Go to page of
Similar user manuals
-
Portable Generator
Guardian Technologies 005243
72 pages 7.34 mb -
Humidifier
Guardian Technologies H2000
5 pages 0.14 mb -
Portable Generator
Guardian Technologies 004708-0
52 pages 1.73 mb -
Door
Guardian Technologies ACT2000
35 pages 0.87 mb -
Portable Generator
Guardian Technologies 5631
1 pages 0.78 mb -
Portable Generator
Guardian Technologies 5659
1 pages 0.65 mb -
Portable Generator
Guardian Technologies 005244
72 pages 7.34 mb -
Portable Generator
Guardian Technologies 005282
72 pages 7.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Guardian Technologies 17500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Guardian Technologies 17500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Guardian Technologies 17500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Guardian Technologies 17500 should contain:
- informations concerning technical data of Guardian Technologies 17500
- name of the manufacturer and a year of construction of the Guardian Technologies 17500 item
- rules of operation, control and maintenance of the Guardian Technologies 17500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Guardian Technologies 17500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Guardian Technologies 17500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Guardian Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Guardian Technologies 17500.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Guardian Technologies 17500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
[...]
-
Page 2
T able of Contents Commercial-Industrial-Residential Portable Generator System Safety Rules ..........................................1-3 Section 1 – General Information ....................4 1.1 Unpacking ....................................................................4 1.1.1 Accessory Box ..................................................4 [...]
-
Page 3
INTRODUCTION Thank you for purchasing this model of the GUARDIAN ® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage. READ THIS MAN[...]
-
Page 4
2 • Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator . • Do not insert objects through unit's cooling slots. • Never operate generato[...]
-
Page 5
ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure al[...]
-
Page 6
1.1 UNP ACKING • Set the palleted carton on a rigid flat surface. • Remove staples along bottom of carton that fasten carton to pallet. Open carton from top. • Remove all packaging material. • Remove separate accessory box. • Lift carton off the generator . • Remove generator from shipping pallet by removing bolts through the shipping b[...]
-
Page 7
5 1.2.3 BA TTERY CONNECTION • The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery . NOTE: A battery may lose some of it’ s charge when not in use for prolonged periods of time. • Cut the tie wrap cable holding the RED and BLACK batter y cables to the stator . • Connect th[...]
-
Page 8
6 Section 2 – Operation Commercial-Industrial-Residential Portable Generator System OPERA TION 2.1 KNOW THE GENERA TOR Read the Owner’ s Manual and Safety Rules before operating this generator . Compare the generator to this illustration to become familiarized[...]
-
Page 9
14) Start/Run/Stop Switch – Controls the operation of the generator . 15) Oil Fill – Use this point to add oil to engine. 16) Fuse - 10 Amp (Located at rear of control panel) – Protects the DC control circuit from overload. If this fuse element has melted open the engine will not be able to crank and start. 2.2 CORD SETS AND CONNECTION PLUGS [...]
-
Page 10
Figure 9 - 120 V AC, 30 Amp Receptacle Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker . 2.2.4 120/240V AC, 30 AMP RECEPT ACLE Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire grounde[...]
-
Page 11
2.3 HOW TO USE THE GENERA TOR If you have any problems operating your generator , please call the generator helpline at 1-800-333-1322. 2.3.1 GROUNDING THE GENERA TOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground . Local electrical [...]
-
Page 12
2.5 W A TT AGE REFERENCE GUIDE Device . . . . . . . . . . . . . . . . . . . . . . .Running Watts *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . .1700 *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . .3800 *Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . .6000 Battery Charger (20 Amp) . . . . . . . . . . . . [...]
-
Page 13
2.6.2 ADDING GASOLINE WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank. Caution: Do not overfill the fuel tank. Always leave room for fuel expansion. • Use regular UNLEADED gasoline with the generator engine. Do not use premium gasoline.[...]
-
Page 14
• Move engine CHOKE knob outward to “Full Choke” position. Figure 17 - Full Choke Position • T o start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position. • When the engine starts, move choke knob to “1/2[...]
-
Page 15
2.12 CHARGING A BA TTER Y DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious in[...]
-
Page 16
3.2.1 GENERA TOR SPECIFICA TIONS MODEL GPS 15,000 Model # 004582-2 Rated Max. Power 15.0 kW Surge Power 22.5 kW Rated AC Voltage 120/240 Rated Max AC Load Current @ 240V 62.5 Amps Current @ 120V 125.0 Amps Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase Rated DC Voltage 12 Volts Rated Max DC Load Current @ 12 Volts 10 Amperes 3.2.2 ENGINE SPECI[...]
-
Page 17
15 3.3 GENERAL RECOMMENDA TIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. T o receive full value from the warranty , the operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to properly maintain the generator . All adj[...]
-
Page 18
3.3.6 REPLACING THE SP ARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 1.01 mm (0.040 in.). Replace the plug once each year . This will help your engine start easier and run better . 1. Stop the engine and pull the spark plug wire off of the spark plug. 2. Clean the area around the spark plug and remove it from the cyl[...]
-
Page 19
Figure 21 - Spark Arrestor 3.6 ADJUSTING V AL VE CLEARANCE After the first 50 hours of operation, you should check the valve clearance in the engine and adjust if necessary . Important: If you feel uncomfortable about doing this procedure or you don't have the proper tools, please take your generator in to the nearest service center to have th[...]
-
Page 20
3.7 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage. DANGER! NEVER store engine with fuel in tank indoors or in enclosed, poorly ventila[...]
-
Page 21
19 4.1 TROUBLESHOOTING Engine is running, but no AC 1. Circuit breaker is open. 1. Reset circuit breaker . output is available. 2. Poor connection or defective cord set. 2. Check and repair . 3. Connected device is bad. 3. Connect another device that is in good condition. 4. Fault in generator . 4. Contact Authorized Ser vice Facility . Engine runs[...]
-
Page 22
20 Section 5 — Electrical Data Commercial-Industrial-Residential Portable Generator System Wiring Diagram, UltraSource Portable Generator – Drawing No. 0G0731 ACTUATOR ACTUATOR GOVERNOR GOVERNOR 4 0 CLOSEST TO BEARING STATOR 30 30 85 85 87a 87a 86 86 87 87 SC SC BLACK BLACK 12V 12V BATTERY BATTERY SM SM RED RED SP2 SP2 SP1 SP1 IM2 IM2 FSS FSS L[...]
-
Page 23
21 ACTUATOR GOVERNOR 4 0 CLOSEST TO BEARING CLOSEST TO BEARING STATOR STATOR 30 85 87a 86 87 SC BLACK 12V BATTERY SM RED SP2 SP1 IM2 FSS LOP D D IM1 STOP RUN (START) 0 IC PIN # 12 11 10 8 9 7 6 SCR 5 4 3 0 2 1 F1 GND SSR ENGINE WIRING 30A C.B. 22 C.B. 30A 0 22 22 G 0 0 TWISTLOK 120V/30A WHITE 22 0 0 G WHITE TWISTLOK 120V/30A 20A C.B. C.B. 20A C.B. [...]
-
Page 24
Section 5 — Electrical Data Commercial-Industrial-Residential Portable Generator System Schematic, UltraSource Portable Generator – Drawing No. 0G0733 86 86 0 14 14 15 15 15 15 167 167 0 17 17 16 16 13 13 13 13 22 22 44 44 ACTUATOR ACTUATOR J1 J1 44C 44C 0 RESET RESET TEST TEST GFCI GFCI 120V 120V 120V/30A 120V/30A TWISTLOK TWISTLOK CB1 - 10AMP[...]
-
Page 25
23 Section 6 - Notes Commercial-Industrial-Residential Portable Generator System[...]
-
Page 26
Section 6 - Notes Commercial-Industrial-Residential Portable Generator System 24[...]
-
Page 27
Section 6 - Notes Commercial-Industrial-Residential Portable Generator System 25[...]
-
Page 28
26 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System GT-990 Engine (Page 1) – Drawing No. 0E8589-R[...]
-
Page 29
27 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System GT-990 Engine (Page 1) – Drawing No. 0E8589-R ITEM PART NO. QTY. DESCRIPTION 1 0C5729 1 ASSEMBLY, CRANKCASE HOUSING WITH SLEEVE 2 0E9843 1 SEAL, 38 I.D. CRANKSHAFT 3 090388 3 SCREW, TAPTITE M6-1.0 X 12 BP 4 0C5372 1 ASSEMBLY, BREATHER 5 0C3[...]
-
Page 30
28 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System GT-990 Engine (Page 2) – Drawing No. 0E8589-R[...]
-
Page 31
29 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System GT-990 Engine (Page 2) – Drawing No. 0E8589-R ITEM PART # QTY. DESCRIPTION 66 0D6592 1 WINGNUT, AIRBOX 67 0D4511 1 PRECLEANER, AIR 68 0D9723 1 ELEMENT, AIR CLEANER 69 0E5302 1 STUD M6-1.0 X 73 70 0D4183 1 ADAPTOR, SPIT BACK 71 0D6327 1 GASK[...]
-
Page 32
30 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Generator – Drawing No. 0G0742-A[...]
-
Page 33
31 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Generator – Drawing No. 0G0742-A ITEM PART NO. QTY. DESCRIPTION 1 0C6934 1 ADAPTOR, ENGINE 2 0G1177 1 STATOR 15KW 0D2136 STATOR 17.5KW 3 0G11760SRV 1 ASSEMBLY, ROTOR WITH FAN 15KW 0D21350SRV ASSEMBLY, ROTOR WITH FAN 17.5KW 4 0C6043B 1 CARRI[...]
-
Page 34
32 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Control Panel – Drawing No. 0G0727-B[...]
-
Page 35
ITEM P ART NO. QTY . DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET , 12VDC SNAP 3 0D6640 1 COVER, GOVERNOR CONTROL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D8740 1 PANEL, SHEET MET AL (15 KW) 0G0309 1 P ANEL, SHEET MET AL (17.5 KW) 6 068868 2 OUTLET 30A 120V RECEPT 7 0G1093 4 SCREW SFILHM #8-32 X 5/8 LG (17.5 KW ONL Y) 8 043182 4 WASHER L[...]
-
Page 36
Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Frame, Handle & Wheel Kit – Drawing No. 0E0695-B 34[...]
-
Page 37
35 ITEM P ART NO. QTY . DESCRIPTION 1 057058 4 SCREW HHC M6-1.0 X 55 2 0D5315 4 RUBBER T ANK MOUNT 3 0D4570 1 CAP , FUEL WITH GAUGE & VENT 4 0D22850SRV 1 KIT , FUEL T ANK 5 045771 4 NUT HEX M8-1.25 6 022129 10 WASHER LOCK M8-5/16 7 022145 14 WASHER FLA T 5/16 8 0D4565 1 BRACKET BA TTERY 9 0D3545 2 BOL T ,BA TTERY J-BOL T 10 022287 2 SCREW HHC 1[...]
-
Page 38
36 CALIFORNIA EMISSION CONTROL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The Calif or nia Air Resources Board (CARB) and Generac P ow er Systems, Inc. (Gener ac) are pleased to explain the Emission Control System warr anty on your new engine . In Calif or nia, new off-road Large Spark-Ignition (LSI) engines must be designed, bui[...]
-
Page 39
37 EMISSION CONTROL SYSTEM W ARRANTY Emission Control System W arranty (ECS warranty) f or 2001 and later model year LSI engines: (a) Applicability: This warranty shall apply to 2001 and later model y ear engines. The ECS Warranty period shall begin on the date the ne w engine or equipment is purchased by/deliv ered to its original, end-use purchas[...]
-
Page 40
Section 8 – Warranty Commercial-Industrial-Residential Portable Generator System Part No. 0G1086 Rev . A Printed in U.S.A. 6/2 9 /06 GENERAC POWER SYSTEMS “TWO YEAR” LIMITED W ARRANTY FOR GUARDIAN ® “15,000 W A TT PORT ABLE GENERA TOR” For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrant[...]