Go to page of
Similar user manuals
-
Paint Sprayer
Graco GMax 233709
26 pages 1 mb -
Paint Sprayer
Graco 309353B
4 pages 0.08 mb -
Paint Sprayer
Graco 230-998
16 pages 0.21 mb -
Paint Sprayer
Graco 243012
24 pages 0.63 mb -
Paint Sprayer
Graco 222300
40 pages 0.57 mb -
Paint Sprayer
Graco 390
12 pages 0.61 mb -
Paint Sprayer
Graco 295530
34 pages 1.89 mb -
Paint Sprayer
Graco 313483A
88 pages 13.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco XP70, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco XP70 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco XP70. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco XP70 should contain:
- informations concerning technical data of Graco XP70
- name of the manufacturer and a year of construction of the Graco XP70 item
- rules of operation, control and maintenance of the Graco XP70 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco XP70 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco XP70, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco XP70.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco XP70 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Instr uctions-P ar ts XP70 Plural-Component Spra y er Complete mechanical fix ed ra tio plural-component spray er used f or proportioning, mixing, and spraying tw o component qui c k setting materials. For pr ofessional use onl y . See page 11 f or maxim um working pressure and model inf orm ation. P atents P ending Impor tant Safety Instructions R[...]
-
Page 2
2 3A0420H Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Impor tant T wo-Compo nent Material Information . 7 Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . . 7 Mater ial Self-ignition . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
Related Manuals 3A0420H 3 Related Manuals Manuals ar e av ailab le at www .gr aco .com Component Manu als in English: Manual De scription 311762 Xtreme ® Displacement Pumps Instr uctions-Part s 311238 NXT ® Air Motor Instruc tions-P ar ts 3A0590 Mix Manif old Instr uctions-Part s 312747 20 Gallon Double W all Hopper Kit Instr uctions-Part s 30952[...]
-
Page 4
Warnings 4 3A0420H Wa r n i n g s The f ollowing w arnings are fo r the setup , use , grounding, mainten ance, and rep air of this equipment. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols r ef er to procedure-sp ecific risks. When these symbols appear in the body of this man ual, ref er ba c k to these W [...]
-
Page 5
Warnings 3A0420H 5 SKIN INJECTION HAZARD High-pressure fluid from gun , hose leaks, or ruptured components will pierce skin. This ma y look lik e just a cut, but it is a serious injur y that can resu lt in amputation. Get immedi ate surgical trea tment. • Do not spra y without tip guard and trigger guard inst alled. • Engage trigger loc k when [...]
-
Page 6
Warnings 6 3A0420H T O XIC FLUID OR FUMES HAZARD T oxic fl uids or fumes can cause serious injury or death if splashed in the ey es or on skin, inh aled, or s wal- lowe d. • Read MSDSs to kno w the specific hazards of the fluids y ou are using. • Store hazardous flu id in approv ed contain ers, and dispose of it according to applicab le guideli[...]
-
Page 7
Important Two-Component Materi al Information 3A0420H 7 Impor tant T w o-Component Material Inf ormation Isocy anate Conditions Material Self-ignition K eep Components A and B Separate Moisture Sensitivity of Isocy anates Isocy anates (ISO) are cat alysts used in two componen t f oam and polyurea coatings. ISO will react with moisture (such as humi[...]
-
Page 8
Important Two-Component Material Information 8 3A0420H Changing Materials • Changing materi al types us ed in your spra yer requires special atte ntion to a void eq uipment dam- age and do wntime. • Alwa ys clean the flui d inlet strainers after f lushing. • When changing betw een epo xies and uret hanes or polyureas , disassemble and clean a[...]
-
Page 9
Overview 3A0420H 9 Overview Usage The XP70 plural- component spr a ye r is a mechanical fix ed ratio spra y er that can mix and spray most two-com- ponent epo xy and ure thane protectiv e coatings . When using quic k-setting material (less than 10 minute pot lif e) a remote mix man if old must be used. The two pumps ar e carbide seat se v ere duty [...]
-
Page 10
Initial System Setup 10 3A0420H Initial System Setup Complete the f ollowing steps in the order t hey are listed , as the y apply to your specif ic system, for initial system setup . 1. Check the shipment f or accuracy . En sure you hav e receiv ed e v erything you order ed. See Component Identific ation , page 12. 2. Chec k f or loose fitting s an[...]
-
Page 11
Models 3A0420H 11 Models Car t-Mounted XP70 Spra yer s All XP70 spra y ers include st atic mix ers, 3/ 8 x 25 ft hose , clean up mix er , 1/4 x 10 ft ( x m) whip hose , and XTR 7 spr a y gun with a 519 tip . See Accessories and Kit s on page 52 for a list of all optional accessor ies. Bare Pr opor tioning Pump P ac ka ges All pump pac kages use a N[...]
-
Page 12
Component Identification 12 3A0420H Component Identification Key: A Air Motor Supply Hose B Main Air Controls; see page 13 C Air Inlet - 3/4 Npsm(F) D High Pressure Fluid Pump E Air Motor F Fluid Heater (optional) G Solvent Flush Pump (optional); see page 14 H Solvent Flush Pump Air Controls; see page 14 J 7 Gallon Hoppers (optional) KC a r t LB r [...]
-
Page 13
Component Identi fication 3A0420H 13 Fluid Contr ol Assembl y Main Air Contr ols F IG . 2 AC AA AF AE AD AB AM AK AL AJ AN Key: AA Fluid Manif old AB Mix Manif old AC Circulation Handle AD Solvent Flush V alve AE Dual Shutoff Handle AF Fluid Pressure Gauges AG Fluid Supply Inlet (Behind Fluid Manif old) AH Fluid Circulation Fitting s AJ B Comp onen[...]
-
Page 14
Component Identification 14 3A0420H 45:1 Solvent Flush Pump Kit 262393 (optional) Air Contr ols F IG . 4: Solvent Flush Pump Kit Key: BA Solvent flush pump (Merkur Pump) BB Fluid Inlet BD Muffler BE Prime/Flush/Sample valv e BF Fluid Outlet Hose BG Circulation hose BA BB (suction hose no t shown) BD BG BF r_571100_3a0420a_4 a-2 BE F IG . 5: Solvent[...]
-
Page 15
Component Identi fication 3A0420H 15 Air Line Bleed-type ma ster air v alve (CA): required in y our sys- tem to reliev e air trapped between it and the air motor when the v alve is closed. • Be sure the v alv e is easily accessible from the pu mp and located do wnstream from the air regulator . • Pump air regulator (CB): to control pump speed a[...]
-
Page 16
Setup 16 3A0420H Setup Location 1. Locate the pr opor tioner on a le v el surf ace . 2. P osition the propor tioner f or con v enient oper ator access and maintenance , saf e routing of air and fluid lines , and easy connection of componen ts and accessories. 3. F or permanent mounting, remo v e wheels and mount the fr ame to the floor . See Dimens[...]
-
Page 17
Setup 3A0420H 17 Wire Spra yer s with Explosion-Pr oof Heater s (Hazardous location spra y ers onl y) Improperly installed or c onnected equipm ent will create a hazardous cond ition and cause fire , e xplosion, or elec- tric shock. F ollow local regulations. When e xplosion-pr oof heaters are used, en sure the wir- ing, wiring connections, swit ch[...]
-
Page 18
Setup 18 3A0420H Air Motor P osition The air motor posit ion must be se t f or the mix ratio of the machine, which is defi ned by which two pumps are mounted. 1. V erify that the correct pumps are mounte d f or yo ur mix ratio by v olume. See char t in Bare Pr oportion- ing Pump P acka ges on page 11. 2. V erify that the motor position is adjuste d[...]
-
Page 19
Setup 3A0420H 19 Connect Air Suppl y 1. Connect the air sup ply hose to the 3/4 npt(f) air filter inlet (C). NO TE: Use a 3/4 in. ( 19.1 mm) ID minim um air hose. Air consumption is 75 cfm per gallon per min ute spra ying. Do not use pin fittin g type quick discon - nects. 2. Remo ve plugs as necessary for so lvent pump and f eed supply p ump air h[...]
-
Page 20
Pressure Relief Procedure 20 3A0420H Pressure Relief Pr ocedure Relieve A and B Fluid Pressure 1. Engage the tr igger lo ck. 2. Close the main air shutoff valve (CA). 3. Shut off he aters, if used. 4. Shut off feed pumps, if used. 5. Remove the spray tip and clean . 6. Disengage th e trigger lock. 7. Hold a metal part of the gun firmly to a grou nd[...]
-
Page 21
Prime Empty Sprayer 3A0420H 21 Prime Empty Spra y er Prime A and B Fluids NO TE: The equip ment is tested with mineral oil at the factory . If necessary , flush out the oil wit h a compatibl e solvent bef ore sprayi ng. See Empty and Flush Entire System (ne w spray er or end of job), page 27. Do not install the gun spra y tip yet. T o av oid splash[...]
-
Page 22
Prime Empty Sprayer 22 3A0420H Prime Solvent Flush Pump F ollow inst ructions if the optional solv ent flush pump kit is used. 1. Connect the flush pail ground wire to a metal pail of solvent. 2. Place the siphon tube an d the solv ent circulation hose (BG) in the pail of solvent. 3. Open the so lv ent prime valv e (BE) on th e solv ent pump (BA) o[...]
-
Page 23
Prime Empty Sprayer 3A0420H 23 Recir culate or Re-Prime After a Pump Runs Dry Without Heat If using a system that do es not require heat, recircula- tion is still required prior to spra ying. Recirculation ensures th at any settled fillers a re mixed in, the pump lines are fully primed, and the pump chec k v alv es are operat ing smoothly . Recircu[...]
-
Page 24
Spray 24 3A0420H Spra y NO TE: Afte r the first day of spraying foll ow Pressure Relief Proce dure, page 20, and tighten the thr oat pac king nuts on both pumps. 1. If heaters are used, t urn them on. T o adju st the heater tempe rature , ref er to the Viscon HP manua l f or instr uctions, and the Heat Fluid section, page 23. Circulate as necessar [...]
-
Page 25
B Side Mix Manifold Restriction 3A0420H 25 B Side Mix Manif old Restriction If the mix m anif old (AB) is mounted on the machine , yo u do not need to adjust the restr ictor (AJ) . Leav e open two tur ns minimum. The B side restrictor (AJ) in the mix manifold is only used when the mix ma nif old is positioned remote from the machine with a short mi[...]
-
Page 26
Flush Mixed Material 26 3A0420H Flush Mixed Material Flush the mix manif old wh en any of the f ollo wing situa- tions occur . • breaks i n spra yin g • ov er night shutdown • end of potlif e T o flush the entire syst em, see Empty and Flush Entire System (new sp ray er or end of job) , page 27. Flush Mix Manif old, Hose, and Spra y Gun If y [...]
-
Page 27
Empty and Flush Entire System (ne w sprayer or end of job) 3A0420H 27 Empty and Flush Entire System (ne w spra y er or end of job) NO TE: • If the syste m incl udes heater s and heated hose, turn them off and allo w to cool bef ore flushing. Do not turn on the heater s until the fluid lines are clear of solvent. • Cover flu id containers and us[...]
-
Page 28
Shutdown 28 3A0420H 6. Run the pumps until the A and B hoppers ( J) are empty . Salv age the material in sepa rate , clean con- tainers. 7. Close the main air shutoff valve (CA). 8. Wipe the hopper s (J) clean, then add solv ent to each. Mov e the cir culation lines (U) to w aste con- tainers and pu sh out the dirty fluids. 9. Mo ve the recirculat [...]
-
Page 29
System Verification 3A0420H 29 System V erification Graco recommend s running the follo wing tests daily . Check f or Normal Operation Ev er y time you star t spraying: • W atch th e fluid gauges (AF ). A pressure drop occurs dur ing pump stro ke changeov er . It should be quick and synchronous . • Stop the pumps on t he upstroke. Check that bo[...]
-
Page 30
Maintenance 30 3A0420H Maintenance Filter s Once a week chec k, clean, and replace (if needed) the f ollowing filters. • Both pump filters; see lower manual f or instructions. • Main air inlet manifold filter; see Replace Air Filter Element , page 34 . • Spra y gun handle filter; see spra y gun manu al. Seals Once a week, che ck and t ighten [...]
-
Page 31
Troubleshooting 3A0420H 31 T roub leshooting ✖ Fluid ratio will be wr ong. ◆ Purge all air fr om system bef ore pr oportioning fluids. Prob lem Cause Solution System stops or will not star t. Ai r pressure or volume too low . Increase; check air compressor . Closed or rest ricted air line or air val ve . Open or clean. Fluid v alv es closed. Op[...]
-
Page 32
Troubleshooting 32 3A0420H Pump T roub leshooting This char t uses proportioning fluid gauges to determin e pump malfunction s. Obse r v e the gauge readin gs during the strok e direction indicate d by the bold ar row , and immediately after clos ing the gun or mix manif old. Ref er to other manuals t o troub leshoot individual compo nents. Fluid o[...]
-
Page 33
Repair 3A0420H 33 Repair F ollow Shutdo wn , page 28, if se r vice time ma y e xceed pot lif e time , bef or e ser vicing fluid components , and bef ore tr anspor ting spra y er to a service area. Pump Assembl y The displacemen t pumps and air motor ma y be remov ed and ser viced separately or the entire pump and motor assemb ly can be remo ved wit[...]
-
Page 34
Repair 34 3A0420H Remove Air Motor 1. Cycle the y ok e and pump rods near the bottom of their stroke . F ollow Shutdown , page 28. 2. Disconnect the a ir line from the air motor (103). 3. Remo ve the air motor rod co v er (121) and pump guards (122). 4. Use a wrench to hold the tie rod (102) flat s to kee p the rods fr om tur ning. U nscrew the nut[...]
-
Page 35
Repair 3A0420H 35 F IG . 8: Air Co ntrol Assembl y 258983 201 215 214 213 216 211 202 203 204 209 208 207 205 206 210 214 209 206 r_571101_3A0420A_ 1a-2 Air Flow Air Flow 5, 8[...]
-
Page 36
Repair 36 3A0420H Mix Manif old Assembl y 1. F ollow Pressure Relief Pr ocedure , pa ge 20. 2. Disconnect the f luid hose (25) and the flush hose from the mix m anifold (36). 3. Loosen th e union fittings (306 ) that connect to the mix manif old adapte r fittings . 4. Remove the mix manifold assembly (36). 5. See mix manif old man ual f or ser vice[...]
-
Page 37
Repair 3A0420H 37 8. Place a h andle (311) on a v alv e stem (30 2) at the v er tical, or near v er tical, spra y position . 9. Apply blue threadlock on the nut (304) threads an d tighten the ha ndle against the spring (320) and clip (318). T orque to 70-80 in.- lbs. (7.9 -9 N•m). 10. Place the ro d (312) and the second handle (311) on second v a[...]
-
Page 38
Repair 38 3A0420H Hoppers 1. If material is in the hoppe r pump out the remainin g material. 2. If the pump has failed: a. Place a w aste container beneath th e plug on fit- ting (61). Remov e th e plug. b . Drain all material from hopper into the waste container . c. Install plug after material is no longer draining from fitting (61). 3. F ollow P[...]
-
Page 39
Repair 3A0420H 39 Optional Fluid Heater s NO TE: Wiring fo r heaters is not pro vided. See the Vis- con HP heater manual for wiring, repa ir , and par ts infor- mation f or e xplosion-proof heaters . Service and Repair 1. F ollow Pressure Relief Pr ocedure , pag e 20. 2. Disconnect t he fluid lines and electrical wiring from the fluid heater . 3. R[...]
-
Page 40
Parts 40 3A0420H Pa r t s Car t-Mounted XP70 Spra yer 1 15 14 13 16 11 3 17 18 9 8 7 5 10 12 17 64 50 53 38 54 13 13 11 52 1. Apply anaerobic pipe sealant to all non-s wiv eling pipe threads. 2 r_571101_3a0420a_30 a r_571101_3a0420a_30a[...]
-
Page 41
Parts 3A0420H 41 Car t-Mounted XP70 Spra yer Contin ued 23 22 4 18 5 6 24 55 56 58 59 60 61 62 24 24 22 41 37 35 36 32 27, 28 26 52 48 18 5 1 57 69 49 “A” 49 “B” 66 70 27, 28 32 27, 28 25 29 30 31 r_571101_3a0420a_44 a-1 r_571101_3a0420a_4 5a TI17434a 90 89 65 (inside hopper)[...]
-
Page 42
Parts 42 3A0420H Common P arts ▲ Replacement Danger an d W arning labels, tags , and cards are av ailab le at no cost. ✖ Not shown. Ref. P art Description Qty . 1 258913 CART 1 2 262476 AXLE, vertical 1 3 111841 WASHER, flat; 5/8 2 4 PACKAGE, pump; see page 44 1 5 100133 WASHER, lock; 3/8 7 6 100101 SCREW, cap, hex hd; 3/8 -16 x 1 4 7 113362 WH[...]
-
Page 43
Parts 3A0420H 43 P arts V arying b y Model with Hoppers P arts V arying b y Model with No Hoppers Ref. Par t Description XP70 Plural-Component Sp ray er Models 571102 571152 57120 2 571252 571302 571402 4 571100 PUMP , fixed ratio , 1:1 1 571150 PUMP , fixed ratio , 1.5:1 1 571200 PUMP , fixed ratio , 2:1 1 571250 PUMP , fixed ratio , 2.5:1 1 57130[...]
-
Page 44
Parts 44 3A0420H Bare Pr opor tioning Pump P ac ka ge 1 T orque together to 5 0-60 ft-lbs (68-81 N•m). T orque to 145-155 ft -lbs (196-210 N•m). Apply blue thread sealant. Inser t lanyard from loc king pin onto pumps (17, 18) as shown. Do not apply lubricant. T orque to 70-80 ft-lbs (9 5-108 N•m). Apply lithium grease to mating tapered surfac[...]
-
Page 45
Parts 3A0420H 45 Common P arts ▲ Replacement Danger and W ar ning labels, tags , and cards are av ailab le at no cost. V arying Parts ❖ Included with B-Side pump assemb ly . † In cluded with new pump assemblies (117, 118). Ref. P art Description Qty . 101 262465 PLA TE, motor 1 102 262466 ROD , tie, 4.00 long,1.0 0 dia 3 103 N65DN0 MO T OR, 6[...]
-
Page 46
Parts 46 3A0420H Air Contr ols, 258983 ✖ Not shown. 2 1. Apply anaerobic pipe sealant to all non-swiv eling pipe threads. Connect hose (214) to fitting (206) and air distr ibution manif old (213). 2 201 215 214 213 216 211 202 203 204 209 208 207 205 206 210 214 209 206 r_571100_3A0420A_1a- 1 Air Flo w Air Flow 211 TI17433a Ref. No. P art N o. De[...]
-
Page 47
Parts 3A0420H 47 Fluid Manif old, 258990 1. Apply anaerobic pipe sealant to all non-s wiveling pipe threads. T orque to 28-3 2 ft-lbs (38-43 N•m). Apply blue anaerobic adhesiv e to threads. Fur ther tighten either valv e (302) as required to line up handle straight across. Apply grease to spring ends. T orque to 70-9 0 in.-lbs (7.9-9 N•m). 2 3 [...]
-
Page 48
Recommended Spare Parts 48 3A0420H Recommended Spare P ar ts K eep these spar e par ts on hand to reduce downti me. Pump Repair Kits See page 11 to see what pumps ar e used on you r spra y er model. See lo wer manu al fo r repair kits. Pump Filter O-rings (packs of 10) 262483, T op o-ring 244895, Middle o- ring 262484, Bott om o-ring 262520, Recirc[...]
-
Page 49
Pump Performance Charts 3A0420H 49 Pump P erf ormance Char ts Calculate Fluid Outlet Pressure T o calculate fluid outlet pressure (psi/M P a/bar) at a spe- cific fluid flo w (gpm/lpm) and o perating air pr essure (psi/MP a/bar ), use the f ollowing inst ructions and pump data char ts. 1. Locate des ired flow along botto m of char t. 2. F ollow v er[...]
-
Page 50
Pump Performance Charts 50 3A0420H Pump P erf ormance Charts Continued Fluid Pressure in psig (MP a, bar) 1.5:1 Mix Ratio Ke y:Air Pressure A 80 psi (0.55 MP a, 55 bar) B 70 psi (0.5 MP a, 7.8 bar) C 40 psi (0.3 MP a, 2.8 bar) Air Flow in SCFM (m 3 /min) 200 (5.6) 180 (5) 160 (4.4) 140 (3.9) 120 (3.3) 100 (2.8) 80 (2.2) 60 (1.6) 40 (1.1) 20 (0.5) 8[...]
-
Page 51
Pump Performance Charts 3A0420H 51 Pump P erf ormance Charts Continued Fluid Pressure in ps ig (MP a, bar) 4:1 Mix Ratio Ke y:Air Pressure A 95 psi (0.65 MPa, 6.5bar) B 70 psi (0.5 MP a, 7.8 bar) C 40 psi (0.3 MP a, 2.8 bar) Air Flow in SCFM (m 3 /min) 200 (5.6) 180 (5) 160 (4.4) 140 (3.9) 120 (3.3) 100 (2.8) 80 (2.2) 60 (1.6) 40 (1.1) 20 (0.5) 800[...]
-
Page 52
Accessories and Kits 52 3A0420H Accessories and Kits Acceptable For Use in Explosive Atmospheres Blue 7 Gallon Hopper Kit, 24F376 Green 7 Gallon H opper Kit, 24F377 Mount to the sides of an XP70 spra y er . See manual 406860 f or m ore inf ormation. Solvent Pump Kit, 262393 F or supplying solv ent to the mix manif old. See ma nual 310863 f or m ore[...]
-
Page 53
Technical Data 3A0420H 53 Te c h n i c a l D a t a Vo l u m e Mix Ratio Pressure Ratio “A” Side Pump “B” Side Pump Combined Fluid Output cc/cycle Maximum Air W o rking Pressure psi (MP a, bar) Maximum F luid W o rking Pressure psi (MP a, psi) Flow Rate at 40 cyc les/min gpm (ltr/min) 1:1 76:1 Xtreme 85 Xtreme 85 173 95 (0.6, 6.5) 7250 (50, [...]
-
Page 54
Dimensions 54 3A0420H Dimensions 6.75 in. (171.45 mm) 16.90 in. (429.26 mm) 40 in. (1016 mm) 15.25 in. (387.35 mm) 22 in. (558.8 mm) 32 in. (812.8 mm) 32 in. (812.8 m m) 52 in. (1320.8 mm) 60 in. (1524 mm) r_571100_3a0420_10 1a r_571100_3a0420_100a 35 in. (889 mm) Full System Bare System To p V I e w Side VIew Floor Mounting Dimensions To p V I e w[...]
-
Page 55
Dimensions 3A0420H 55 Bare Pr opor tioner Mounting Hole Dimensions The dimensions belo w is the minimum openin g size f or mount ing a bare proportioner . 10.125 in. (257.175 mm) 5.06 in. (128.52 mm) 3.75 in. (95.25 mm ) 10.375 in. (263.525 mm) 3/8-16 (4x ) 7.5in. (190.5 mm) 14.35 in. (364.49 mm) 9.25 in. (234.95 mm) 0.25 in. (6.35 mm) 150° (4x) 1[...]
-
Page 56
All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. Original instructions. T his manual contains English. MM 3A0420 Graco Headquarters: Minneapoli s Internationa l Offices: Belgium, China, Japan,[...]