Graco 215625 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 215625, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 215625 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 215625. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 215625 should contain:
- informations concerning technical data of Graco 215625
- name of the manufacturer and a year of construction of the Graco 215625 item
- rules of operation, control and maintenance of the Graco 215625 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 215625 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 215625, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 215625.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 215625 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instructions GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1980, Graco Inc. is registered to I.S. EN ISO 9001 PLURAL COMPONENT Mixer Manifold 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure Model 215625 Series C Low V olume Mixer: 1/4 npt fluid outlet; for use in low volume applications, such as air spray urethanes. Model [...]

  • Page 2

    2 307400 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 8 . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    3 307400 W ARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . D Fluid injected into the skin is a serious injury . The injury may look like just a cut[...]

  • Page 4

    4 307400 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Follow the grounding instructions on page 5. D If there is any static sparking or you feel an electric s[...]

  • Page 5

    5 307400 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment: 1. Pump: use a ground wire and clamp as instru[...]

  • Page 6

    6 307400 Operation Start-up The mixer manifold was tested in oil, which was left in to protect the manifold. Before operating, thoroughly flush the manifold to prevent contamination of the fluids. Flushing Procedure CAUTION Be sure to label all fluid path parts “component A” or “component B” when disassembling them. Doing so prevents interc[...]

  • Page 7

    7 307400 Operation Be sure all fluid is thoroughly flushed from the hose after each use. Disassemble all other dispensing equipment, as nec- essary , and clean thoroughly . CAUTION T o prevent fluid from setting up in the dispensing equipment, flush the system frequently . Be sure there is adequate solvent in the solvent supply before starting to s[...]

  • Page 8

    8 307400 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury . T o reduce the risk of an injury from injection, splashing fluid, or moving parts, f[...]

  • Page 9

    9 307400 Service Manifold Repair (See Page 10. ) W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Note: Repair kits are available for the manifold. Parts included in the kits are indicated with a †, for example (9†) See page 1 1. 1. Relieve the[...]

  • Page 10

    10 307400 Parts 11 Ref No.13 Ball V alve 215622, Series B Low V olume Ref No.24 Ball V alve 215623, Series B High V olume 18* 22 15* 27 29 31 30 28 34‡ 33‡ 32‡ 33‡ 23 26 T orque twice to 60–70 in-lb. (6.7–7.9 N S m) 05769 05768 14 20 *17 21 *17 *16 19* 22 15* 19* 25 28 26 30 4† 3† 12 2 1 8 9† 6† 7 6† 9† 8 5 13 or 24 13 or 24[...]

  • Page 11

    11 307400 Parts Models 215625 and 215626, Series C Ref No. Part No. Description Qty . 1 100721 PLUG, internal hex; 1/4; 1/4 npt 2 2 104472 CAPSCREW, hex hd; 10–32 x 1–1/2 12 3† 105694 SEAL, shaft; SST and PTFE R 2 4† 177019 RING, back-up; Delrin R 2 5 177021 NIPPLE, pipe, hex; 1/4 npt 1 6† 177022 SEA T , valve; Delrin R 2 7 HOUSING, manif[...]

  • Page 12

    12 307400 Parts Model 241692 Series A 5765B 2 3 4 5 6 9 7 8 Ref No. Part No. Description Qty . 1 215626 MANIFOLD, mixer; see full parts and listing on pages 10 and 1 1 1 2 157676 UNION, swivel, 90 _ 1 3 155699 ELBOW, street 2 4 161037 FITTING, union, adapter 2 Ref No. Part No. Description Qty . 5 156823 UNION, swivel 2 6 108233 V AL VE, needle 2 7 [...]

  • Page 13

    13 307400 T echnical Data Maximum working pressure 3000 psi (21.0 MPa, 210 bar) . . . . . . . . . . . . . . . . . . . . . Fluid port size Model 215625 1/4 npt(m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 241692 1/2 npt(f) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 14

    14 307400 Dimensions Model 215625 Model 215626 Model 241692 A Overall Length 5.0 in (127 mm) 5.5 in (140 mm) 5.5 in (140 mm) B Overall Height 5.375 in. (136 mm) 6.25 in (159 mm) 19.85 in (504 mm) C Overall Width 1.375 in (35 mm) 1.25 in (32 mm) 1.25 in (32 mm) D Fluid Inlets 1/4 npt(m) 3/8 npt(m) 3/8 npt(m) E Solvent Inlet 1/4 npt(m) 1/4 npt(m) 1/4[...]

  • Page 15

    15 307400 Notes head.notes[...]

  • Page 16

    16 307400 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for[...]