Go to page of
Similar user manuals
-
Pet Fence
Graco 288629
4 pages 0.42 mb -
Pet Fence
Graco Series C
6 pages 0.36 mb -
Pet Fence
Graco 255963
32 pages 3.43 mb -
Pet Fence
Graco 240-352
18 pages 0.71 mb -
Pet Fence
Graco 245924
4 pages 0.42 mb -
Pet Fence
Graco 240-361
18 pages 0.71 mb -
Pet Fence
Graco 215963
12 pages 0.15 mb -
Pet Fence
Graco 240-362
18 pages 0.71 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco 240-351, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 240-351 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco 240-351. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco 240-351 should contain:
- informations concerning technical data of Graco 240-351
- name of the manufacturer and a year of construction of the Graco 240-351 item
- rules of operation, control and maintenance of the Graco 240-351 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 240-351 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 240-351, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 240-351.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 240-351 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
308–845 Re v . C First choice when quality counts. t 8119A This gun and hose for Delta Spray Air Spray package or Delta Spray HVLP package This gun and hose for PRO 3500sc Electrostatic package INSTRUCTIONS–P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. ACET AL HUSKY t 307, W ALL-M[...]
-
Page 2
1A 308845 Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. Improve pressure control instructions (Graco Ref. 6557). Change 30psi HVLP fluid regulator and gauge to a 60psi gauge and regulator. Obsolete suction tube (Graco Ref. 6557).[...]
-
Page 3
1B 308845 Notes[...]
-
Page 4
308-845 2 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts List an[...]
-
Page 5
308-845 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . D This equipment is for professional use only . D Read all the instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intende[...]
-
Page 6
308-845 4 Setup CAUTION This equipment is compatible with most water-based materials. See the wetted parts in the T echnical Data section and your fluid and solvent manufacturer ’ s compatibility information. Do not use acid catalyzed materials; they are incom - patible with the acetal used in this pump. T OXIC FLUID HAZARD Hazardous fluid or tox[...]
-
Page 7
308-845 5 Setup Assembling the W all-Mount Unit See Fig. 1 Install the wall bracket (G) 5 ft (1.5 m) above the floor . For proper hole dimensions, use the W all Mounting Hole Layout on page 15. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation. Screw the bu[...]
-
Page 8
308-845 6 Operation Using the Gun See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer . Pressure Relief Procedure See Fig. 1 The system remains pressurized until pressure is manually relieved. T o reduce the risk of serious injury from pressurized fl[...]
-
Page 9
308-845 7 Operation Priming the System See Fig. 1 1. Close the gun air regulator (F). 2. If your system has a fluid pressure regulator (G), close it. 3. Open the bleed-type master air valve (K). 4. Slowly set the pump air regulator (E) pressure to 20 to 30 psi (140 to 210 kPa, 1.4 to 2.1 bar). The pump cycles quickly , then it slows down when it is[...]
-
Page 10
308-845 8 Operation When to Shut Down the System Shut down the system at the end of the work shift and before checking, adjusting, cleaning, or repairing the system. Always relieve the pressure . W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6. Flu[...]
-
Page 11
308-845 9 Maintenance See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections. Dependi[...]
-
Page 12
308-845 10 Parts List W all-Mount Packages with Fluid Pressure Regulators Model No. 240–349 , Delta Spray air spray package Model No. 240–350 , Delta Spray HVLP package Model No. 240–351 , no hoses (31) or gun (30) Model No. 240–352 , PRO 3500sc electrostatic package Model No. 240–353 , PRO 4500sc electrostatic package Ref. No. Part No. D[...]
-
Page 13
308-845 11 Parts Drawing 13 20 Grounding Detail 19 26 37 8088A 1 8 2 3 5 6 24 24 9 9 10 16 16 17 21 25 29 34 30 31 31 32 33 38 39 40 50 28 7 30 222–300 shown 12 27 27 15 15 W all-Mount Packages with Fluid Pressure Regulators Model No. 240–349 , Delta Spray air spray package Model No. 240–350 , Delta Spray HVLP package Model No. 240–351 , no[...]
-
Page 14
308-845 12 Parts List W all-Mount Packages with Surge T anks Model No. 240–361 , Delta Spray air spray package Model No. 240–362 , Delta Spray HVLP package Model No. 240–363 , no hoses (31) or gun (30) Ref. No. Part No. Description Qty . 1 240–210 SHIELD ASSY , front Contains 1a to 1h, shown in Fig. 2 on page 9 1 3 106–285 BOL T , “U”[...]
-
Page 15
308-845 13 Parts Drawing Grounding Detail 26 37 8089A 20 19 13 1 8 5 6 24 24 9 9 10 16 17 21 25 29 34 30 32 33 40 50 12 27 27 15 15 38 16 3 7 40 W all-Mount Packages with Surge T anks Model No. 240–361 , Delta Spray air spray package Model No. 240–362 , Delta Spray HVLP package Model No. 240–363 , no hoses (31) or gun (30) 31 11[...]
-
Page 16
308-845 14 Accessory Fluid Filter Kit Fluid Filter Kit 240–440 Ref. No. Part No. Description Qty . 101 1 14–361 FIL TER, fluid 1 102 1 13–322 CONNECT OR, male 1 103 054–188 TUBE; PTFE; R 3/8” O.D. 8 in. 104 1 13–534 ELBOW , male x female 2 105 1 1 1–917 NIPPLE; Nylon 1 The Fluid Filter Kit, listed above, can be installed to filter flu[...]
-
Page 17
308-845 15 T echnical Data Category Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar) Maximum operating temperature 120 _ F (49 _ C) Gun See separate gun instruction manual. Pump See separate pump instruction manual. Fluid pressure regulator See separate fluid pressure regulator inst[...]
-
Page 18
308845 16 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for [...]