Go to page of
Similar user manuals
-
Paint Sprayer
Graco X7
52 pages 3.44 mb -
Paint Sprayer
Graco 395/490/495/595
59 pages 8.1 mb -
Paint Sprayer
Graco 16N654
44 pages 11.86 mb -
Paint Sprayer
Graco GTX 313385B
18 pages 1.47 mb -
Paint Sprayer
Graco Monark 03289A
16 pages 0.71 mb -
Paint Sprayer
Graco 309294H
42 pages 1.29 mb -
Paint Sprayer
Graco 16H960
44 pages 11.86 mb -
Paint Sprayer
Graco 16H242
32 pages 6.8 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco GMax 233718, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco GMax 233718 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco GMax 233718. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco GMax 233718 should contain:
- informations concerning technical data of Graco GMax 233718
- name of the manufacturer and a year of construction of the Graco GMax 233718 item
- rules of operation, control and maintenance of the Graco GMax 233718 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco GMax 233718 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco GMax 233718, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco GMax 233718.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco GMax 233718 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
233705 309408 Rev . B OPERA TION – UTILIZAÇÃO – FONCTIONNEMENT – FUNCIONAMIENT O GMax Sprayers 3300 psi (228 bar , 22.8 MPa) Maximum Working Pressure Pressão máxima de trabalho de 3300 psi (228 bar , 22.8 MPa) Paression maximale de service 3300 lb/po 2 (228 bar , 22.8 MPa) Presión máxima de operación 3300 psi (228 bar , 22.8 MPa) G[...]
-
Page 2
309408 2 Danger d’incendie et d’explosion : les gaz de solvant et de peinture peuvent s’enf lammer ou explos er . Pour évi ter les ri sques d’incen die et d’ explosi on : N’ut iliser l’appareil que dans une zone extrêmem ent bien aérée. Élimi ner toute sourc e d’inflammati on ; tel le que veilleuses, cigarettes et arcs [...]
-
Page 3
3 309408 CONTROLS / CONTROLES / COMMANDES / CONTROLES Engine Controls Controles do motor Commandes de moteur Controles del motor 8695A On/Off Switch Aan/Uit Schakelaar Interrupteur Marche/Arrêt Ein-Aus-Schalter On/Off Switch Interruptor de ligar e desligar Interrupteur marche/arrêt Interruptor de encendido/apagado T rigger Lock Fecho do gatilho L[...]
-
Page 4
309408 4 1. Connect appropriate Graco high-pressure hose to sprayer . T ighten securely . 2. Connect other end of hose to gun. Setup 3. T ighten securely . 4. Remove tip guard. Note: Remove second gun port cap for multiple guns and repeat steps 1 – 4, 7, 8, 10[...]
-
Page 5
5 309408 5. Install clean inlet strainer . 6. Fill throat packing nut with TSL to prevent premature packing wear . Do this each time you spray and store. 7. Check engine oil level. Add SAE 10W–30 (summer) or 5W–20 (winter), if necessary . 8. Fill fuel tank. 9. Ground sprayer with grounding clamp. Approximate Fill Level (cold) Setup[...]
-
Page 6
309408 6 1. Place suction tube and drain tube in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. 2. T urn prime valve down. T urn pressure control to lowest pressure. Startup 3. Set pump switch OFF . P AINT FLUSH[...]
-
Page 7
7 309408 Startup a. Move fuel valve to open b. Move choke to closed c. Set throttle to fast d. Set engine switch ON e. Pull starter cord f. After engine starts, move choke to open g. Set throttle to desired setting – Digital display is functional after engine starts – 4. Start engine a. b. c. d. e. f. g.[...]
-
Page 8
309408 8 Note: Inspect fittings for leaks. Do not stop leaks with your hand or a rag! If leaks occur , turn sprayer OFF immediately . Do Pressure Relief in Cleanup, 1. – 3. on page 17. T ighten leaky fittings. Repeat Startup, 1. – 5 . If no leaks, continue to trigger gun until system is thoroughly flushed. Proceed to 6. Startup 5. Set pump swit[...]
-
Page 9
9 309408 9. Place siphon tube in paint pail. 10. T rigger gun again into flushing fluid pail until paint appears. Assemble tip and guard, page 9. SwitchTip and Guard Assembly 1. Engage trigger safety . 2. Insert SwitchT ip . Insert seat and OneSeal . 3. Screw assembly onto gun. Hand tighten. FLUSH P AINT SwitchT ip OneSeal seat Startup safe[...]
-
Page 10
309408 10 Digital T racking System (DTS) Close cover when spraying to protect from overspray Operation Main Menu 1. Do Startup steps 1. – 3. 2. Start engine, page 7. Sprayer Model momentarily displays, e. g., G5900 = GMax 5900 Note: Information other than pressure can not be accessed if system pressure is greater than 200 psi (14 bar , 1.4 MP[...]
-
Page 11
11 309408 Digital T racking System (DTS) 3. Short press DTS button to move to Job Gallons (or Liters x 10). 4. Press and hold to reset to zero, or short press DTS button to move to Lifetime Gallons (or Liters x 10). 5. Short press DTS button to move to Auto- Clean T imer operation (Manual 309278). Note: LIFE displays briefly , then the number of ga[...]
-
Page 12
309408 12 W atchDog Pump Protection System Pump stops automatically when material pail is empty . 1. Do Startup . 2. Press and hold DTS button, release when ON is displayed. Note: GAL (or LITER) flashes while pump protection system is active. EMPTY displays and the pump stops when pump protection system detects an empty material pail. 3. T urn [...]
-
Page 13
13 309408 Secondary Menu – Stored Data and W atchDog Pump Protection Modes 1. Do Startup steps 1. – 3. Pressure must be at zero. 2. Start engine, page 7. Pressure display appears. 3. Simultaneously press DTS button and set pump on/of f switch on. Resettable Hour Meter appears. Sprayer model momentarily displays, e.g., G5900 = GMAX 5900. P AINT [...]
-
Page 14
309408 14 Secondary Menu – Stored Data and W atchDog Pump Protection Modes 4. Press and hold to reset to zero, or 5. Short press DTS button to move to Lifetime Hour Meter . 6. Short press DTS button to move to TOT AL Gallons (all pressures). 7. Press DTS button to move to stored error code. Press and hold DTS button to clear error code to E=00. S[...]
-
Page 15
15 309408 9. Short press DTS button again to move to W atchDog MAN (manual) mode. 10. Press and hold to switch between MAN (stan- dard) and AUTO mode. In AUT O mode, W atchDog pump protection is active once pressure is over 1500 psi (103 Bar , 10.3 MPa) 1 1. Short press to return to step 3. 12. T urn pump switch OFF at any time to exit stored data [...]
-
Page 16
309408 16 heavy edges Spray T est Pattern Clearing Tip Clogs 1. T rigger gun and spray test pattern. Slowly adjust pressure to eliminate heavy edges. Use smaller tip size if pressure adjustment can not eliminate heavy edges. 2. Hold gun perpendicular , 10–12 in. (25–30 cm) from surface. Spray back and forth. Use strokes overlapped by 50%. Start[...]
-
Page 17
17 309408 Cleanup 1. Set pump switch OFF . T urn engine OFF . 2. T urn pressure to lowest setting. T rigger gun to relieve pressure. 3. T urn prime valve down. Perform AutoClean procedure (Manual 309278) or follow conventional flushing procedure that follows: 4. Remove guard and SwitchT ip. Pressure Relief Pressure Relief Pressure Relief P AINT[...]
-
Page 18
309408 18 5. Unscrew bowl, remove filter . As- semble without filter . Clean filter . 6. Clean filter , guard and SwitchT ip in flushing fluid. 7. Remove siphon tube set from paint and place in flushing fluid. Use water for water base paint and mineral spirits for oil base paint. FLUSH P AINT FLUSH[...]
-
Page 19
19 309408 8. T urn engine ON and start engine. Set pump switch ON. 9. T urn prime valve horizontal. 10. Hold gun against paint pail. T ake trigger safety OFF . T rigger gun until flushing fluid appears. T urn pressure control up until motor begins to drive pump. 1 1. Move gun to flushing pail, hold gun against pail, trigger gun to thoroughly flush [...]
-
Page 20
309408 20 Caution: If flushing with water , do not leave water in sprayer . Flush again with mineral spirits, oil or Pump Armor and leave this protective coating in the sprayer to help prevent freezing or corrosion and increase sprayer life. 13. Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. T urn pump s[...]
-
Page 21
21 309408 DTS Error Codes Service 309409 Reference Repair Manual 309409 or 30941 1 or call your distributor for service[...]
-
Page 22
309408 22 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception o f any special extended or limited warranty published by Gr[...]