Grindmaster P300E manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Grindmaster P300E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Grindmaster P300E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Grindmaster P300E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Grindmaster P300E should contain:
- informations concerning technical data of Grindmaster P300E
- name of the manufacturer and a year of construction of the Grindmaster P300E item
- rules of operation, control and maintenance of the Grindmaster P300E item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Grindmaster P300E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Grindmaster P300E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Grindmaster service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Grindmaster P300E.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Grindmaster P300E item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Shuttle Bre wer & Airpot/Shuttle Bre wer s Operation and Instruction Manual F or Models P300E, P400E, RAP300E, RAP400E, RAPS300E, RAPS400E Installation: See rough-in dra wings in this manual f or dimensions and locations of electric and water input. Set-Up/P osition 1) Remov e the brew er from the packing material and attach its legs. 2) P osit[...]

  • Page 2

    Pag e 2 Shuttle Brewer s & Airpot/Shuttle Brewer s Installation (con't) Electric Hook-up 1) The electric ratings f or your bre wer are printed on its nameplate. T ypical electric ratings are: P300, P400, RAP300, RAP400 Optional 120/208V , 3.8kW , 18A or 120/240V 5.0kW , 21A, 1 phase Standard 120/208V , 5.0kW , 24A or 120/240V 6.6kW , 28A, [...]

  • Page 3

    Pag e 3 Operation 1) RAPS Brew ers require the accessor y warmer base placed ov er the pegs on the brew shelf bef ore brewing into a shuttle . Plug the base into the receptacle on the side of the brew er . The receptacle is only energized when a shuttle is in place . 2) Place an empty , warm shuttle or air pot on the shelf , counter , or accessor y[...]

  • Page 4

    Pag e 4 Adjustments All adjustable components are located under the top co v er . T o access these par ts: 1) Shut off the electric line to the brewer or unplug the bre wer . 2) Remov e the single screw f astening the top cov er . Remov e the top cov er . 3) Pull f orward and lift off the top co ver . Brew V olume , Brew Timer The brew v olume of t[...]

  • Page 5

    Pag e 5 Two Batch Timer with Knob Adjustment, See Figure 2: This timer is adjustable from 15 seconds to 5 min utes. Locate the adjustment knobs under the top cov er . Set this timer by adjusting the knob . The batch selector s witch picks the adjustment potentiometer which the timer will see. Figure 2 T wo Batch Timer Two Batch Timer with Counter A[...]

  • Page 6

    Pag e 6 T o Adjust the Bypass: 1) Shut off and open brew er as described at the beginning of the adjustments section. 2) Locate the bypass v alve f or the brew head you wish to adjust. V alve is on the right and front of the BREW v alve . 3) Open the v alve (counter cloc kwise) to the desired setting. Use the table belo w as a guide: BYP ASS SETTIN[...]

  • Page 7

    Pag e 7 4) If the maximum temperature adjustment needs to be increased, insert a small flat screwdriver into the shaft. T ur n the calibration screw counter cloc kwise to increase the maximum temperature . Optional Solid State Thermostat: This control maintains temperature within 3°F . The adjustable range is from 155°F to 205°F . See Figure 6. [...]

  • Page 8

    Pag e 8 Cleaning After Each Bre w: 1) Dispose of grounds and rinse brew bask et. 2) Rinse shuttle or air pot containers bef ore reuse. Every Day: 1) W ash brew basket with w ar m soap y water . The wire basket is remov able to aid cleaning. 2) Remov e spray head(s), located abo v e brew bask et(s), using glov es or a heavy to wel. W ash off coffee [...]

  • Page 9

    Pag e 9 W eekly or Bi-W eekly , Depending on Use 1) Fill shuttles with one gallon, 2/3 full, of hot water . 2) P our into the shuttle liners the recommended concentration of ur n cleaner (e xcessiv e amounts of cleaner will attack the stainless steel). Ur n cleaners that ha ve been used successfully: DIP-IT , manuf actured by Economics Labor atorie[...]

  • Page 10

    Pag e 1 0 Service (con't) Drain W ater T ank Alwa ys empty the tank before shipping. Note: Brew er ma y contain ov er 5 gallons of hot water . 1) Prepare a heat resistant container to drain tank w ater into . 2) Shut off pow er to the brewer . 3) Remov e the front access panel. 4) Pinch or clamp the silicone hose connected to fill v alve . 5) [...]

  • Page 11

    Pag e 1 1 T r oubleshooting: Filling, Heating, and Bre wing Overfilling water tank even when power is off. Fill valv e not sealing properly . Fill valv e installed backw ards. W ater entering tank continuously , usually slowly . Look f or direction of arrow on v alv e body . Disassemble v alve and clean out dir t. V alve ma y need new plunger if se[...]

  • Page 12

    Pag e 1 2 Shuttle Brewer s & Airpot/Shuttle Brewer s If you still need help, call our Technical Service Department at (502) 425-4776 or (800) 695-4500 (USA & Canada only) Monday thru Friday 8 am - 8 pm EST or an authorized service center in your area. Please have the model and serial numbers ready so that accurate information can be given. [...]

  • Page 13

    Pag e 1 3 T r oubleshooting: Filling, Heating, and Bre wing Brewing Pr oblems The brewing system consists of the f ollowing components: • Star t and Stop , switches located in the top control panel. • Brew Timer , located in the top control section under the top cover . • Brew V alv e, located in the top control section under the top cov er .[...]

  • Page 14

    Pag e 1 4 P ar ts Illustration for Models P300E & P400E Shuttle Brewer s & Airpot/Shuttle Brewer s Item Pa r t # Description Item Pa r t # Description 1 A545-034 LEG, 4” PLASTIC W/ SS FOOT 13 A725-081 BRASS SPRA Y TEE W/ BYP ASS TUBING 1 A545-015 LEG, 4” SS (OPTIONAL) 14 A530-009 BREW TIMER 0-8 MINUTES 2 A537-043 HO T W A TER F A UCET W[...]

  • Page 15

    Pag e 1 5 P ar ts Illustration for Model RAP400E Shuttle Brewer s & Airpot/Shuttle Brewer s Item Pa r t # Description Item Pa r t # Description 1 A548-072 LEG, R UBBER (RAP400) 11 A515016 PILO T LIGHT 1 A545-004 LEG, PLASTIC 4” (OPTIONAL RAP 400) 12 A725-082 SPRA Y TEE KIT W/ BYP ASS PLUG 1 A548-090 LEG, PLASTIC PLUG (RAP300) 13 A530-009 BREW[...]

  • Page 16

    Pag e 1 6 P ar ts Illustration for Model RAPS400E Shuttle Brewer s & Airpot/Shuttle Brewer s FR ONT Item Pa r t # Description Item Pa r t # Description 1 A545-034 LEG, 4” PLASTIC W/ SS FOOT 16 A725-081 BRASS SPRA Y TEE W/ BYP ASS TUBING 1 A545-015 LEG, 4” SS (OPTIONAL) 17 A585-021 SPRA Y TUBING 3/8” ID X 5/8”OD X 6”LG 2 A537-043 HO T [...]

  • Page 17

    Pag e 1 7 Shuttle Brewer s & Airpot/Shuttle Brewer s TOP (COVER REMOVED) FRONT FRONT (COVER REMOVED) 5 4 3 2 1 11 10 16 20 22 9 17 19 18 23 15 14 13 12 8 7 6 21 P ar ts Illustration for Model VSB-400 Item Pa r t # Description Item Pa r t # Description 1 A545-034 LEG, 4” PLASTIC W/ SS FOO T 12 A725-081 SPRA Y TEE KIT W/ BYP ASS TUBING 1 A545-0[...]

  • Page 18

    P ar ts Illustration for Shuttle CS-LL Item Pa r t # Description 1 A537-053 F A UCET MODEL ES 2 A522078 SHANK W/ CHROME BONNET 3 A718-018 GA UGE ASSEMBL Y 4 A725-092 KIT , SHUTTLE LID A713-027 SS SHUTTLE CO VER (not shown)* 5 A548-142 LID RET AINING CLIP 6 A548-140 A61365 LID ST OPPER W/ O-RING * S.S . Cover used until A ugust 2001 1 2 3 4 5 6 A537[...]

  • Page 19

    Pag e 1 9 Shuttle Brewer s & Airpot/Shuttle Brewer s Rough-In Drawing f or Model P-300[...]

  • Page 20

    Rough-In Drawing f or Model P-400 Pag e 2 0 Shuttle Brewer s & Airpot/Shuttle Brewer s[...]

  • Page 21

    Pag e 2 1 Shuttle Brewer s & Airpot/Shuttle Brewer s Rough-In Drawing f or Model RAP-300[...]

  • Page 22

    Rough-In Drawing f or Model RAP-400 Pag e 2 2 Shuttle Brewer s & Airpot/Shuttle Brewer s[...]

  • Page 23

    Pag e 2 3 Shuttle Brewer s & Airpot/Shuttle Brewer s Rough-In Drawing f or Model RAPS-300[...]

  • Page 24

    Pag e 2 4 Shuttle Brewer s & Airpot/Shuttle Brewer s Rough-In Drawing f or Model RAPS-400[...]

  • Page 25

    Pag e 2 5 Shuttle Brewer s & Airpot/Shuttle Brewer s Rough-In Drawing f or Model VSB-300 W W W W W A TER IM S[...]

  • Page 26

    Rough-In Drawing f or Model VSB-400 Pag e 2 6 Shuttle Brewer s & Airpot/Shuttle Brewer s[...]

  • Page 27

    Pag e 2 7 Shuttle Brewer s & Airpot/Shuttle Brewer s Wiring Diagram f or P300E/P400E, with 1 Batch Timer NO TE: THIS DRAWING SHO WS COMPONENTS ON ST ANDARD MODEL ONL Y . SEE 091-548 FOR WIRING OF BREWER OPTIONS[...]

  • Page 28

    Wiring Diagram f or P300E/P400E, with 2 Batch Timer NO TE: THIS DRAWING SHO WS COMPONENTS ON ST ANDARD MODEL ONL Y . SEE 091-548 FOR WIRING OF BREWER OPTIONS Pag e 2 8 Shuttle Brewer s & Airpot/Shuttle Brewer s[...]

  • Page 29

    Pag e 2 9 Shuttle Brewer s & Airpot/Shuttle Brewer s Wiring Diagram f or RAP300E/400E NO TE: THIS DRAWING SHO WS COMPONENTS ON ST ANDARD MODEL ONL Y . SEE 091-548 FOR WIRING OF BREWER OPTIONS Drawing #091-545[...]

  • Page 30

    Wiring Diagram f or RAPS 300/400E NO TE: 1) TWO SETS OF RECEPT ACLE COMPONENTS ONL Y PRO VIDED ON TWIN RAPS400E MODEL. DELETE GR OUP IN D ASHED BO X FOR RAPS300E. 2) THIS DIAGRAM SHO WS COMPONENTS ON ST AN- D ARD MODEL ONL Y . SEE 091-548 FOR WIRING OF BREWER OPTIONS. Drawing #091-523 Shuttle Brewer s & Airpot/Shuttle Brewer s Pag e 3 0[...]

  • Page 31

    Pag e 3 1 Shuttle Brewer s & Airpot/Shuttle Brewer s Wiring Diagram #091-548 NO TE: 1) ONE GROUP OF WARMER COMPONENTS PER BREW HEAD ON P AND RAPS MODELS. 2) TRANSFORMER MUST BE USED WHEN NEUTRAL LINE IS NO T PRO VIDED . 3) IF MODEL RAP , DELETE W ARMER COMPONENTS. 4) IF MODEL IS RAPS, DELETE WARMER LIGHT AND REPLACE W ARMER ELEMENT WITH NEMA 6-[...]

  • Page 32

    Wiring Diagram #091-182 T3 T3 T3 1 1 T4 A T2 T3 T3 T4 T4 T4 B T2 T3 T3 1 1 T1 C T3 T3 T3 T1 T1 T4 D T2 T3 T3 T1 T1 T4 E T2 T3 T3 T1 T1 T2 F NO TE: USE WIRE NUT FOR 1 - 1 CONNECTION 5000 W A TT / 240V HEA TERS * SEP ARA TE 120V REQUIRED FOR CONTR OLS (3 AMP LOAD) 2.0 KW - 120/208V - 1 PH - 3 WIRE - 9 AMPS 2.5 KW - 120/240V - 1 PH - 3 WIRE - 11 AMPS [...]

  • Page 33

    Pag e 3 3 Shuttle Brewer s & Airpot/Shuttle Brewer s Notes[...]

  • Page 34

    Pag e 3 4 Shuttle Brewer s & Airpot/Shuttle Brewer s Notes[...]

  • Page 35

    Pag e 3 5 Shuttle Brewer s & Airpot/Shuttle Brewer s Notes[...]

  • Page 36

    Grindmaster Corporation 4003 Collins Lane Louisville, KY 40245 USA (502) 425-4776 (800) 695-4500 F AX (502) 425-4664 www .grindmaster .com © Grindmaster Cor poration, 1995 PRINTED IN USA Shuttle Bre wer & Airpot/Shuttle Bre wer s W ARRANTY GENERAL W ARRANTY INFORMA TION Grindmaster Cor poration maintains the highest standard of quality control[...]