Greenheck Exhaust Fan SMD-302M manual

1
2
3
4
5
6
7

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Greenheck Exhaust Fan SMD-302M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Greenheck Exhaust Fan SMD-302M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Greenheck Exhaust Fan SMD-302M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Greenheck Exhaust Fan SMD-302M should contain:
- informations concerning technical data of Greenheck Exhaust Fan SMD-302M
- name of the manufacturer and a year of construction of the Greenheck Exhaust Fan SMD-302M item
- rules of operation, control and maintenance of the Greenheck Exhaust Fan SMD-302M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Greenheck Exhaust Fan SMD-302M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Greenheck Exhaust Fan SMD-302M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Greenheck service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Greenheck Exhaust Fan SMD-302M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Greenheck Exhaust Fan SMD-302M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Model SMD-302M meets the requir ements for smoke dampers established by: National Fire Pr otection Association NFP A Standards 92A, 92B, 101 & 105 IBC International Building Codes New Y ork City (MEA listing #260-91-M) CSFM California State Fire Marshal Leakage (Smoke) Damper Listing (#3230-0981:104) APPLICA TION Model SMD-302M is a leakage rat[...]

  • Page 2

    Pr essur e Dr op Data SMD-302M This pressur e drop testing was conducted in accor dance with AMCA Standard 500-D using the thr ee configurations shown. All data has been corrected to r epresent standar d air at a density of .075 lb/ft 3 (1.201 kg/m 3 ). Actual pressur e drop found in any HV AC system is a combination of many factors. This pressur e[...]

  • Page 3

    12x12 48x12 24x24 36x36 12x48 AMCA 5.2 Pr essur e Dr op SMD-302M 5D 6D 5D D 4 (W) (H) 3.14 Ve locity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) V elocity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) 500 0.03 500 0.01 500 0.01 500 0.01 500 0.02 1000 0.12 1000 0.06[...]

  • Page 4

    * Sizes are in inches. 12x12 48x12 12x48 24x24 36x36 AMCA 5.3 Pr essur e Dr op SMD-302M 5D 6D 5D D 4 (W) (H) 3.14 V elocity (fpm) Pressure Drop (in. wg) V e locity (fpm) Pressure Drop (in. wg) V e locity (fpm) Pressure Drop (in. wg ) V elocity (fpm) Pressure Drop (in. wg ) V elocity (fpm) Pressure Drop (in. wg) 500 0.01 500 0.01 500 0.01 500 0.01 5[...]

  • Page 5

    12x12 48x12 24x24 12x48 36x36 AMCA 5.5 Pr essur e Dr op SMD-302M 5D 6D 5D D 4 (W) (H) 3.14 V elocity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) Ve locity (fpm) Pressure Drop (in. wg) 500 0.04 500 0.03 50 0 0 .0 3 5 00 0.03 50 0 0 .03 1000 0.18 100[...]

  • Page 6

    Space Envelopes Required for Actuators and Accessories Externally mounted actuators always require space outside of the damper sideplate or sleeve. The “S” dimen- sion illustrates the clearance requir ed for various available actuators. On dampers less than 18 in. (457mm) high, actuators may also requir e clearances above and/or below the sidep[...]

  • Page 7

    50 in. 32 in. (813mm) 32 in. (813mm) 64 in. (1626mm) 50 in. 96 in. (2435mm) 50 in. 100 in. (1270mm) 32 in. (813mm) (2540mm) (1270mm) 32 in. (813mm) 128 in. (2540mm) (1270mm) 50 in. (1270mm) T ransitioned Damper Dimensions When a fire/smoke damper is being used in conjunction with r ound or oval ductwork, the SMD-302M can be supplied in a factory sl[...]