Graco Model 260410 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Graco Model 260410, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco Model 260410 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco Model 260410. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco Model 260410 should contain:
- informations concerning technical data of Graco Model 260410
- name of the manufacturer and a year of construction of the Graco Model 260410 item
- rules of operation, control and maintenance of the Graco Model 260410 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco Model 260410 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco Model 260410, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco Model 260410.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco Model 260410 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is r egistered to I. S. EN ISO 9001 311628C Instr uctions - P ar ts List GTP10 Herbicide Pump For pumping herbicides. Do not use to pump other fluids including water . Model 260410, 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor) Model 260411, 10 gpm (38 lpm), 12 VDC (CS[...]

  • Page 2

    Warnings 2 311628C Wa r n i n g s The f ollo wing general w arnings are for th e setup , use , grounding, ma intenance, and repair of this equipment . Addi- tional, more specif ic warnings ma y be f ound throug hout the body of this man ual where applicab le . Symbols appear - ing in the body of the man ual ref er to these gener al warnings. When t[...]

  • Page 3

    Warnings 311628C 3 EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not oper ate the unit when f a tigued or under t he influence of drugs or alcohol. • Do not exceed the maximum workin g pressure or temperature rating of the lo west rated system component. See T echnica l Data in all equipment man uals. • Use fluids a[...]

  • Page 4

    Installation 4 311628C Installation When unpac king pump , chec k f or shipping damage. Repor t any shippin g damage to delivering carrier imme- diately . Mounting Pump 1. Apply herbicid e compatible sealant to large thre ad on bu ng adapter (9) ( 2 in. x 1-1/2 in. reducer fit ting). Install b ung adapter on tank. 2. Assemble suction tube sections [...]

  • Page 5

    Installation 311628C 5 7. Screw str ain relief (6b) into electr ical cov er (2a). 8. P osition powe r cabl e (6c) so the lar ge diameter of power cable e x tends throug h strain relief (6b). 9. Tighten nut o n strain relie f to form a seal arou nd the powe r c abl e. 10. Reinstall ele ctr ical cov er (2a) on the pump. 11. Remove 1/2 in. (13 mm) of [...]

  • Page 6

    Operation 6 311628C Operation On/Off switch le v er (8d) is loca ted under no zzle holder . Remov e n ozzle bef ore t urning pump on. 1. Mo v e s witch le v er (8d) on. 2. Inser t nozzle into tank and actuate no zzle le v er to dispense herb icide. 3. Immediately after dis pensing h erbicide t ur n switch le v er (8d) off . Maintenance 1. Clean inl[...]

  • Page 7

    Maintenance 311628C 7[...]

  • Page 8

    Troubleshooting 8 311628C T r oub leshooting Prob lem C ause Solution Motor runs but pump will not pr ime. Mo tor rotation wrong. (12 VDC units only .) Check wiring instr uctions for possible problems. Missing relief v alv e o-ring seal (4c). Remov e ge ar cov e r (1b) inspect sea l (4c), replace if missing or damaged. Sheared drive k e y (1g). Rem[...]

  • Page 9

    Troubleshooting 311628C 9 Herbicide leaking in m otor mount. F ault y or damaged motor shaft se al (1h). Replace shaft seal Operatin g pump e xtended t ime with nozzle closed. Do not e xceed 5 minute s of operat ion with nozzle closed. Motor shaft wor n. Replace motor if shaft has groov e worn in seal area. Motor ov erheating. Gears (1c/10a) bindin[...]

  • Page 10

    Parts Drawing 10 311628C Pa r t s D r a w i n g 3a 3c 3d 1a 8e 8b 8f 8g 1i 1f/10c 1g/10b 2e 2f 3b 1b 1c/ 10a 1d 4b 4a 2h 2i 8c 8a 8d 4c 9 1k 1h 2g 2c 2b 2d 5c 5a 2a 2c 6b 6c 6a Models 260410 and 260411, 12 VDC Models 260408 and 260409, 115 V A C 1j 260544 260454 260456 260458 260433 260300 5a 5b 253723 260450 253721 253718 260452 253719 4d 7[...]

  • Page 11

    Parts Li st 311628C 11 Pa r t s L i s t Models 260410 and 260411, 12 VDC Models 260408 and 260409, 115 V A C ▲ Replacement Danger and W ar ning labels, tags , and cards are av ailab le at no cost. * Use d on 12 VDC models only Ref. No. Description Qty . 1 260458 KIT , pump with s wivel, b lue (includes items 1a-1k) 253723 KIT , pump with s wivel,[...]

  • Page 12

    Technica l Data 12 311628C T echnical Data Va l o x ® is a register ed tra demark of the Gener al Electric Company P erf ormance Chart Working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 psi (0.07 MP a, 0.7 bar) Inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 in. npt Outlet siz[...]

  • Page 13

    Technical Data 311628C 13[...]

  • Page 14

    All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 311628 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX 14[...]