Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graham Field 14423-2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graham Field 14423-2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graham Field 14423-2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graham Field 14423-2 should contain:
- informations concerning technical data of Graham Field 14423-2
- name of the manufacturer and a year of construction of the Graham Field 14423-2 item
- rules of operation, control and maintenance of the Graham Field 14423-2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graham Field 14423-2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graham Field 14423-2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graham Field service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graham Field 14423-2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graham Field 14423-2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
14423-2 / 14423-4 / 14423-8 UL TRASOUND POCKE T DOPPLER USER MANUAL 14423-INS-LAB-RevD11 Impor tant: Do not use the Pocket Doppler without rst reading and understanding this manual! Save this manual for future use. FederalLaw(USA)restrictsthisdevicetosale byorontheorderofaphysician.Thisprodu[...]
-
Page 2
14423-INS-LAB-RevD1 1 2 CONTENTS 1 INTRODUCTION .........................................................................3 INTENDEDUSEOFTHISDEVICE ........................................ 3 INCLUDEDFEA TURES .......................................................... 3 OPTIONALACCESSORIES .........................[...]
-
Page 3
14423-INS-LAB-RevD1 1 3 1 INTR ODUCTION This user manual contains important information and safety pr ecautions for the Grafco Ultrasound Pocket Dop- pler . Before using the Pocket Doppler , please r ead and understand this entir e user manual. T ake special note of all safety pr ecautions that begin “W ARNING” and “CAUTION”. Save thi[...]
-
Page 4
14423-INS-LAB-RevD1 1 4 OPTIONALA CCESSORIES The following accessories for use with the Grafco Ultrason- ic Pocket Doppler ar e available from your GF Health Pr od- ucts, Inc. authorized distributor or www .grahameld.com. ItemNo. ProductDescription 4001GF Coupling Gel, case of 12 0.25 liter bottles 4002GF Coupling Gel, 5 liter bot[...]
-
Page 5
14423-INS-LAB-RevD1 1 5 2 SAFETYINFORMA TION SafetyGuidance This unit has internally powered equipment, and the degree of shock protection is type B T ype B protection means that this product is in accordance with permitted leakage currents and dielectric strengths of IEC 60601-1. SAFETYPRECA UTIONS The safety statements pr esented i[...]
-
Page 6
14423-INS-LAB-RevD1 1 6 WARNINGS W ARNING:FederalLaw(USA)restrictsthisdeviceto salebyorontheorderofaphysician.Thisproduct shouldnotbeusedunlesstheoperatorhasbeenin- structedbyaqualiedhealthcareprofessional. W ARNING:Donotuset[...]
-
Page 7
14423-INS-LAB-RevD1 1 7 W ARNING:DonottheusePocketDopplerifthebat- terycoverisopen. W ARNING:UseonlythoseprobesprovidedbyGF HealthProducts,Inc.intendedtobeusedwiththe GrafcoPocketDoppler . W ARNING:Donotstretchtheprobecable?[...]
-
Page 8
14423-INS-LAB-RevD1 1 8 NO TICES s NOTICE:ThemainunitoftheGrafcoPocketDoppler isdesignedforcontinuousnormaloperation.Donot immerseorsubmergeinanyliquid. s NOTICE:KeepthePocketDoppleranditsenviron- mentcleananddust-free.Protectthedevic[...]
-
Page 9
14423-INS-LAB-RevD1 1 9 SYMBOLS Attention: Refer to accompanying documents (this manual). This item is compliant with Medical Device Directive 93/42/ EEC of June 14, 1993, a directive of the European Economic Community . This symbol consisting of two parts, see below . Indicates that the equipment should be disposed of according to local regulat[...]
-
Page 10
14423-INS-LAB-RevD1 1 10 3 HANDLING GFHEAL THPRODUCTS,INC.FREIGHTPOLICY F ory ourpr otection,readcar efull y The carrier accepted this mer chandise “in good condition” and is r esponsible for safe deliver y . Before signing the fr eight bill, inspect the shipment carefully for damage or missing pieces. Appar ent[...]
-
Page 11
14423-INS-LAB-RevD1 1 1 1 Inspection Check the Pocket Doppler for nicks, dents, scratches, me- chanical or other damage. Check all the cables and acces- sories. ST ORAGE Stor e the repackaged Pocket Doppler in a dry area. s NOTICE:EnsurethatthetemperatureatthePocket Doppler'slocationduringstoragedoes?[...]
-
Page 12
14423-INS-LAB-RevD1 1 12 4 UL TRASOUNDPOCKETDOPPLER ANDA CCESSORIES APPEARANCEANDFEA TURES The following gur es illustrate the Pocket Doppler with the 2.0 MHz water-resistant pr obe, and accompanying tables describe labeled featur es. F rontPanel F ea tur e Function Display Panel Displays system info System status L[...]
-
Page 13
14423-INS-LAB-RevD1 1 13 Pow e r Button T urns the Ultrasound Pocket Doppler ON or OFF Probe Sock et The probe connects here to the Ultrasound Pocket Doppler Jack Denition 1 Power Supply 2 Signal 3 Probe Coding 1 4 Probe Coding 2 5 Probe Coding 3 6 (Shell) GND[...]
-
Page 14
14423-INS-LAB-RevD1 1 14 R earPanel F ea tur e Function P ock etClip Attachment Attaches Pocket Doppler to pocket Batter y Compar tment Opens to install/replace battery ProbeFrame Attaches probe to Pocket Doppler[...]
-
Page 15
14423-INS-LAB-RevD1 1 15 To p Panel F ea tur e Function Sock et Name Picture Function Charge Socket Not used Earphone Socket Connect earphone Signal Interface 1 GND 2 Signal 3 Signal 4 Signal 5 Signal War ning Refer to accompanying documents (this user manual) W ARNING: Accessoryequipmentconnectedtothe analoganddig[...]
-
Page 16
14423-INS-LAB-RevD1 1 16 LeftPanel F ea tur e Function V olumeControl Adjust volume Increase volume: Rotate volume knob clockwise Decrease volume: Rotate volume knob counter-clockwise MODEButton Not used ST ART/ST OPButton REC/PLA YButton[...]
-
Page 17
14423-INS-LAB-RevD1 1 17 POCKETDOPPLERWA TER-RESIST ANTPR OBES The 2.0 MHz, 4.0 MHz, and 8.0 MHz water-resistant pr obes connect to the main unit of the Grafco Pocket Doppler via the pr obe socket. The following table lists and describes the main information on each pr obe's label in or der of ap- pearance: P ock etDopplerWa [...]
-
Page 18
14423-INS-LAB-RevD1 1 18 5 SETUP INST ALLING OR REPLACING THE B A TTER Y W ARNING:EnsurethatPocketDopplerpowerisoff beforereplacingthebattery . W ARNING:Install/replacethebatteryatleast6feet (1.5meters)fromthepatient. W ARNING:Useonly9V?[...]
-
Page 19
14423-INS-LAB-RevD1 1 19 s NOTICE:Ifthebatteryterminalsbecomedirty ,wipe themwithaclean,dryclothbeforeusingthePocket Doppler . s NOTICE:Batterieshavelifecycles.Ifthebatteryuse timeshortensnoticeably ,thebattery'slifecycleis over [...]
-
Page 20
14423-INS-LAB-RevD1 1 20 6 OPERA TION PROBEOPERA TION R emo vingtheProbefr omthePoc k etDoppler s NOTICE:Donotdragordroptheprobe.Donotdis- connecttheprobefromthePocketDoppler . 1. The pr obe is installed in Pocket Doppler probe frame (left pictur e above). Hold the Po[...]
-
Page 21
14423-INS-LAB-RevD1 1 21 SwappingProbes s NOTICE:Donotdragordroptheprobeortheprobe connector . The Pocket Doppler is shipped with one pr obe connected. T o replace the connected pr obe with another Pocket Dop- pler pr obe: 1. Follow steps 1-3 in pr evious section, Removing the Pr obe fr om the Pocket Doppl[...]
-
Page 22
14423-INS-LAB-RevD1 1 22 FET ALHEART(FH)MONIT ORING FHMonitoringwith2.0MHzWa ter-R esistantProbe Refer to pictur e at right. The au- dio fetal heart beat is sent out via the built-in speaker or attached earphone. 1. Palpate for the fetus position to nd the best location to place the pr obe and hear the fetal heart r[...]
-
Page 23
14423-INS-LAB-RevD1 1 23 V ASCULAR MONIT ORING WITH 4.0 OR 8.0 MHZ PROBE (OPTIONAL) The 4.0 MHz and 8.0 MHz pr obes can be used to perform vascular monitoring assessment of blood ow . The 8.0 MHz pr obe is used for more supercial evaluation than the 4.0 MHz pr obe. Refer to the following probe site illustrat[...]
-
Page 24
14423-INS-LAB-RevD1 1 24 1. Apply a liberal amount of gel on the site to be exam- ined. 2. Place the pr obe so that the head is at least at 45º to the vessel to be examined. 3. Adjust the position of the pr obe to obtain the loudest audio signal. For best r esults, keep the probe as still as possible once the optimum position is located. 4. Adj[...]
-
Page 25
14423-INS-LAB-RevD1 1 25 7 MAINTENANCE W ARNING:Failureonthepartoftheresponsiblefacil- ityemployingtheuseofthisequipmenttoimplement asatisfactorymaintenanceschedulemaycauseun- dueequipmentfailureandpossiblehealthhazard. MAINTENANCE W ARNING:Befor[...]
-
Page 26
14423-INS-LAB-RevD1 1 26 s NOTICE:KeepthePocketDoppleranditsenviron- mentcleananddust-free.Protectthedevicefromvi- bration,corrosivemedicine,andhightemperatures. s NOTICE:Donotusehigh-temperaturesterilizingpro- cess,lowtemperaturesteam,E-beam,and[...]
-
Page 27
14423-INS-LAB-RevD1 1 27 CleaningtheP ock etDopplerPr obe s NOTICE:Donotallowliquidtoentertheultrasound system. s NOTICE:Donotpourliquidsontheprobewhile cleaning. The Pocket Doppler pr obe’ s acoustic surface is fragile and must be handled with car e. 1. T o prolong the [...]
-
Page 28
14423-INS-LAB-RevD1 1 28 DISINFECTION DisinfectingtheP ock etDopplerPr obe s NOTICE:Donotallowanyliquidtoentertheprobe socketwhiledisinfectingorimmersingtheprobe. 1. Clean the exterior surface of the pr obe as recommend- ed in the pr evious section. 2. T o disinfect the probe, immer[...]
-
Page 29
14423-INS-LAB-RevD1 1 29 8 SPECIFICA TIONS ModelNumber andName 14423-2 Ultrasonic Pocket Doppler with 2.0 MHz probe 14423-4 Ultrasonic Pocket Doppler with 4.0 MHz probe 14423-8 Ultrasonic Pocket Doppler with 8.0 MHz probe Safety Complies with: EN 60601-1/1990 Classication Anti-electric Shock T ype Internally powered equipment Anti[...]
-
Page 30
14423-INS-LAB-RevD1 1 30 Physical Characteristics Size (Width x Depth x Height) 3.35 x 1.26 x 5.43 inches (85 x 32 x 138 mm) Weight (including a battery and a probe) .64 lb (290 ±5g) En vironment Working T emperature 41°F ~ 104°F (5°C ~ 40°C) Humidity ≤80% RH Atmospheric Pressure 12.47 ~ 15.37 psi (86 ~ 106 kPa) T ransport and Storage [...]
-
Page 31
14423-INS-LAB-RevD1 1 31 Ultrasound Nominal Frequency 2.0 MHz W ater-Resistant Probe 2.0 MHz 4.0 MHz W ater-Resistant V ascular Probe 4.0 MHz 8.0 MHz W ater-Resistant V ascular Probe 8.0 MHz Working Frequency 2.0 MHz W ater-Resistant Probe 2.0 MHz ±10% 4.0 MHz W ater-Resistant V ascular Probe 4.0 MHz ±10% 8.0 MHz W ater-Resistant V ascular Pro[...]
-
Page 32
14423-INS-LAB-RevD1 1 32 9 LIMITEDWARRANTY GF Health Products Inc. warrants this pr oduct to be fr ee fr om manufacturing defects in material and workmanship for its period of warranty that is in accor dance with industr y standar ds. This warranty is extended only to the original pur chaser/consumer or dealer/non-consumer of this new pr o[...]
-
Page 33
14423-INS-LAB-RevD1 1 33 pur chaser’ s cost, for warranty inspection using the serial number as identication (or , if the product is not serialized, lot number and date code) within thirty (30) days of return authorization issue date. In the event you do not receive sat- isf act or y war ran ty service , plea se cont act GF Heal th Prod uct[...]
-
Page 34
14423-INS-LAB-RevD1 1 34 Thi s war rant y giv es you spec ic lega l righ ts and you may also have other legal rights which var y fr om state to state (pr ov- ince to province). Some states (pr ovinces) do not allow the ex clu sio n or limi tat io n of inci de nta l or con seq uen tia l dama ge, or limitation on how long an implied warranty la[...]
-
Page 35
14423-INS-LAB-RevD1 1 35 10 APPENDIXA,ECDECLARA TIONOF CONFORMITY ECDec lar ationof Confor mity Manufactured for GF Health Products, Inc., 2935 Northeast Parkway , Atlanta, GA 30360 Product Ultrasound Pocket Doppler Classication (MDD, Annex IX): IIa We herewith declare that the above mentioned product(s) meet the tr[...]
-
Page 36
14423-INS-LAB-RevD1 1 36 11 APPENDIXB ,EMCINFORMA TION GUID ANCEANDMANUF ACTURER’S DECLARA TION Electroma gneticEmissions—forallEquipment andSystems Guidanceandmanufacturer’sdec lar ation— electroma gneticemission The Grafco Ultrasound Pocket Doppler is intended for use in the electromagnet[...]
-
Page 37
14423-INS-LAB-RevD1 1 37 Electroma gneticImmunity—forallEquipment andSystems thatarenotLife-Suppor ting Guidanceandmanufacturer’sdec lar ation— electroma gneticimmunity The Grafco Ultrasound Pocket Doppler System is intended for use in the electromagnetic environment specied below . Do not use the sys[...]
-
Page 38
14423-INS-LAB-RevD1 1 38 Info 1: At 80 MHz and 800 MHz, the higher frequency range applies. Info 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from struc- tures, objects and people. a: Field strengths from xed transmitters, such as base stations for radio (cellular/c[...]
-
Page 39
14423-INS-LAB-RevD1 1 39 For transmitters rated at a maximum output power not listed previously , the recommended separation distances in meters (m) can be estimated using the equation applicable to the frequency of the transmitter , where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufactu[...]
-
Page 40
14423-INS-LAB-RevD1 1 40 12 APPENDIX C, O VERALL SENSITIVITY Ov er allSensitivity(2MHzProbe) Diameter of T arget Reector (mm) Distance (d) (mm) Reflection Loss A (d) T wo-way Attenuation B=∑B a +B w ∑B a (T :mm B a :dB) B w (dB) B (dB) 1.58 A=45.7dB @2 MHz 50 45.7 T 20 4.8 4.0 - 0 57.6 Ba 40 9.6 8.0 - 75 45.7 T [...]
-
Page 41
14423-INS-LAB-RevD1 1 41 Ov er allSensitivity(2MHzProbe) Diameter of T arget Reector (mm) V n (r .m.s.) mV V n (r .m.s.) mV dB Overall Sensitivity (S=A(d)+B+C) dB 1.58 A=45.7dB @2 MHz 186 94 5.93 109.2 175 90 5.78 107.8 174 89 5.82 107.9 173 90 5.68 100.9 2.38 A=43.2dB @2 MHz 178 89 6.02 1 10.0 170 90 5.52 107.1 165 85 5.76 105.3 [...]
-
Page 42
14423-INS-LAB-RevD1 1 42 13 INDEX A Accessories, optional 4 Accessory equipment, certica- tion of 6 Address, Graham-Field 34 Appendix A, EC Declaration of Conformity 35 Appendix B, EMC information 36 Appendix C, Overall Sensitivity 40 B Battery , installing / r eplacing 18 Battery terminals, cleaning 19 C CAUTION statement, signicance 5[...]
-
Page 43
14423-INS-LAB-RevD1 1 43 T T elephone number , Graham-Field 34 T op panel features and illustra- tion 15 U User manual, contents of 3 V V olume control 16 W WARNING statement, signi- cance 5 W arranty , limited 32[...]
-
Page 44
USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 www .grahamfield.com 14423-INS-LAB-RevD11 © 2011 GF Health Products, Inc.[...]