Go to page of
Similar user manuals
-
Marine Instruments
Graco 236770
8 pages 0.13 mb -
Marine Instruments
Graco 234417
8 pages 0.81 mb -
Marine Instruments
Graco 234416
8 pages 0.81 mb -
Marine Instruments
Graco SDP15
44 pages 2.7 mb -
Marine Instruments
Graco 237503
8 pages 0.13 mb -
Marine Instruments
Graco 234415
8 pages 0.81 mb -
Marine Instruments
Graco 595
18 pages 0.75 mb -
Marine Instruments
Graco SDM5
44 pages 2.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco g250, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco g250 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco g250. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco g250 should contain:
- informations concerning technical data of Graco g250
- name of the manufacturer and a year of construction of the Graco g250 item
- rules of operation, control and maintenance of the Graco g250 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco g250 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco g250, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco g250.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco g250 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
308778L Instr uctions-P ar ts V olumetric Fluid Flo w Meter For precise metering of plural component fl uids and solvents. See page 2 f or model inf ormation, including maximum working pressure . Important Safety Instructions Read all warnings and instructions in this manual. Sav e th ese instr uctions. TI11579a Intrinsi call y Safe for Ha zardous [...]
-
Page 2
Models 2 308778L Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Low Pressure Meter s . . . . . . . . . . . . . . . . . . . . . 2 High Pressure Meters . . . . . . . . . . . . . . . . . . . . . 2 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . [...]
-
Page 3
Warnings 308778L 3 Wa r n i n g s The f ollowing warnings are f or the setup , use, grounding, mainten a nce, and repair of this equipment. The e xclama- tion point symbol ale r ts you to a ge neral warning and the hazard symbol ref ers to procedu re-specific risk. Ref er back to these wa r nings. Additional, product- specific w ar nings ma y be fo[...]
-
Page 4
Warnings 4 308778L EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not oper ate the unit when f atigued or under t he influence of drugs or alcohol. • Do not exceed the maximum w orkin g pressure or temperature rating of the lowest rated system component. See T echnical Data in all equipment man uals. • Use fluids and[...]
-
Page 5
Installation 308778L 5 Installation Dust and Foreign Matter A void h aving dust or foreign matt er enter the flow mete r by taking the f ollowing precautions: • Thoroughly flush the flui d supply lines bef ore install- ing the flo w meter . • When installing fittings, mak e s ure that no sealing tape overlaps into th e inside of t he pipe. • [...]
-
Page 6
Installation 6 308778L Gr ounding 1. Ground the fl ow met er b y connectin g a grounded cabl e to the sensor . Hav e a qualified electrician check the electrical groundin g continuity betw een the flow meter sensor and a true ear th ground; r emove t he cabl e connec- tor from the senso r and measure th e resistance from the cable connecto r Pin B [...]
-
Page 7
Operation 308778L 7 Operation Pressure Relief Pr ocedure 1. Shut off the fluid supp ly to the meter . 2. Shut off all electrical powe r to the fluid system. 3. F ollow the Pressure Relief Procedur e f or your fluid system d ispensing de vice . Flow Meter Function This is a positiv e displacement, gear flow meter . The gear flow meter is highly accu[...]
-
Page 8
Troubleshooting 8 308778L T r oubleshooting Bef ore ser vicing this equipment alw ays mak e sure to relie ve the pressure . NO TICE The sensor is not a serviceable part. Replace it if it is malfunctioning. Prob lem Cause Solution No flow volume displa yed at m onitor- ing unit. Flow v olume is too low to measur e. Increase flo w volume. Fluid is no[...]
-
Page 9
Maintenance 308778L 9 Maintenance Residue Build-up on the Meter Gear s Residue b uild-up may cause the meter gears to bind or stop rotating , which decreases the meter accur acy and mak es meter recalibra tion necessary . As more build-up occurs, recalibration is re quired more often. The frequency tha t your meter requires clean ing depends on the[...]
-
Page 10
Maintenance 10 308778L Cleaning or Servicing the Meter Chamber 1. Follo w the Pressure Re lief Procedure , on page 7. Then close the fluid shut-off valv e on each side of the meter . 2. Disconnect the cab le from the electronic sensor de vice. 3. Disconnect both flui d line fittings and remo ve the meter from t he fluid line. 4. Loosen the tw o scr[...]
-
Page 11
Parts 308778L 11 Pa r t s Flow Meter Kits, f or ProMix 2KS W all Fluid P anel 15V804 G3000 Meter Kit 15V827 G3000HR Meter Kit Ref. No. P ar t No. Description Qty 101 289813 METER, gear , G3000; used on 15V804; see p age 12 1 289814 METER, gear , G3000HR; used on 15V827; see page 12 1 104 501867 V AL VE, check 1 105 234628 HARNESS, cab le, wit h con[...]
-
Page 12
Parts 12 308778L Bare Meter Assemblies 289813 G3000 Meter , with 90° sensor connector 289814 G3000HR Meter , wi th 90° sensor connector * Not a replacement part. Order item 3, gear meter assembly . 1 T orque to 27-57 in-lb (3.1-6.4 N •m). T orque to 140-170 in-lb (15.8-19.2 N•m). 1 2 TI11580a 1 2 4 5 7 8 9 10 11 Item 3, Ge ar Meter Assembly i[...]
-
Page 13
Parts 308778L 13 239716 G3000 Meter 244292 G3000HR Meter * Not a replacement part. Order item 3, gear meter assembly . T orque to 27-5 7 in-lb (3.1-6.4 N•m). T orque to 140-170 in-lb (15.8-19.2 N•m). 1 2 TI7381a Item 3, Ge ar Meter Assemb ly includes items 4-11 2 2 4 5 7 8 9 10 11 1 1 Ref. No. P ar t No. Descr iption Qty . 1 114100 SCREW , sock[...]
-
Page 14
Parts 14 308778L 249426 G250 Meter 249427 G250HR Meter * Not a replacement pa r t. Order item 22, gear mete r assembly . 1 T orque to 27-5 7 in-lb (3.1-6.4 N•m). T orque to 140-170 in-lb (15.8-19.2 N•m). 1 2 TI11580a 1 2 4 5 7 8 6 11 Item 22, Gear Meter Assemb ly includes items 1-11 2 21 20 Ref. No. P ar t No. Descr iption Qty . 1 111308 SCREW [...]
-
Page 15
Dimensions 308778L 15 Dimensions G3000 and G3000HR Mounting Holes (bottom vie w) P ar t Nos. 289813 and 289814 P ar t Nos. 239716 and 244292 G250 and G250HR Mounting Hole s (bottom vie w) P ar t Nos. 249426 and 24942 7 1.73 in. (43.94 mm) M6 M6 1.73 in. (43.94 mm) 1/4-18 npt(f) inlet/outlet 1/4-18 n pt(f) inlet/outlet 1/4-18 npt(f) inlet/outlet 2.4[...]
-
Page 16
Technica l Data 16 308778L T e c hnical Data * F or most commonly used coatings, the flow meter reading will be accur ate to within +/- 0.5%. Accuracy will dimin- ish at low viscosities and low flow r ates. Maximum Fluid W orking Pressure G3000 an d G3000HR . . . . . . . . . . . . . . . . . . . . . . . G250 and G250HR . . . . . . . . . . . . . . . [...]
-
Page 17
Pressure Drop Curve 308778L 17 Pressure Dr op Cur ve G3000/G250 PSI 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 .8 0 .9 1.0 1.1 G3000HR/G250HR GAL/MIN GAL/MIN 0.0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 500 cps 400 cps 300 cps 200 cps 100 cps 50 cps 800 cps 3000 cps 2000 cps 1500 cps 1000 cps[...]
-
Page 18
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 308778 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 14[...]