Graco 307212ZAC manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco 307212ZAC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 307212ZAC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 307212ZAC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 307212ZAC should contain:
- informations concerning technical data of Graco 307212ZAC
- name of the manufacturer and a year of construction of the Graco 307212ZAC item
- rules of operation, control and maintenance of the Graco 307212ZAC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 307212ZAC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 307212ZAC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 307212ZAC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 307212ZAC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ST AINLESS STEEL, W A TERBASE COMP A TIBLE Fluid Pressure Regulators Used to regulate fluid pressure in low pressure systems only . Fluid Flow up to 3 GPM (1 1 liters/min) Instructions–Parts List 307212ZAC EN Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 2 for T able of Contents[...]

  • Page 2

    2 307212 T able of Contents Models 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    3 307212 Models Spring Operated Fluid Regulators Part No. Series Maximum Fluid Inlet Pressure, psi (kPa, bar) Regulated Pressure Range, psi (kPa, bar) Gauge Gauge Pressure Range, psi (kPa, bar) 214895 H 250 (1800, 18) 5–100 (34–700, 0.3–7) No n/a 214706  H 250 (1800, 18) 5–100 (34–700, 0.3–7) Y es (see 0–100 (0–700, 0–7) below)[...]

  • Page 4

    4 307212 Notes[...]

  • Page 5

    5 307212 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .  Do not stop or deflect fluid leaks with your hand, body , glove, or rag.  Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve the press[...]

  • Page 6

    6 307212 Installation FLUID SUPPL Y INLET BALL V A L VE OUTLET BALL V A L VE PIPE NIPPLES BACK PRESSURE VA LV E FLUID RETURN AIR FIL T ER & REGULA TOR Spring Operated Installation Models 214895, 214706, 217314, 221 1 18, 255374, and 24A082 Pilot Regulator Air Supply Line Air Operated Installation Model 214980 shown OUTLET BALL V A L VE AIR SUPP[...]

  • Page 7

    7 307212 Installation Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads. Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun or atomizing head. Before In[...]

  • Page 8

    8 307212 Operation CAUTION  The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator .  Always use the lowest possible air and fluid pressures for your application. High pressures cause premature spray nozzle and pump wear . NOTE: Reference numbers an[...]

  • Page 9

    9 307212 Operation 7. Adjust the fluid regulator to the desired setting. a. Spring Operated Regulators Only (see Fig. 3). The regulator can be adjusted in two ways:  Using the male end (B) of the regulator key (24), turn the socket–head adjustment screw (19) fully clockwise . V erify that the pressure setting has not changed.  Using the fem[...]

  • Page 10

    10 307212 Notes[...]

  • Page 11

    11 307212 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to Relieve the Pressure . Check all possible remedies in the T roubleshooting Chart before disassembling the fluid regulato[...]

  • Page 12

    12 307212 Service Service of the Air Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s air inlet. Refer to Fig. 2. 3. Release all the air and fluid pressure in [...]

  • Page 13

    13 307212 Service Models 214980 (shown) & 244375 29 10 13 23 7 1 17 22 26 18 9 15 16 4 20 40 6 21 3 NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N  m), then retorque to 125 in-lb (14 N  m) three times, consecu- tively , to compensate for diaphragm relaxation. 5 2 4 6 1 3 BOTTOM VIEW Air Bleed Hole[...]

  • Page 14

    14 307212 Service Service of the Spring Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s fluid inlet. See Fig. 1. 3. Release all fluid pressure in the regulato[...]

  • Page 15

    15 307212 Service 10 Models 217314 and 221 1 18 Models 214895, 214706, 255374, and 24A082 21 12 13 22 25 17 26 3 15 16 23 40 6 9 18 4 20 1 7 10 21 12 13 22 17 26 3 15 16 23 40 6 9 18 4 20 1 5 2 4 6 1 3 BOTTOM VIEW PET NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N  m), then retorque to 125 in-lb (14 N ?[...]

  • Page 16

    16 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 28 23 4*   *15  *16  *20 40*  1 6 18 26*  22*  17 13 Model 214895, Series H Without gauge. Includes items 1–26, 40 Model 214706, Series H With gauge. Includes items 1–40 Model 214706 only Ref No. Part No. Descri ption Qty . Ref. No. Part No. Descri ption Qty . 1[...]

  • Page 17

    17 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 23 4*   *15  *16  *20 40*  1 6 18 26*  22*  17 13 TI0037 Model 255374, Series A Model 24A082, Series A ISO pitch thread inlet and outlet (n ot compatible with US standard pitch – fluid housing coated with PTFE based polymer) Includes items 1–40 Ref No. Part No. [...]

  • Page 18

    18 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 28 23 4*   *15  *16  *20 40*  1 6 32 18 26*  25*  17 13 Model 221 1 18 only Model 217314, Series F With gauge. Includes items 1–32, 40 Model 221 1 18, Series E Without gauge. Includes items 1–26, 32–40 22*  39 Model 217314 only Ref No. Part No. Descri ption[...]

  • Page 19

    19 307212 Parts Model 214980 Series F Includes items 1–40  *9 7 29 10  *21  *3 27 28  *15  *16  *20 40*  4*  23 1 18 26*  22*  17 13 6 Ref No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 100644 SCREW , soc hd cap; 0.25”–20 x 0.75” 6 3 1 1 1736*  SPRING, compression 1 4 104319*  O-RING[...]

  • Page 20

    20 307212 Parts TI1697A Model 244375 Series B Includes items 1–41  *9 7 10  *21  *3  *15  *16  *20 40*  4*  23 1 18 26*   *22 13 6 29 17 19 41 Ref No. Part No. Description Qty . Ref. No. Part No. Descri ption Qty . 1 100644 SCREW , soc hd cap; 0.25”–20 x 0.75” 4 3 1 1 1736*  SPRING, compression 1 4 104319* ?[...]

  • Page 21

    21 307212 Dimensions Model 244375: 3” (76.2 mm) All Other Models: 4.94” (125.5 mm) 1.76” (44.7 mm) 1.8” (46 mm) 3/8 npsm female INLET 3.65” (93 mm) DIA. 3/8 npt(f) OUTLET 1/4 npt GAUGE PORT 10.25” (260 mm) 1/4 npt AIR INLET (Model 214980 only) 3/8 npsm female ADAPTER OUTLET (Models 217314 and 221 1 18 only)[...]

  • Page 22

    22 307212 T echnical Data Category Data Maximum Fluid Inlet Pressure 250 psi (1.8 MPa, 18 bar) Regulated Fluid Pressure Range Models 217314 & 221 1 18: 20–160 psi (0.15–1.1 MPa, 1.5–1 1 bar) Models 214706, 214895, 244375, 255374, & 24A082: 5–100 psi (30–700 kPa, 0.3–7.0 bar) Model 214980: 0–30 psi (0–210 kPa, 0–2 bar) Maxi[...]

  • Page 23

    23 307212 Performance Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 0123 45 FLUID FLOW kPa bar p si gpm liters/min 0 10 20 30 40 50 60 70 80 90 100 0123 45 3.82 7.62 1 1.42 15.22 22.10 liters/min 3.82 7.62 1 1.42 15.22 22.10 gpm FLUID FLOW MODELS 217314 and 221 1 18 MODELS 214706, 214895, 214980, 244375, 255374, and 24A082 kPa bar [...]

  • Page 24

    24 307212 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th[...]