655 SCREW, Cap, socket hd. 2 8 36 37 KTT 37 SEAL, Oil 803-606 CRANKCASE 3 38 1 801-475 DIPSTICK 1 39 4[...]
-
Page 18
PARTS DRAWING 803-578 Pump Assembly, 20 GPM /- /- /- 22 27 18 308-533[...]
-
Page 19
PARTS LIST 803-578 Pump Assembly, 20 GPM REF NO. 2 1 8 9 10 11 12 13 14 16 15 17 19 18 21 20 22 23 24 25 26 28 27 29 PART NO. DESCRIPTION 803-659 SCREW, Cap, socket hd. 803-640 WASHER, Lock KIT43 ' VALVE ASSEMBLY 803-631 O-RING 803-650 CAI? Valve 803-624 COVER, Crankcase KIT 44 SEAL, Oil 803-617 CRANKCASE 803-648 DIPSTICK 803-627 GASKET, Cover[...]
-
Page 20
ACCESSORIES (Must be purchased separately) DOWNSTREAM CHEMICAL INJECTOR KIT BACKFLOW PREVENTOR 801-133 800-117 BRASS UP TO 5.5 GPM (21 LPM) 800-425 BRASS 5.6 TO 10.8 GPM (21 TO 41 Prevent back-up of contaminated water into fresh supply. Install upstream of pump. INLET PRESSURE REGULATOR 800-258 coupler for hose connection and adjustable nozzle. Inc[...]